Push-out tests and evaluation of FRP perfobond rib shear connectors performance

被引:3
|
作者
Kolpasky, Ludvik [1 ]
Ryjacek, Pavel [1 ]
机构
[1] Czech Tech Univ, Thakurova 7, Prague 16629 6, Czech Republic
关键词
CONCRETE;
D O I
10.1088/1757-899X/236/1/012069
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The behavioural characteristics of FRP (fibre-reinforced polymer) perfobond rib shear connector was examined through push-out tests in order to verify the applicability for pedestrian bridge structure. The aim of this study is to determine interaction between high performance concrete slab and handmade FRP plate which represent web of the composite beam. Combination of these modern materials leads to structural system with both great load bearing capacity and also sufficient flexural stiffness of the composite element. Openings cut into the GFRP plate at a variable spacing allow GFRP reinforcement bars to be inserted to act as shear studs. Hand lay-up process can increase suitable properties of FRP for connection by perfobond rib shear connectors. In this study, three push-out tests on fiber-reinforced polymer were performed to investigate their shear behaviour. The results of the push-out tests on FRP perfobond rib shear connector indicates great promise for application in full scale structures.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Push-Out Tests for Shear Connectors in GFRP-Concrete Composite Bridge Deck Slabs
    Huang, Hailin
    Li, Ao
    Chen, Lin
    Zeng, Chuijun
    Zhu, Mingqiao
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2018, 16 (08) : 368 - 381
  • [42] Push-out test of large perfobond connectors in steel-concrete joints of hybrid bridges
    Di, Jin
    Zou, Yang
    Zhou, Xuhong
    Qin, Fengjiang
    Peng, Xi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 150 : 415 - 429
  • [43] PUSH-OUT TESTS
    BLACK, J
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (11): : 1243 - 1245
  • [44] Applications of Hybrid System with Perfobond Rib Shear Connectors
    Kim, S. -H.
    Jung, C. -Y.
    Joung, J. -Y.
    Ahn, J. -H.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 2525 - 2533
  • [45] Push-out tests on stud shear connectors with constrained structure of steel-concrete composite beams
    Qia, Jingjing
    Xie, Zuwei
    Cao, Hua
    Huang, Zhi
    Lv, Weirong
    Shi, Weihua
    STRUCTURAL ENGINEERING AND MECHANICS, 2022, 83 (06) : 789 - 798
  • [46] Push-out tests of demountable headed stud shear connectors in steel-UHPC composite structures
    Wang, Jun-Yan
    Guo, Jun-Yuan
    Jia, Liang-Jiu
    Chen, Shi-Ming
    Dong, Yang
    COMPOSITE STRUCTURES, 2017, 170 : 69 - 79
  • [47] Push-out tests of shear connectors in U-shaped steel-concrete composite girder
    Liu, Yong
    Guo, Lanhui
    Shi, Jun
    Wang, Jingfeng
    STRUCTURES, 2021, 31 : 769 - 780
  • [48] HIGH TEMPERATURE PUSH-OUT TESTS ON DEMOUNTABLE SHEAR CONNECTORS OF STEEL-CONCRETE COMPOSITE BEAMS
    Mansilla, Roberto
    Espinós, Ana
    Payá-Faforteza, Ignacio
    Odenbreit, Christoph
    Romero, Manuel L.
    ce/papers, 2023, 6 (3-4) : 2074 - 2079
  • [49] Behavior of CFSC-Encased Shear Connectors in Steel-Concrete Joints: Push-Out Tests
    He, Shaohua
    Fang, Zhi
    Mosallam, Ayman S.
    Ouyang, Yi
    Zou, Chao
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (04)
  • [50] Push-out tests of shear connectors for new fully assembled steel-concrete composite beams
    Hou H.-T.
    Zang Z.-Y.
    Lu Y.-X.
    Liu J.-W.
    Ji K.-F.
    Wang Y.-M.
    Gongcheng Lixue/Engineering Mechanics, 2020, 37 (02): : 201 - 210