Comparison between Modified and Unmodified Carbon Paste Electrodes for Hexavalent Chromium Determination

被引:21
|
作者
Hilali, Nazha [1 ]
Ghanam, Abdelghani [1 ]
Mohammadi, Hasna [1 ]
Amine, Aziz [1 ]
Jose Garcia-Guzman, Juan [2 ]
Cubillana-Aguilera, Laura [2 ]
Maria Palacios-Santander, Jose [2 ]
机构
[1] Hassan II Univ Casablanca, Fac Sci & Tech, Lab Genie Proc & Environm, BP 146, Mohammadia 20800, Morocco
[2] Univ Cadiz, Dept Analyt Chem, Fac Sci, Inst Res Electron Microscopy & Mat IMEYMAT,Campus, Campus Univ Puerto Real,Polgono Rio San Pedro S-N, Cadiz 11510, Spain
关键词
Carbon paste electrodes; Diphenylcarbazide; Gold nanoparticles; Hexavalent chromium; Speciation; STRIPPING VOLTAMMETRIC MEASUREMENTS; SOLID-PHASE EXTRACTION; GOLD NANOPARTICLES; ELECTROCHEMICAL DETECTION; WATER SAMPLES; CR(VI); SPECIATION; IONS; INTERFERENCES; NANOCOMPOSITE;
D O I
10.1002/elan.201800505
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work consists of developing a simple electroanalytical method which allows the speciation of Cr(VI). Gold modified Carbon Paste Electrodes (CPEs) and unmodified CPEs have been tested for the determination of Cr(VI) in presence of an excess of Cr(III) by using differential pulse voltammetry (DPV), without any accumulation or pre-concentration time. Several parameters affecting the analytical performances of the designed electrodes were investigated, including: electrodeposition technique of AuNPs onto the CPE, amount of AuNPs dropped on the electrode surface, supporting electrolyte, presence of Cr(III), presence of chloride ions and concentration of diphenylcarbazide (DPC). Under the optimal conditions, the use of unmodified CPE in an acidic medium containing DPC exhibited a high selectivity and a good detection limit of 19 mu g L-1, which is much lower than the admissible concentration fixed by the World Health Organization (50 mu g.L-1). A linear range from 50 to 260 mu g.L-1 was obtained with a relative standard deviation of 7.75 %. Furthermore, as opposed to the AuNPs-modified CPE, the current response of Cr(VI) obtained at the unmodified CPE was not affected by the presence of chloride ions and trivalent chromium. Finally, the proposed method was successfully applied for the determination of Cr(VI) in real tap water samples with satisfactory results.
引用
收藏
页码:2750 / 2759
页数:10
相关论文
共 50 条
  • [41] PRECONCENTRATION AND DETERMINATION OF BENTAZEPAM AT C18-MODIFIED CARBON PASTE ELECTRODES
    HERNANDEZ, P
    LORENZO, E
    CERRADA, J
    HERNANDEZ, L
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (4-5): : 429 - 432
  • [42] CHEMICALLY MODIFIED CARBON PASTE AND CARBON COMPOSITE ELECTRODES
    STARA, V
    KOPANICA, M
    ELECTROANALYSIS, 1989, 1 (03) : 251 - 256
  • [43] Carbon paste electrodes electrochemically modified with cyclodextrins
    Morales, GR
    Silva, TR
    Galicia, L
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2003, 7 (06) : 355 - 360
  • [44] Carbon paste electrodes electrochemically modified with cyclodextrins
    Gabriela Roa Morales
    Teresa Ramírez Silva
    Laura Galicia
    Journal of Solid State Electrochemistry, 2003, 7 : 355 - 360
  • [45] Determination of Chromium(VI) in Electronics Materials Using Trioctylamine Modified Carbon Paste Electrode
    Xu, Juan
    Kong, Yong
    Wang, Wenchang
    Chen, Zhidong
    Yao, Shiping
    ANALYTICAL SCIENCES, 2009, 25 (12) : 1427 - 1430
  • [46] Determination of Chromium(VI) in Electronics Materials Using Trioctylamine Modified Carbon Paste Electrode
    Juan Xu
    Yong Kong
    Wenchang Wang
    Zhidong Chen
    Shiping Yao
    Analytical Sciences, 2009, 25 : 1427 - 1430
  • [47] Amperometric determination of rutin on carbon paste electrodes
    Macikova, Pavla
    Hrbac, Jan
    Halouzka, Vladimir
    Skopalova, Jana
    JOURNAL OF BIOCHEMICAL TECHNOLOGY, 2010, 2 (05) : S20 - S21
  • [48] AMPEROMETRIC DETERMINATION OF RUTIN ON CARBON PASTE ELECTRODES
    Macikova, Pavla
    Hrbac, Jan
    Halouzka, Vladimir
    Skopalova, Jana
    X PRACOVNI SETKANI FYZIKALNICH CHEMIKU A ELECTROCHEMIKU/ 10TH WORKSHOP OF PHYSICAL CHEMISTS AND ELECTROCHEMISTS, 2010, : 147 - 149
  • [49] Electrochemical reduction of hexavalent chromium ions from leachate of leather industrial waste using a modified carbon paste electrode
    Mohanraj, P.
    Bhuvaneshwari, S.
    Amala, J.
    Aravind, S. P.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2023, 20 (06) : 6161 - 6174
  • [50] Electrochemical reduction of hexavalent chromium ions from leachate of leather industrial waste using a modified carbon paste electrode
    P. Mohanraj
    S. Bhuvaneshwari
    J. Amala
    S. P. Aravind
    International Journal of Environmental Science and Technology, 2023, 20 : 6161 - 6174