Safety Analysis of All-Inside Arthroscopic Repair of Peripheral Triangular Fibrocartilage Complex

被引:15
|
作者
Waterman, Scott M. [1 ]
Slade, Dirk [2 ]
Masini, Brendan D. [3 ]
Owens, Brett D. [4 ]
机构
[1] Walter Reed Natl Mil Med Ctr, Bethesda, MD 20889 USA
[2] William Beaumont Army Med Ctr, El Paso, TX 79920 USA
[3] San Antonio Mil Med Ctr, San Antonio, TX USA
[4] Keller Army Community Hosp, West Point, NY USA
关键词
DORSAL SENSORY BRANCH; PARTIAL EXCISION; ARTICULAR DISK; ISOLATED TEARS; ULNAR NERVE; WRIST; MANAGEMENT; ANATOMY; INJURY;
D O I
10.1016/j.arthro.2010.02.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to determine whether an all-inside peripheral triangular fibrocartilage complex (TFCC) repair using the FasT-Fix device (Smith & Nephew Endoscopy, Andover, MA) is safe by measuring the proximity of the anchors to ulnar-sided anatomic structures. Methods: Eleven fresh-frozen cadaveric wrists were thawed and placed in traction. Under direct arthroscopic visualization, an all-inside arthroscopic peripheral TFCC repair was completed by placing a single FasT-Fix device in a vertical mattress fashion. The wrists were then dissected to visualize the 2 anchors. The distance between these anchors and the flexor carpi ulnaris (FCU), extensor carpi ulnaris (ECU), and dorsal branch of the ulnar sensory nerve (DBUN) were measured with digital calipers and recorded. Results: The peripheral anchor averaged 4.2 mm (range, 0 to 14 mm) from the ECU tendon, 3.8 mm (range, 0 to 9 mm) from the DBUN, and 8.3 mm (range, 1 to 15 mm) from the FCU tendon. The central anchor averaged 9.6 mm (range, 2 to 15 mm) from the ECU tendon, 6.8 mm (range, 1 to 13 mm) from the DBUN, and 7.6 mm (range, 1 to 13 mm) from the FCU tendon. Conclusions: This study exposes some safety concerns with the all-inside peripheral TFCC repair using the FasT-Fix device, which was found to reside in close proximity to the ECU, FCU, and DBUN. In multiple wrists the anchors were noted to underlie the anatomic structure that we measured, making it possible to pierce these structures with the needle before deployment of the anchor. Clinical Relevance: Though technically feasible, all-inside arthroscopic repair of the peripheral TFCC risks injury to the ulnar-sided anatomy.
引用
收藏
页码:1474 / 1477
页数:4
相关论文
共 50 条
  • [41] Preliminary experience of fully arthroscopic repair of triangular fibrocartilage complex lesions
    Conca, M
    Conca, R
    Dalla Pria, A
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (07):
  • [42] Arthroscopic Repair of Ulnar-Sided Triangular Fibrocartilage Complex Tears
    Micucci, Chad J.
    Schmidt, Christopher C.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2007, 17 (02) : 118 - 124
  • [43] Open versus arthroscopic repair of the triangular fibrocartilage complex: a systematic review
    Andersson J.K.
    Åhlén M.
    Andernord D.
    Journal of Experimental Orthopaedics, 5 (1)
  • [44] Vascular safety during arthroscopic all-inside meniscus suture
    Nishimura, Akinobu
    Fukuda, Aki
    Kato, Ko
    Fujisawa, Kohzo
    Uchida, Atsumasa
    Sudo, Akihiro
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (04) : 975 - 980
  • [45] Arthroscopic one-tunnel transosseous foveal repair for triangular fibrocartilage complex (TFCC) peripheral tear
    Ji Hun Park
    Dongmin Kim
    Jong Woong Park
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 131 - 138
  • [46] Arthroscopic one-tunnel transosseous foveal repair for triangular fibrocartilage complex (TFCC) peripheral tear
    Park, Ji Hun
    Kim, Dongmin
    Park, Jong Woong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (01) : 131 - 138
  • [47] Early isolated triangular fibrocartilage complex tears: Management by arthroscopic repair
    Shih, JT
    Lee, HM
    Tan, CM
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 53 (05): : 922 - 927
  • [48] All-Arthroscopic Foveal Triangular Fibrocartilage Complex Tendon Reconstruction
    Tang, Camelia Q. Y.
    Jiang, Jackson K. H.
    Chin, Andrew Y. H.
    Choudhury, Muntasir M.
    JOURNAL OF WRIST SURGERY, 2024, 13 (01) : 58 - 65
  • [49] RETRACTED ARTICLE: Prognostic factors for the outcome of arthroscopic capsular repair of peripheral triangular fibrocartilage complex tears
    Young Hak Roh
    Yeo-Hon Yun
    Dong Jun Kim
    Muhyun Nam
    Hyun Sik Gong
    Goo Hyun Baek
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 1741 - 1746
  • [50] Results of arthroscopic repair of triangular fibrocartilage complex peripheral tears (Palmer type 1B)
    Kabakas, Fatih
    Ozcelik, Ismail Bulent
    Ugurlar, Meric
    Mersa, Berkan
    Yazar, Memet
    Uzun, Metin
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2014, 20 (03): : 205 - 210