Quencher-free molecular beacon: Enhancement of the signal-to-background ratio with graphene oxide

被引:25
|
作者
Yi, Jeong Wu [2 ]
Park, Jaesung [1 ]
Singh, N. Jiten [1 ]
Lee, Il Joon [2 ]
Kim, Kwang S. [1 ]
Kim, Byeang Hyean [2 ]
机构
[1] Pohang Univ Sci & Technol, BK Sch Mol Sci, Dept Chem, Ctr Superfunct Mat, Pohang, South Korea
[2] Pohang Univ Sci & Technol, BK Sch Mol Sci, Dept Chem, Lab Modified Nucle Acid Syst, Pohang 790784, South Korea
关键词
Quencher-free molecular beacon; Molecular beacon; Graphene oxide; Signal-to-background ratio; Fluorescence; NUCLEIC-ACIDS; DNA; FILMS; FLUORESCENCE; PLATFORM; SHEETS; STEM;
D O I
10.1016/j.bmcl.2010.12.004
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
We report the highly improved version of quencher-free molecular beacon (QF-MB) system by using graphene oxide (GO) as an external quencher. This QF-MB/GO system provided a higher S/B ratio (31,0) relative to that (2,2) of the same system in the absence of GO, while retaining a high selectivity for fully matched over single-base-mismatched targets. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:704 / 706
页数:3
相关论文
共 50 条
  • [41] Molecular beacon anchored onto a graphene oxide substrate
    Darbandi, Arash
    Datta, Debopam
    Patel, Krunal
    Lin, Gary
    Stroscio, Michael A.
    Dutta, Mitra
    NANOTECHNOLOGY, 2017, 28 (37)
  • [42] Quencher-free fluorescence strategy for detection of DNA methyltransferase activity based on exonuclease III-assisted signal amplification
    Liu, Haisheng
    Ma, Changbei
    Zhou, Meijuan
    Chen, Hanchun
    He, Hailun
    Wang, Kemin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (28) : 8111 - 8116
  • [43] MEASUREMENT OF THE SIGNAL-TO-BACKGROUND NOISE RATIO OF A SATELLITE TV CHANNEL WHEN THE ENERGY OF THE FM SIGNAL IS DISPERSED.
    Lokshin, B.A.
    Listov, I.B.
    Nikulin, N.I.
    Telecommunications and Radio Engineering (English translation of Elektrosvyaz and Radiotekhnika), 1983, 37-38 (05): : 12 - 14
  • [44] Quencher-free fluorescence strategy for detection of DNA methyltransferase activity based on exonuclease III-assisted signal amplification
    Haisheng Liu
    Changbei Ma
    Meijuan Zhou
    Hanchun Chen
    Hailun He
    Kemin Wang
    Analytical and Bioanalytical Chemistry, 2016, 408 : 8111 - 8116
  • [45] Simultaneously enhancing the resolution and signal-to-background ratio in STED optical nanoscopy via differential depletion
    Jeong, Sejoo
    Kim, Jaeyong
    Koh, Dongbin
    Lee, Jong-Chan
    OPTICS EXPRESS, 2023, 31 (23) : 37549 - 37563
  • [46] Surface-Enhanced Raman Scattering Bioimaging with an Ultrahigh Signal-to-Background Ratio under Ambient Light
    Zhu, Shuo
    Deng, Binge
    Liu, Fugang
    Li, Jin
    Lin, Li
    Ye, Jian
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (07) : 8876 - 8887
  • [47] Physical model of the signal-to-background ratio based PET-guided tumor volume delineation algorithm
    Balkay, L.
    Lajtos, I.
    Garai, I.
    Emri, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S261 - S261
  • [48] An optical fiber microprobe for surface-enhanced Raman scattering sensing with enhanced signal-to-background ratio
    Al Mamun, Md Abdullah
    Katkus, Tomas
    Juodkazis, Saulius
    Stoddart, Paul R.
    SPIE MICRO + NANO MATERIALS, DEVICES, AND APPLICATIONS 2019, 2019, 11201
  • [49] Rational Design of a Rigid Fluorophore Molecular Rotor-Based Probe for High Signal-to-Background Ratio Detection of Sulfur Dioxide in Viscous System
    He, Longwei
    Yang, Yunzhen
    Lin, Weiying
    ANALYTICAL CHEMISTRY, 2019, 91 (23) : 15220 - 15228
  • [50] Dose escalation study on FET-PET delineated glioblastoma based on a signal-to-background ratio adaptive thresholding
    Garibotto, V.
    Buchegger, F.
    Caparrotti, F.
    Wissmeyer, M.
    Zaidi, H.
    Miralbell, R.
    Ratib, O.
    Weber, D. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S340 - S341