Comparison between Modified and Unmodified Carbon Paste Electrodes for Hexavalent Chromium Determination

被引:21
|
作者
Hilali, Nazha [1 ]
Ghanam, Abdelghani [1 ]
Mohammadi, Hasna [1 ]
Amine, Aziz [1 ]
Jose Garcia-Guzman, Juan [2 ]
Cubillana-Aguilera, Laura [2 ]
Maria Palacios-Santander, Jose [2 ]
机构
[1] Hassan II Univ Casablanca, Fac Sci & Tech, Lab Genie Proc & Environm, BP 146, Mohammadia 20800, Morocco
[2] Univ Cadiz, Dept Analyt Chem, Fac Sci, Inst Res Electron Microscopy & Mat IMEYMAT,Campus, Campus Univ Puerto Real,Polgono Rio San Pedro S-N, Cadiz 11510, Spain
关键词
Carbon paste electrodes; Diphenylcarbazide; Gold nanoparticles; Hexavalent chromium; Speciation; STRIPPING VOLTAMMETRIC MEASUREMENTS; SOLID-PHASE EXTRACTION; GOLD NANOPARTICLES; ELECTROCHEMICAL DETECTION; WATER SAMPLES; CR(VI); SPECIATION; IONS; INTERFERENCES; NANOCOMPOSITE;
D O I
10.1002/elan.201800505
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work consists of developing a simple electroanalytical method which allows the speciation of Cr(VI). Gold modified Carbon Paste Electrodes (CPEs) and unmodified CPEs have been tested for the determination of Cr(VI) in presence of an excess of Cr(III) by using differential pulse voltammetry (DPV), without any accumulation or pre-concentration time. Several parameters affecting the analytical performances of the designed electrodes were investigated, including: electrodeposition technique of AuNPs onto the CPE, amount of AuNPs dropped on the electrode surface, supporting electrolyte, presence of Cr(III), presence of chloride ions and concentration of diphenylcarbazide (DPC). Under the optimal conditions, the use of unmodified CPE in an acidic medium containing DPC exhibited a high selectivity and a good detection limit of 19 mu g L-1, which is much lower than the admissible concentration fixed by the World Health Organization (50 mu g.L-1). A linear range from 50 to 260 mu g.L-1 was obtained with a relative standard deviation of 7.75 %. Furthermore, as opposed to the AuNPs-modified CPE, the current response of Cr(VI) obtained at the unmodified CPE was not affected by the presence of chloride ions and trivalent chromium. Finally, the proposed method was successfully applied for the determination of Cr(VI) in real tap water samples with satisfactory results.
引用
收藏
页码:2750 / 2759
页数:10
相关论文
共 50 条
  • [31] CHEMICALLY MODIFIED CARBON PASTE ELECTRODES
    BALDWIN, RP
    BUCHANAN, RM
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1984, 131 (08) : C329 - C329
  • [32] DETERMINATION OF CHROMIUM(VI) AND CHROMIUM(III) BY USING A DIPHENYLCARBAZIDE-MODIFIED CARBON PASTE ELECTRODE
    PANIAGUA, AR
    VAZQUEZ, MD
    TASCON, ML
    BATANERO, PS
    ELECTROANALYSIS, 1993, 5 (02) : 155 - 163
  • [33] USING CHROMIUM MODIFIED CARBON PASTE ELECTRODE FOR HEAVY METAL IONS DETERMINATION
    Koudelkova, Zuzana
    Zawrotna, Natalia
    Jelinkova, Pavlina
    Richtera, Lukas
    Adam, Vojtech
    PROCEEDINGS OF INTERNATIONAL PHD STUDENTS CONFERENCE, (MENDELNET 2016), 2016, : 994 - 998
  • [34] Study of electrochemical determination of capsaicin and dihydrocapsaicin at carbon paste electrodes modified by β-cyclodextrin
    de Leon Zavala, Elena Diaz
    Torres Rodriguez, Luz Maria
    Montes-Rojas, Antonio
    Torres Mendoza, Victor Hugo
    Linan Gonzalez, Alejandra Elizabeth
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 814 : 174 - 183
  • [35] DETERMINATION OF IRON(II) WITH CHEMICALLY-MODIFIED CARBON-PASTE ELECTRODES
    GAO, ZQ
    LI, PB
    ZHAO, ZF
    TALANTA, 1991, 38 (10) : 1177 - 1184
  • [36] Electrochemical characterization and determination of mercury using carbon paste electrodes modified with cyclodextrins
    Roa-Morales, G
    Ramírez-Silva, MT
    González, RL
    Galicia, L
    Romero-Romo, M
    ELECTROANALYSIS, 2005, 17 (08) : 694 - 700
  • [37] Electrocatalytic determination of vitamin C using calixarene modified carbon paste electrodes
    Ijeri, VS
    Algarra, M
    Martins, A
    ELECTROANALYSIS, 2004, 16 (24) : 2082 - 2086
  • [38] Carbon nitride nanoparticles modified carbon paste electrodes as potentiometric sensors for determination of nickel(II) and chromium(III) ions in tap water samples
    Soheyla Sharif Manesh
    Mahboubeh Masrournia
    Journal of the Iranian Chemical Society, 2021, 18 : 1219 - 1229
  • [39] Carbon nitride nanoparticles modified carbon paste electrodes as potentiometric sensors for determination of nickel(II) and chromium(III) ions in tap water samples
    Sharif Manesh, Soheyla
    Masrournia, Mahboubeh
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2021, 18 (05) : 1219 - 1229
  • [40] Potentiometric determination of oxybutynin hydrochloride in pharmaceutical formulations at modified carbon paste electrodes
    Mostafa, Maysa R.
    Mohamed, Gehad G.
    Mohamed, Marwa E.
    Frag, Eman Y. Z.
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2020, 59 (03): : 324 - 332