Push-out tests and evaluation of FRP perfobond rib shear connectors performance

被引:3
|
作者
Kolpasky, Ludvik [1 ]
Ryjacek, Pavel [1 ]
机构
[1] Czech Tech Univ, Thakurova 7, Prague 16629 6, Czech Republic
关键词
CONCRETE;
D O I
10.1088/1757-899X/236/1/012069
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The behavioural characteristics of FRP (fibre-reinforced polymer) perfobond rib shear connector was examined through push-out tests in order to verify the applicability for pedestrian bridge structure. The aim of this study is to determine interaction between high performance concrete slab and handmade FRP plate which represent web of the composite beam. Combination of these modern materials leads to structural system with both great load bearing capacity and also sufficient flexural stiffness of the composite element. Openings cut into the GFRP plate at a variable spacing allow GFRP reinforcement bars to be inserted to act as shear studs. Hand lay-up process can increase suitable properties of FRP for connection by perfobond rib shear connectors. In this study, three push-out tests on fiber-reinforced polymer were performed to investigate their shear behaviour. The results of the push-out tests on FRP perfobond rib shear connector indicates great promise for application in full scale structures.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] BEHAVIOR OF PERFOBOND RIB SHEAR CONNECTORS - PUSH-OUT TESTS
    VELDANDA, MR
    HOSAIN, MU
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1992, 19 (01) : 1 - 10
  • [2] Behaviour of perfobond-rib shear connectors. Push-out tests
    Veldanda, M.R.
    Hosain, M.U.
    Proceedings - Annual Conference and 1st Biennial Environmental Speciality Conference, 1990, 4 pt 2
  • [3] Numerical analysis of push-out specimens with perfobond rib connectors
    Oguejiofor, EC
    Hosain, MU
    COMPUTERS & STRUCTURES, 1997, 62 (04) : 617 - 624
  • [4] Ultimate Shear Resistance of Perfobond Rib Shear Connectors Based on a Modified Push-Out Test
    Wang, Zhenhai
    Li, Qiao
    Zhao, Canhui
    ADVANCES IN STRUCTURAL ENGINEERING, 2013, 16 (04) : 667 - 680
  • [5] Study on the shear performance of adhesive shear connectors in push-out tests
    Zhan, Yulin
    Duan, Mengjun
    Zhang, Lei
    Liu, Chudong
    Li, Zhaoyu
    Zhao, Renda
    STRUCTURES, 2021, 32 : 2103 - 2117
  • [6] Push-out tests on adhesively bonded perfobond shear connectors for timber-concrete composite beams
    Appavuravther, Elif
    Vandoren, Bram
    Henriques, Jose
    JOURNAL OF BUILDING ENGINEERING, 2022, 57
  • [7] Numerical Analysis for Push-Out Test with Y Type Perfobond Shear Connectors
    Mefleh, Wajdi
    Kovács, Nauzika
    ce/papers, 2022, 5 (04) : 800 - 808
  • [8] Shear behaviours of steel-HSFRC welded stud and perfobond rib connectors under static push-out experiments
    Wu, Fangwen
    Tang, Wenlong
    Liu, Shuo
    Fan, Zhou
    Yang, Fei
    STRUCTURES, 2023, 54 : 1101 - 1113
  • [9] Effect of additional constraints of push-out test on the mechanical properties of perfobond shear connectors
    Zou, Yang
    Peng, Hongbo
    Zhang, Zhongya
    Jiang, Jinlong
    Guo, Jincen
    STRUCTURES, 2023, 47 : 991 - 1004
  • [10] Channel shear connectors in composite beams: Push-out tests
    Hosain, M. U.
    Pashan, Amit
    COMPOSITE CONSTRUCTION IN STEEL AND CONCRETE V, 2006, : 501 - +