Treatment of unstable extra-articular distal radius fractures using locked volar plating and percutaneous pinning without external fixation

被引:3
|
作者
Joni, Saeid Sadeghi [1 ]
Yavari, Pedram [2 ]
Tavakoli, Peyman [3 ]
Tavoosi, Pedram [4 ]
Mohammadsharifi, Ghasem [2 ]
机构
[1] Guilan Univ Med Sci, Razi Hosp, Dept Radiol, Rasht, Iran
[2] Isfahan Univ Med Sci, Dept Orthoped Surg, Sch Med, Hezar Jarib St, Esfahan 6516675349, Isfahan, Iran
[3] Univ Tehran Med Sci, Sch Med, Tehran, Iran
[4] Islamic Azad Univ, Dept Civil Engn, Khorasgan Isfahan Branch, Sch Engn, Esfahan, Iran
来源
关键词
Fixing fracture; radius fracture; surgery methods; INTERNAL-FIXATION; OPEN REDUCTION; LOCKING PLATE; COMPLICATIONS; PARAMETERS;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: One of the most common fractions is distal radius fracture, and various treatments have been suggested for this. The purpose of this study, is comparison of Open reduction and internal fixation by using a locked volar plating compared to percutaneous pinning by cast immobilization under the elbow in patients less than 60 years with good bone density that had unstable extra-articular distal radius fracture or UDRF. Methods: This study was clinical trial. 88 patients with closed UDRF who were referred for surgical treatment entered the study. Patients were randomized into two groups: group 1 had open reduction and internal fixation by using a locked volar plating and the other group had percutaneous pinning by cast immobilization surgeries. Amount of pain [by using Visual analog scale or VAS] and functional results of two methods were compared 3 and 12 month after surgeries. Findings: The intensity of pain was higher in the pinning group 3 and 12 month after treatment (P=0.001 and P=0.390 respectively). The range of motions in the plating group was significantly better (P<0.001). There was a significant difference in performing daily activities 3 month after treatment between the two groups, but a significant limitation in daily activities, observed 12 months after surgery in pinning group (P=0.004). Conclusion: Bone fixation, using locked volar plating, can be a better modality with regard to postsurgical pain and also the wrist range of motion than percutaneous pinning with cast immobilization in patients younger than 60 years sustaining unstable, closed extra-articular, distal radius fracture.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 50 条
  • [1] Comparative study between volar locked plates versus closed reduction with percutaneous pinning in management of unstable extra-articular distal radius fractures
    Al-Shahwanii, Zaid Wajeh
    Qaryaqos, Saher Habeeb
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2021, 71 (12) : S35 - S39
  • [2] Percutaneous pinning for non-comminuted extra-articular fractures of distal radius
    Das, Abhishek K.
    Sundaram, Nandkumar
    Prasad, Thiruvengita G.
    Thanhavelu, Suresh K.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (05) : 422 - 426
  • [3] Volar fixation for dorsally angulated extra-articular fractures of the distal radius: A biomechanical study
    Koh, Shukuki
    Morris, Randal P.
    Patterson, Rita A.
    Kearney, J. Patrick
    Buford, William L., Jr.
    Viegas, Steven F.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (05): : 771 - 779
  • [4] Comparison of five percutaneous pinning methods for unstable extra-articular distal radius fractures: A mechanical study using sawbones
    Muratli, S. Kivanc
    Uzun, Bora
    Celik, Salih
    JOINT DISEASES AND RELATED SURGERY, 2021, 32 (01): : 51 - 58
  • [5] Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: Biomechanical comparison with a volar locking plate
    Strauss, Eric J.
    Banerjee, Devraj
    Kummer, Frederick J.
    Tejwani, Nirmal C.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (04): : 975 - 981
  • [6] HEALING OF EXTRA-ARTICULAR ANGULATED APEX VOLAR FRACTURES OF THE DISTAL RADIUS
    ROTH, JH
    MINIACI, A
    CANADIAN JOURNAL OF SURGERY, 1988, 31 (01) : 39 - 41
  • [7] External Fixation Versus Open Reduction With Locked Volar Plating for Geriatric Distal Radius Fractures
    Lee, Daniel J.
    Elfar, John C.
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2014, 5 (03) : 141 - 143
  • [8] Unstable extra-articular fractures of the distal radius - A prospective, randomised study of immobilisation in a cast versus supplementary percutaneous pinning
    Azzopardi, T
    Ehrendorfer, S
    Coulton, T
    Abela, M
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (06): : 837 - 840
  • [9] Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: A biomechanic study
    McCall, Todd A.
    Conrad, Bryan
    Badman, Brian
    Wright, Thomas
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (06): : 806 - 812
  • [10] Treatment of complex fractures of the distal radius: A prospective randomised comparison of external fixation 'versus' locked volar plating
    Jeudy, J.
    Steiger, V.
    Boyer, P.
    Cronier, P.
    Bizot, P.
    Massin, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (02): : 174 - 179