Comparative study between volar locked plates versus closed reduction with percutaneous pinning in management of unstable extra-articular distal radius fractures

被引:1
|
作者
Al-Shahwanii, Zaid Wajeh [1 ]
Qaryaqos, Saher Habeeb [2 ]
机构
[1] Mustansiriyah Univ, Coll Med, Dept Surg, Baghdad, Iraq
[2] Univ Mosul, Coll Med, Dept Trauma & Orthoped Surg, Baghdad, Iraq
关键词
Distal radius fracture; Percutaneous K. wires; Volar locked plate; AO classification of distal radius; LOCKING PLATE; FIXATION; OUTCOMES; EPIDEMIOLOGY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Unstable extra articular fractures of distal radius need operative treatment, either by manipulation and closed pinning by K-wires, or by locked types of plates that give good anatomical restoration. Objective: To compare the volar locked plate versus manipulation and percutaneous pinning method of fixations for unstable extra articular fractures of distal radius. Methods: A prospective comparative study was conducted on 26 patients with mean age of 48.42 +/- 10.7 years having closed, unilateral, unstable extra articular distal radius fracture according to the one or more of the following criteria; (dorsal displacement >= 20 degrees, metaphyseal dorsal comminution, age >= 60 years, ulnar fracture, initial displacement >= 1cm, radial shortening >= 5 mm). Patients were divided in two treatment groups, thirteen were fixed with k-wires and thirteen with volar locked plate. The follow up visit was scheduled after 3 months after surgery to assess the union and functional outcomes using Modified Mayo score and Quick DASH score at 3 months postoperatively and then up to 6th months to assess clinical outcomes and complications for each case. Results: No significant difference in time of union was observed in both groups, but better functional outcome was seen in the locked plate group compared to the K-wire group. The total infection rate, was 4(30.76 %) patients for wire group and one (7.70%) patient for plate group, mal-union was seen in 4(30.70%) patients in wire group and one (7.70%) patient in the plate group, tendonitis was encountered in one (7.70%) patient in wire group and 3(23.08%) patients in the plate group. Painful hardware was noted in one (7.70%) patient in the wire group and 2(15.40%) patients in the plate group. Re-operation was required in 2(15.40%) patients in wire group and one (7.70 %) patients in the plate group. Conclusion: In distal radius extra articular unstable fracture, volar locked plate provides a superior functional outcome, less complications compared to closed percutaneous k-wires pinning.
引用
收藏
页码:S35 / S39
页数:5
相关论文
共 50 条
  • [41] Volar versus dorsal plating in the management of intra-articular distal radius fractures
    Ruch, DS
    Papadonikolakis, A
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (01): : 9 - 16
  • [42] Biomechanical Analysis of Volar and Dorsal Double Locking Plates for Fixation in Comminuted Extra-articular Distal Radius Fractures: A 3D Finite Element Study
    Lin, Yu-Hao
    Lin, Chun-Li
    Kuo, Hsien-Nan
    Sun, Ming-Tsung
    Chen, Alvin Chao-Yu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (05) : 349 - 355
  • [43] Conservative treatment of extra-articular Colles' type fractures of the distal radius: Prospective study
    Smilovic, J
    Bilic, R
    CROATIAN MEDICAL JOURNAL, 2003, 44 (06) : 740 - 745
  • [44] External Fixation Versus Open Reduction With Locked Volar Plating for Geriatric Distal Radius Fractures
    Lee, Daniel J.
    Elfar, John C.
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2014, 5 (03) : 141 - 143
  • [45] Intramedullary nail versus volar plate fixation of extra-articular distal radius fractures. Two year results of a prospective randomized trial
    Gradl, Gertraud
    Mielsch, Nadja
    Wendt, Martina
    Falk, Steffi
    Mittlmeier, Thomas
    Gierer, Philip
    Gradl, Georg
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 : S3 - S8
  • [46] Dorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial
    Chappuis, J.
    Boute, P.
    Putz, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (05) : 471 - 478
  • [47] Volar Locking Plate Versus Dorsal Locking Nail-Plate Fixation for Dorsally Displaced Unstable Extra-Articular Distal Radial Fractures
    Eikrem, Morten
    Brannsten, Hege
    Bjorkoy, Dagfinn
    Lian, Tom
    Madsen, Jan Erik
    Figved, Wender
    JBJS OPEN ACCESS, 2021, 6 (04)
  • [48] Comparative study between intramedullary interlocking nailing and minimally invasive percutaneous plate osteosynthesis for distal tibia extra-articular fractures
    Mani, Kapil K. C.
    Pangeni, Bandhu Ram
    Marahatta, Suman Babu
    Sigdel, Arun
    Amuda, K. C.
    CHINESE JOURNAL OF TRAUMATOLOGY, 2022, 25 (02) : 90 - 94
  • [49] Comparative study between intramedullary interlocking nailing and minimally invasive percutaneous plate osteosynthesis for distal tibia extra-articular fractures
    KC Kapil Mani
    Pangeni Bandhu Ram
    Marahatta Suman Babu
    Sigdel Arun
    KC Amuda
    中华创伤杂志(英文版), 2022, (02) : 90 - 94
  • [50] A Novel Method of Closed Reduction and Percutaneous Pinning With Six K-wires for Intra-articular Fractures of the Distal Radius
    Vidyadharan, Anilkumar
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS, 2020, 4 (06):