Determination of Chromium(VI) in Electronics Materials Using Trioctylamine Modified Carbon Paste Electrode

被引:6
|
作者
Xu, Juan [1 ,2 ]
Kong, Yong [1 ]
Wang, Wenchang [1 ]
Chen, Zhidong [1 ]
Yao, Shiping [3 ]
机构
[1] Jiangsu Polytech Univ, Qualtec Co Ltd, Changzhou 213164, Peoples R China
[2] Jiangsu Fine Petr Chem Key Labs, Changzhou 213164, Peoples R China
[3] ChemChina Petr Dev Corp, Beijing 100080, Peoples R China
基金
美国国家科学基金会;
关键词
HEXAVALENT CHROMIUM; STRIPPING VOLTAMMETRY; CR(VI); REDUCTION; ELECTROCOAGULATION; EXTRACTION; SEPARATION; SPECIATION; REMOVAL; IONS;
D O I
10.2116/analsci.25.1427
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A trioctylamine (TOA) modified carbon paste electrode (TOA/CPE) was firstly utilized to determine Cr(VI) in electronics materials. The effects of preconcentration conditions, that is, TOA amount and accumulation time on Cr(VI) accumulation were examined and the optimum experiment conditions for the determination were identified. A sensitive reduction peak in the stripping voltammogram at 0.45 V, a characteristic of trace Cr(VI), was detected when the accumulation time was 10 min. Under optimized conditions, TOA/CPE demonstrated an enhanced sensitivity for Cr(VI), providing a low detection limit (S/N = 3) at 3.4 x 10(-9) M. Interference studies also displayed high selectivity of the TOA/CPE for Cr(VI); this electrode can accurately determine Cr(VI) in the presence of Cr(III) (600-fold concentration) and other interfering cations.
引用
收藏
页码:1427 / 1430
页数:4
相关论文
共 50 条
  • [1] Determination of Chromium(VI) in Electronics Materials Using Trioctylamine Modified Carbon Paste Electrode
    Juan Xu
    Yong Kong
    Wenchang Wang
    Zhidong Chen
    Shiping Yao
    [J]. Analytical Sciences, 2009, 25 : 1427 - 1430
  • [2] DETERMINATION OF CHROMIUM(VI) AND CHROMIUM(III) BY USING A DIPHENYLCARBAZIDE-MODIFIED CARBON PASTE ELECTRODE
    PANIAGUA, AR
    VAZQUEZ, MD
    TASCON, ML
    BATANERO, PS
    [J]. ELECTROANALYSIS, 1993, 5 (02) : 155 - 163
  • [3] USING CHROMIUM MODIFIED CARBON PASTE ELECTRODE FOR HEAVY METAL IONS DETERMINATION
    Koudelkova, Zuzana
    Zawrotna, Natalia
    Jelinkova, Pavlina
    Richtera, Lukas
    Adam, Vojtech
    [J]. PROCEEDINGS OF INTERNATIONAL PHD STUDENTS CONFERENCE, (MENDELNET 2016), 2016, : 994 - 998
  • [4] Highly sensitive potentiometry for determination of chromium(VI) with carbon paste electrode
    Hu, XY
    Leng, ZZ
    [J]. ANALYTICAL PROCEEDINGS, 1995, 32 (12): : 521 - 522
  • [5] An oxidative procedure for the electrochemical determination of chromium(VI) using modified carbon paste electrodes
    Sánchez-Fernández, ME
    Cubillana-Aguilera, LM
    Palacios-Satander, JM
    Naranjo-Rodríguez, I
    de Cisneros, JLHH
    [J]. BULLETIN OF ELECTROCHEMISTRY, 2005, 21 (12): : 529 - 535
  • [6] A Novel Modified Carbon Paste Electrode for the Determination of Chromium(III) in Water
    Heidari, Zahra
    Masrournia, Mahboubeh
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (08) : 824 - 831
  • [7] A study on the determination of chromium as chromate at a carbon paste electrode modified with surfactants
    Svancara, I
    Foret, P
    Vytras, K
    [J]. TALANTA, 2004, 64 (04) : 844 - 852
  • [8] A Novel Modified Carbon Paste Electrode for the Determination of Chromium(III) in Water
    [J]. Journal of Analytical Chemistry, 2018, 73 : 824 - 831
  • [9] A Novel Modified Carbon Paste Electrode for the Determination of Chromium(III) in Water
    [J]. Mahboubeh Masrournia (mah.masrour@gmail.com), 1600, Pleiades journals (73):
  • [10] Voltammetric determination of Chromium(VI) using a gold film modified carbon composite electrode
    Kachoosangi, Roohollah Torabi
    Compton, Richard G.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 555 - 562