Experimental Evaluation of the Shear Resistance of Corrugated Perfobond Rib Shear Connections

被引:35
|
作者
Kim, Sang-Hyo [1 ]
Ahn, Jin-Hee [1 ]
Choi, Kyu-Tae [1 ]
Jung, Chi-Young [1 ]
机构
[1] Yonsei Univ, Dept Civil & Environm Engn, Seoul 120749, South Korea
关键词
shear behavior; corrugated perfobond rib; perfobond rib; shear connector; shear resistance; push-out test; BEHAVIOR; STEEL;
D O I
10.1260/1369-4332.14.2.249
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Push-out tests were carried out to examine the shear strength of corrugated perfobond rib shear connections. The corrugated perfobond rib shear connection, formed by folding the straight perfobond rib steel panel, can be expected to increase the shear capacity and ductility of a shear connector due to the shear resistance and deformation of the inclined rib panel. To examine the shear behaviour of the corrugated perfobond rib connection and compare it with that of the perfobond rib, the push-out specimens were fabricated to suit the shear corrugated rib resistance parameters of depth of rib, height of rib, holes in the corrugated rib and whether transverse rebar is placed in the corrugated rib holes. Results of the push-outs show that the failure of corrugated perfobond rib shear connection is determined by concrete bearing and small deformations of inclined perfobond rib panel. Specifically, the corrugated rib specimens showed different relative slips at each side of the composite interface owing to the stress flow along the inclined rib developed by inclined direction of the welded corrugated perfobond rib. The transverse rebar in the rib hole reduced the difference in relative slips. The shear strength of the corrugated connection is increased by about 198 similar to 512% compared with the standard perfobond rib specimen connection with transverse rebars and without transverse rebars respectively. However, the contribution of other shear resistance parameters is found to be relatively small compared with the contribution provided by transverse rebars in the rib holes. In terms of the ductility of the shear connector, the relative slip of the corrugated rib connections increased after ultimate load, so it is evaluated to have a sufficient ductility.
引用
收藏
页码:249 / 263
页数:15
相关论文
共 50 条
  • [31] Experimental research on shear behavior of multiple Perfobond rib shear connectors in steel-concrete composite girder
    Xue, Weichen
    Yan, Dawei
    Dai, Yan
    Wang, Wei
    STRUCTURES, 2025, 71
  • [32] Development of Shear Resistance Formula for the Y-Type Perfobond Rib Shear Connector Considering Probabilistic Characteristics
    Kim, Sang-Hyo
    Batbold, Tuvshintur
    Shah, Syed Haider Ali
    Yoon, Suro
    Han, Oneil
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [33] Theory model of shear transferring for perfobond rib connector
    Su, Qingtian
    Xu, Yuanchun
    Wang, Wei
    Tongji Daxue Xuebao/Journal of Tongji University, 2013, 41 (12): : 1775 - 1780
  • [34] Modeling the cyclic response of perfobond-rib shear connectors
    Kisaku, Tomoaki
    Fujiyama, Chikako
    3RD INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS - SUSTAINABLE STRUCTURES FOR FUTURE GENERATIONS, 2017, 171 : 1317 - 1324
  • [35] An experimental study on the shear strength of FRP perfobond shear connector
    Gwon, S. C.
    Kim, S. H.
    Yoon, S. J.
    Choi, C. W.
    2018 INTERNATIONAL CONFERENCE ON MATERIAL STRENGTH AND APPLIED MECHANICS (MSAM 2018), 2018, 372
  • [36] Shear Behavior of Perfobond Rib Shear Connectors for Pre-fabricated Composite Bridges
    装配式组合梁桥开孔钢板连接件抗剪性能
    2018, Chang'an University (31):
  • [37] Shear Behavior of Y-Shaped Perfobond Rib Shear Connector with UHPC Grout
    Ni, Yulong
    Hu, Menghan
    Jia, Zhenlei
    Han, Qiang
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (09)
  • [38] Push-out tests and evaluation of FRP perfobond rib shear connectors performance
    Kolpasky, Ludvik
    Ryjacek, Pavel
    BUILDING UP EFFICIENT AND SUSTAINABLE TRANSPORT INFRASTRUCTURE 2017 (BESTINFRA2017), 2017, 236
  • [39] Influence of transverse rebar on shear behavior of Y-type perfobond rib shear connection
    Kim, Sang-Hyo
    Kim, Kun-Soo
    Han, Oneil
    Park, Jun-Seung
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 180 : 254 - 264
  • [40] Theoretical and Experimental Studies of the Internal Force Transfer Mechanism of Perfobond Rib Shear Connector Group
    Zhang, Qinghua
    Pei, Shiling
    Cheng, Zhenyu
    Bao, Yi
    Li, Qiao
    JOURNAL OF BRIDGE ENGINEERING, 2017, 22 (02)