Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: Biomechanical comparison with a volar locking plate

被引:11
|
作者
Strauss, Eric J. [1 ]
Banerjee, Devraj [1 ]
Kummer, Frederick J. [1 ]
Tejwani, Nirmal C. [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthoped Surg, New York, NY 10003 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2008年 / 64卷 / 04期
关键词
biomechanics; distal radius fracture; external fixation; volar locked plate;
D O I
10.1097/TA.0b013e3180eea9f0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures. Methods: A simulated, unstable, extra-articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator (Mirza Cross Pin Fixator (CPX), A.M. Surgical Inc. Smithtown, NY] and the other was treated with a volar locked plate [Distal Volar Radial Plate (DVR), Hand Innovations, Miami, FL]. Each specimen was axially loaded in central, dorsal, and volar locations, loaded in cantilever bending in volar to dorsal, dorsal to volar, and radial to ulnar directions and loaded in torsion. Load-displacement curves were generated to determine the construct stiffness for each loading schema, with comparisons made between the two treatment groups. Specimens were then cyclically loaded with 50 N axial loads applied for 1,000 and 10,000 cycles. Measurement of construct stiffness was repeated and comparisons made both between the two treatments and within treatments to their precycling stiffness. Results: There was no significant difference in the mechanical stiffness of the nonspanning external fixator and the volar locking plate after axial loading in any of the loading modalities. Cyclic loads of 1,000 and 10,000 cycles resulted in no significant difference in construct stiffness between the nonspanning external fixator and volar locked plate. However, the nonspanning external fixator demonstrated decreasing stiffness after cyclic loading with 10,000 cycles (p < 0.02). Conclusion: This study demonstrated no significant difference in the mechanical stiffness of the CPX nonspanning external fixator and volar locked plate in a cadaveric fracture model. Both constructs appear to be biomechanically equivalent in this experimental model; however, this is only one factor in the choice of fixation device for the management of unstable distal radius fractures.
引用
收藏
页码:975 / 981
页数:7
相关论文
共 50 条
  • [1] Biomechanical evaluation of the stability of extra-articular distal radius fractures fixed with volar locking plates according to the length of the distal locking screw
    Oh, Gyung-Hwan
    Kim, Hak-Sung
    Lee, Jung Il
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (08) : 922 - 932
  • [2] Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate
    Tarallo L.
    Mugnai R.
    Adani R.
    Catani F.
    Journal of Orthopaedics and Traumatology, 2014, 15 (4) : 285 - 290
  • [3] Treatment of unstable distal radius fractures with the volar locking plate
    Minegishi, Hanae
    Dohi, Osamu
    An, Soukan
    Sato, Hidetsugu
    UPSALA JOURNAL OF MEDICAL SCIENCES, 2011, 116 (04) : 280 - 284
  • [4] Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures
    Kumbaraci M.
    Kucuk L.
    Karapinar L.
    Kurt C.
    Coskunol E.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (2) : 173 - 178
  • [5] Volar fixation for dorsally angulated extra-articular fractures of the distal radius: A biomechanical study
    Koh, Shukuki
    Morris, Randal P.
    Patterson, Rita A.
    Kearney, J. Patrick
    Buford, William L., Jr.
    Viegas, Steven F.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (05): : 771 - 779
  • [6] Treatment of extra-articular and simple articular distal radial fractures with intramedullary nail versus volar locking plate
    Safi, A.
    Hart, R.
    Teknedzjan, B.
    Kozak, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38 (07) : 774 - 779
  • [7] Treatment of unstable extra-articular distal radius fractures using locked volar plating and percutaneous pinning without external fixation
    Joni, Saeid Sadeghi
    Yavari, Pedram
    Tavakoli, Peyman
    Tavoosi, Pedram
    Mohammadsharifi, Ghasem
    INTERNATIONAL JOURNAL OF BURNS AND TRAUMA, 2020, 10 (04): : 113 - 120
  • [8] Volar locking plate fixation of unstable distal radius fractures
    Kilic, Ayhan
    Kabukcuoglu, Yavuz
    Ozkaya, Ufuk
    Gul, Murat
    Sokucu, Sami
    Ozdogan, Umit
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 303 - 308
  • [9] Volar Locking Plate Versus Dorsal Locking Nail-Plate Fixation for Dorsally Displaced Unstable Extra-Articular Distal Radial Fractures
    Eikrem, Morten
    Brannsten, Hege
    Bjorkoy, Dagfinn
    Lian, Tom
    Madsen, Jan Erik
    Figved, Wender
    JBJS OPEN ACCESS, 2021, 6 (04)
  • [10] HEALING OF EXTRA-ARTICULAR ANGULATED APEX VOLAR FRACTURES OF THE DISTAL RADIUS
    ROTH, JH
    MINIACI, A
    CANADIAN JOURNAL OF SURGERY, 1988, 31 (01) : 39 - 41