Comparative study between volar locked plates versus closed reduction with percutaneous pinning in management of unstable extra-articular distal radius fractures

被引:1
|
作者
Al-Shahwanii, Zaid Wajeh [1 ]
Qaryaqos, Saher Habeeb [2 ]
机构
[1] Mustansiriyah Univ, Coll Med, Dept Surg, Baghdad, Iraq
[2] Univ Mosul, Coll Med, Dept Trauma & Orthoped Surg, Baghdad, Iraq
关键词
Distal radius fracture; Percutaneous K. wires; Volar locked plate; AO classification of distal radius; LOCKING PLATE; FIXATION; OUTCOMES; EPIDEMIOLOGY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Unstable extra articular fractures of distal radius need operative treatment, either by manipulation and closed pinning by K-wires, or by locked types of plates that give good anatomical restoration. Objective: To compare the volar locked plate versus manipulation and percutaneous pinning method of fixations for unstable extra articular fractures of distal radius. Methods: A prospective comparative study was conducted on 26 patients with mean age of 48.42 +/- 10.7 years having closed, unilateral, unstable extra articular distal radius fracture according to the one or more of the following criteria; (dorsal displacement >= 20 degrees, metaphyseal dorsal comminution, age >= 60 years, ulnar fracture, initial displacement >= 1cm, radial shortening >= 5 mm). Patients were divided in two treatment groups, thirteen were fixed with k-wires and thirteen with volar locked plate. The follow up visit was scheduled after 3 months after surgery to assess the union and functional outcomes using Modified Mayo score and Quick DASH score at 3 months postoperatively and then up to 6th months to assess clinical outcomes and complications for each case. Results: No significant difference in time of union was observed in both groups, but better functional outcome was seen in the locked plate group compared to the K-wire group. The total infection rate, was 4(30.76 %) patients for wire group and one (7.70%) patient for plate group, mal-union was seen in 4(30.70%) patients in wire group and one (7.70%) patient in the plate group, tendonitis was encountered in one (7.70%) patient in wire group and 3(23.08%) patients in the plate group. Painful hardware was noted in one (7.70%) patient in the wire group and 2(15.40%) patients in the plate group. Re-operation was required in 2(15.40%) patients in wire group and one (7.70 %) patients in the plate group. Conclusion: In distal radius extra articular unstable fracture, volar locked plate provides a superior functional outcome, less complications compared to closed percutaneous k-wires pinning.
引用
收藏
页码:S35 / S39
页数:5
相关论文
共 50 条
  • [21] Percutaneous pins versus volar plates for unstable distal radius fractures: A biomechanical study using a cadaver model.
    Knox, I
    Trumble, TE
    Ambrose, H
    McCallister, W
    JOURNAL OF INVESTIGATIVE MEDICINE, 2005, 53 (01) : S163 - S163
  • [22] Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate
    Tarallo L.
    Mugnai R.
    Adani R.
    Catani F.
    Journal of Orthopaedics and Traumatology, 2014, 15 (4) : 285 - 290
  • [23] How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates?
    Jung, Hyoung-Seok
    Jung, Han Sol
    Baek, Suk-Ho
    Lee, Jae Sung
    CLINICS IN ORTHOPEDIC SURGERY, 2020, 12 (01) : 22 - 28
  • [24] Percutaneous pinning versus volar locking plate internal fixation for unstable distal radius fractures: a meta-analysis
    Peng, Fei
    Liu, Yuan-xiang
    Wan, Zhen-yu
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (02) : 158 - 167
  • [25] Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: Biomechanical comparison with a volar locking plate
    Strauss, Eric J.
    Banerjee, Devraj
    Kummer, Frederick J.
    Tejwani, Nirmal C.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (04): : 975 - 981
  • [26] Treatment of unstable distal phalanx fractures by extra-articular DIP pinning: A series of 12 cases
    Prunieres, G.
    Gouzou, S.
    Facca, S.
    Matheron, A. -S.
    Maire, N.
    Diaz, J. -J. Hidalgo
    Liverneaux, P.
    HAND SURGERY & REHABILITATION, 2016, 35 (05): : 330 - 334
  • [27] Methodological issues of: Should unstable extra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial
    Gomez-Rice, Alejandro
    Villarrubia, Elena
    Bau, Alonso
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (07): : 1219 - 1219
  • [28] Sonography for monitoring closed reduction of displaced extra-articular distal radial fractures
    Chern, TC
    Jou, IM
    Lai, KA
    Yang, CY
    Yeh, SH
    Cheng, SC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (02): : 194 - 203
  • [29] Necessity of acceptable radiologic alignment by preoperative closed reduction for unstable distal radius fractures treated with volar locking plates
    Jung, Hyoung-Seok
    Chun, Kwang-Jin
    Kim, Jae Yoon
    Lee, Jae-Sung
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2021, 47 (06) : 1881 - 1887
  • [30] Necessity of acceptable radiologic alignment by preoperative closed reduction for unstable distal radius fractures treated with volar locking plates
    Hyoung-Seok Jung
    Kwang-Jin Chun
    Jae Yoon Kim
    Jae-Sung Lee
    European Journal of Trauma and Emergency Surgery, 2021, 47 : 1881 - 1887