Experimental Evaluation of the Shear Resistance of Corrugated Perfobond Rib Shear Connections

被引:35
|
作者
Kim, Sang-Hyo [1 ]
Ahn, Jin-Hee [1 ]
Choi, Kyu-Tae [1 ]
Jung, Chi-Young [1 ]
机构
[1] Yonsei Univ, Dept Civil & Environm Engn, Seoul 120749, South Korea
关键词
shear behavior; corrugated perfobond rib; perfobond rib; shear connector; shear resistance; push-out test; BEHAVIOR; STEEL;
D O I
10.1260/1369-4332.14.2.249
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Push-out tests were carried out to examine the shear strength of corrugated perfobond rib shear connections. The corrugated perfobond rib shear connection, formed by folding the straight perfobond rib steel panel, can be expected to increase the shear capacity and ductility of a shear connector due to the shear resistance and deformation of the inclined rib panel. To examine the shear behaviour of the corrugated perfobond rib connection and compare it with that of the perfobond rib, the push-out specimens were fabricated to suit the shear corrugated rib resistance parameters of depth of rib, height of rib, holes in the corrugated rib and whether transverse rebar is placed in the corrugated rib holes. Results of the push-outs show that the failure of corrugated perfobond rib shear connection is determined by concrete bearing and small deformations of inclined perfobond rib panel. Specifically, the corrugated rib specimens showed different relative slips at each side of the composite interface owing to the stress flow along the inclined rib developed by inclined direction of the welded corrugated perfobond rib. The transverse rebar in the rib hole reduced the difference in relative slips. The shear strength of the corrugated connection is increased by about 198 similar to 512% compared with the standard perfobond rib specimen connection with transverse rebars and without transverse rebars respectively. However, the contribution of other shear resistance parameters is found to be relatively small compared with the contribution provided by transverse rebars in the rib holes. In terms of the ductility of the shear connector, the relative slip of the corrugated rib connections increased after ultimate load, so it is evaluated to have a sufficient ductility.
引用
收藏
页码:249 / 263
页数:15
相关论文
共 50 条
  • [21] Shear Resistance Assessment of the Y-Type Perfobond Rib Shear Connector under Repeated Loadings
    Kim, Sang-Hyo
    Han, Oneil
    Yoon, Suro
    Boldoo, Tuguldur
    APPLIED SCIENCES-BASEL, 2021, 11 (16):
  • [22] Experimental study on shear performance of twin perfobond rib shear connectors under monotonic and repeated loading
    Deng W.
    Liu D.
    Gu J.
    Zhang J.
    Hu J.
    1600, Science Press (38): : 342 - 348
  • [23] Shear Strength of T-type Perfobond Rib Shear Connectors
    Chung, Chul Hun
    Lee, Jungwhee
    Kim, Jong Suk
    KSCE JOURNAL OF CIVIL ENGINEERING, 2016, 20 (05) : 1824 - 1834
  • [24] Shear strength of T-type Perfobond rib shear connectors
    Chul Hun Chung
    Jungwhee Lee
    Jong Suk Kim
    KSCE Journal of Civil Engineering, 2016, 20 : 1824 - 1834
  • [25] Ultimate Shear Resistance of Perfobond Rib Shear Connectors Based on a Modified Push-Out Test
    Wang, Zhenhai
    Li, Qiao
    Zhao, Canhui
    ADVANCES IN STRUCTURAL ENGINEERING, 2013, 16 (04) : 667 - 680
  • [26] Experimental shear strength evaluation of perfobond shear connector with various hole shapes
    Zheng, Shuangjie
    Zhao, Chen
    Liu, Yuqing
    STRUCTURAL ENGINEERING AND MECHANICS, 2018, 67 (02) : 131 - 142
  • [27] Experimental evaluation of the structural response of Perfobond shear connectors
    Candido-Martins, J. P. S.
    Costa-Neves, L. F.
    Vellasco, P. C. G. da S.
    ENGINEERING STRUCTURES, 2010, 32 (08) : 1976 - 1985
  • [28] Shear behaviour of perfobond rib shear connector under static and cyclic loadings
    Ahn, J. -H.
    Kim, S. -H.
    Jeong, Y. -J.
    MAGAZINE OF CONCRETE RESEARCH, 2008, 60 (05) : 347 - 357
  • [29] Applications of Hybrid System with Perfobond Rib Shear Connectors
    Kim, S. -H.
    Jung, C. -Y.
    Joung, J. -Y.
    Ahn, J. -H.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 2525 - 2533
  • [30] Experiment on shear transferring mechanics of perfobond rib connector
    Su, Qingtian
    Li, Chenxiang
    Wang, Wei
    Tongji Daxue Xuebao/Journal of Tongji University, 2013, 41 (11): : 1623 - 1629