Push-out tests on demountable shear connectors of steel-concrete composite structures

被引:4
|
作者
Kozma, A. [1 ]
Odenbreit, C. [1 ]
Braun, M., V [1 ]
Veljkovic, M. [2 ]
Nijgh, M. P. [2 ]
机构
[1] Univ Luxembourg, Res Unit Engn Sci, Luxembourg, Luxembourg
[2] Delft Univ Technol, Fac Civil Engn & Geosci, Delft, Netherlands
关键词
Demountable shear connectors; push-out tests; metal decking; circular economy; shear capacity; experimental study;
D O I
10.4995/ASCCS2018.2018.7155
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The deconstruction of steel-concrete composite structures in buildings and the later separation of the materials is a labour-and cost intensive work. The shear studs are welded on the steel beam and imbedded in the concrete deck and a large amount of cutting work becomes necessary. As a result, recycling is difficult and the potential for reusing entire elements is lost. The carbon footprint of composite structures could be decreased by application of the principles of "design for deconstruction and reuse". This paper presents a desk top study and corresponding laboratory experiments on demountable shear connectors that facilitate recyclability and even provide the potential for reusing complete structural elements. In the Laboratory of Steel and Composite Structures of the University of Luxembourg 15 push-out tests have been carried out using different bolted connection systems suitable for multiple uses in order to verify their performance focusing on shear strength, stiffness, slip capacity, ductility and ability of demounting. The investigated systems included pre-stressed and epoxy resin injection bolts, solid slabs and composite slabs with profiled decking. The results showed that the tested demountable shear connections could provide higher shear resistance than conventional shear connections. The critical failure mode is shear failure of the bolts, while there was no visible damage observed on the connected members. Most of the tested connections could fulfil the ductility requirement according to by Eurocode 4. The application of epoxy resin in the hole clearance resulted in lower slip capacity. The outcome provides an important basis for the justification of the forthcoming enhancement and validation of numerical models of the demountable shear connections. The failure behaviour, the observed damages and the resulting ability of the elements for re-use are discussed in detail.
引用
收藏
页码:549 / 556
页数:8
相关论文
共 50 条
  • [1] Push-out tests on demountable shear connectors of steel-concrete composite structures
    Kozma, A.
    Odenbreit, C.
    Braun, M., V
    Veljkovic, M.
    Nijgh, M. P.
    [J]. STRUCTURES, 2019, 21 : 45 - 54
  • [2] Push-out tests of demountable shear connectors for sustainable composite structures
    Kiraly, Krisztian
    Dunai, Laszlo
    Calado, Luis
    Balazs Kocsis, Andras
    [J]. STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2024,
  • [3] Characterization of the elevated temperature behaviour of demountable shear connectors in steel-concrete composite beams through push-out tests
    Mansilla, R.
    Espinos, A.
    Odenbreit, C.
    Paya-Zaforteza, I.
    Romero, M. L.
    [J]. STRUCTURES, 2024, 59
  • [4] Push-out tests of demountable headed stud shear connectors in steel-UHPC composite structures
    Wang, Jun-Yan
    Guo, Jun-Yuan
    Jia, Liang-Jiu
    Chen, Shi-Ming
    Dong, Yang
    [J]. COMPOSITE STRUCTURES, 2017, 170 : 69 - 79
  • [5] Push-out tests on stud shear connectors with constrained structure of steel-concrete composite beams
    Qia, Jingjing
    Xie, Zuwei
    Cao, Hua
    Huang, Zhi
    Lv, Weirong
    Shi, Weihua
    [J]. STRUCTURAL ENGINEERING AND MECHANICS, 2022, 83 (06) : 789 - 798
  • [6] Push-out tests of shear connectors in U-shaped steel-concrete composite girder
    Liu, Yong
    Guo, Lanhui
    Shi, Jun
    Wang, Jingfeng
    [J]. STRUCTURES, 2021, 31 : 769 - 780
  • [7] Push-out tests of shear connectors for new fully assembled steel-concrete composite beams
    Hou, He-Tao
    Zang, Zeng-Yun
    Lu, Yu-Xi
    Liu, Jin-Wei
    Ji, Ke-Fan
    Wang, Yan-Ming
    [J]. Gongcheng Lixue/Engineering Mechanics, 2020, 37 (02): : 201 - 210
  • [8] Push-out tests of straight shear connectors based on steel-concrete adherence
    Diogenes, H. J. F.
    El Debs, A. L. H. C.
    El Debs, M. K.
    [J]. BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 2960 - 2966
  • [9] Pushout tests on demountable bolted angle shear connectors for steel-concrete composite structures
    Karakus, Berk
    Arikoglu, Pinar
    Topkaya, Cem
    [J]. ENGINEERING STRUCTURES, 2024, 317
  • [10] Demountable shear connectors – constructional details and push-out tests
    Király, Krisztián
    Dunai, László
    Calado, Luis
    Kocsis, András Balázs
    [J]. ce/papers, 2023, 6 (3-4) : 53 - 58