Push-out tests and evaluation of FRP perfobond rib shear connectors performance

被引:3
|
作者
Kolpasky, Ludvik [1 ]
Ryjacek, Pavel [1 ]
机构
[1] Czech Tech Univ, Thakurova 7, Prague 16629 6, Czech Republic
关键词
CONCRETE;
D O I
10.1088/1757-899X/236/1/012069
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The behavioural characteristics of FRP (fibre-reinforced polymer) perfobond rib shear connector was examined through push-out tests in order to verify the applicability for pedestrian bridge structure. The aim of this study is to determine interaction between high performance concrete slab and handmade FRP plate which represent web of the composite beam. Combination of these modern materials leads to structural system with both great load bearing capacity and also sufficient flexural stiffness of the composite element. Openings cut into the GFRP plate at a variable spacing allow GFRP reinforcement bars to be inserted to act as shear studs. Hand lay-up process can increase suitable properties of FRP for connection by perfobond rib shear connectors. In this study, three push-out tests on fiber-reinforced polymer were performed to investigate their shear behaviour. The results of the push-out tests on FRP perfobond rib shear connector indicates great promise for application in full scale structures.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] SMALL-SCALE PUSH-OUT TESTS ON WELDED STUD SHEAR CONNECTORS
    DAVIES, C
    CONCRETE, 1967, 1 (09): : 311 - &
  • [22] Numerical studies on shear connectors in push-out tests under elevated temperatures
    Wang, Aaron J.
    STRUCTURAL ENGINEERING AND MECHANICS, 2011, 39 (03) : 317 - 338
  • [23] Push-out tests for shear connections between UHPFRC slabs and FRP girder
    Nguyen, Hai
    Mutsuyoshi, Hiroshi
    Zatar, Wael
    COMPOSITE STRUCTURES, 2014, 118 : 528 - 547
  • [24] Push-Out Test on Shear Connectors Embedded in UHPC
    Kim, Jee Sang
    Park, Sang Hyeok
    Joh, Changbin
    Kwark, Jong D. K.
    Choi, Eun Suk
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 50 - 54
  • [25] Push-out behavior of GFRP bolts shear connectors in FRP-concrete hybrid beam
    Xue, Weichen
    Yan, Dawei
    Zhang, Shiqian
    ENGINEERING STRUCTURES, 2023, 294
  • [26] Push-out tests on demountable shear connectors of steel-concrete composite structures
    Kozma, A.
    Odenbreit, C.
    Braun, M., V
    Veljkovic, M.
    Nijgh, M. P.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 549 - 556
  • [27] Experimental investigation on the cyclic performance of perfobond rib shear connectors
    Li, Zhixiang
    Wu, Bin
    Liao, Man
    Yang, Xingwang
    Deng, Kailai
    Zhao, Canhui
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (16) : 3509 - 3524
  • [28] Push-out tests of straight shear connectors based on steel-concrete adherence
    Diogenes, H. J. F.
    El Debs, A. L. H. C.
    El Debs, M. K.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 2960 - 2966
  • [29] Bolted shear connectors vs. headed studs behaviour in push-out tests
    Pavlovic, Marko
    Markovic, Zlatko
    Veljkovic, Milan
    Budevac, Dragan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 88 : 134 - 149
  • [30] Finite element modelling of push-out tests for novel locking nut shear connectors
    Tzouka, E.
    Karavasilis, T.
    Kashani, M. M.
    Afshan, S.
    STRUCTURES, 2021, 33 : 1020 - 1032