Accuracy of a 3D fluoroscopic navigation system using a flat-panel detector-equipped C-arm

被引:12
|
作者
Takao, Masaki [1 ]
Yabuta, Kentaro [1 ]
Nishii, Takashi
Sakai, Takashi [1 ]
Sugano, Nobuhiko
机构
[1] Osaka Univ, Grad Sch Med, Dept Orthopaed Sugery, Suita, Osaka 5650871, Japan
基金
日本学术振兴会;
关键词
3D fluoroscopic navigation; flat-panel detector; accuracy; image distortion; SCREW PLACEMENT; CLINICAL ACCURACY; SURGERY; EXCISION; ISO-C-3D;
D O I
10.3109/10929088.2011.602117
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The aim of this study was to evaluate the accuracy of a novel 3-dimensional (3D) fluoroscopic navigation system using a flat-panel detector-equipped C-arm, focusing on the influence of the distance from the center of fluoroscopic imaging on navigation accuracy. Materials and Methods: A geometric phantom was made using a Styrofoam cube with 25 markers, each consisting of a metal ball 1.5 mm in diameter, fixed in a cross arrangement at 1-cm intervals. Hip joint surgery was simulated using a set of dry pelvic and femoral bones. A total of eight markers were fixed to the acetabulum and proximal femur. Results: In the geometric phantom study, mean target registration error (TRE) was 0.7 mm (range: 0.1-1.5). The TRE of markers located at 5 cm from the imaging center was significantly higher than the TRE of markers located at 1 and 2 cm. However, the TRE was <1 mm in 90% of the overall trials and <1.5 mm in 100%. In the dry bone study, the mean TRE was 0.9 mm (range: 0.7-1.5) over the acetabulum and 1.0 mm (range: 0.5-1.4) over the femur. No significant difference in TRE was seen between the acetabulum and proximal femur. Conclusion: The accuracy of this novel 3D fluoroscopic navigation system was considered acceptable for clinical application. A 3D C-arm equipped with a flat-panel detector could increase the feasibility of 3D fluoroscopic navigation by reducing the effects of image distortion on navigation accuracy.
引用
收藏
页码:234 / 239
页数:6
相关论文
共 50 条
  • [41] Neuroradiologic Applications with Routine C-arm Flat Panel Detector CT: Evaluation of Patient Dose Measurements
    Kyriakou, Y.
    Richter, G.
    Doerfler, A.
    Kalender, W. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (10) : 1930 - 1936
  • [42] Intraoperative C-arm fluoroscopy-based 3D navigation for intraventricular endoscopic intervention
    Herbowski, L.
    Sagan, L.
    Szylak, R.
    Salapa, P.
    Harat, A.
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2013, 27 (04) : 537 - 539
  • [43] Flat-panel backlight for view-sequential 3D display
    Lee, CMG
    Travis, ARL
    [J]. IEE PROCEEDINGS-OPTOELECTRONICS, 2004, 151 (06): : 486 - 489
  • [44] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208
  • [45] Comparison of 3D C-arm fluoroscopy and 3D image-guided navigation for minimally invasive pelvic surgery
    Li, Bin
    He, Jiliang
    Zhu, Zexing
    Zhou, Dongsheng
    Hao, Zhenhai
    Wang, Yonghui
    Li, Qinghu
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (10) : 1527 - 1534
  • [46] Change your Angle of View Sinusoidal C-Arm Movement in Cranial Flat-panel CT to Improve Image Quality
    Luecking, Hannes
    Hoelter, Philip
    Lang, Stefan
    Schmidt, Manuel
    Eisenhut, Felix
    Doerfler, Arnd
    [J]. CLINICAL NEURORADIOLOGY, 2022, 32 (04) : 1109 - 1115
  • [47] Modelling the acquisition geometry of a C-arm angiography system for 3D reconstruction
    Cañero, C
    Nofrerías, E
    Mauri, J
    Radeva, P
    [J]. TOPICS IN ARTIFICIAL INTELLIGENCE, PROCEEDINGS, 2002, 2504 : 322 - 335
  • [48] Comparison of 3D C-arm fluoroscopy and 3D image-guided navigation for minimally invasive pelvic surgery
    Bin Li
    Jiliang He
    Zexing Zhu
    Dongsheng Zhou
    Zhenhai Hao
    Yonghui Wang
    Qinghu Li
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1527 - 1534
  • [49] Detection of Pulmonary Embolism Using a Novel Dynamic Flat-Panel Detector System in Monkeys
    Miyatake, Hidemitsu
    Tabata, Takahisa
    Tsujita, Yasuyuki
    Fujino, Kazunori
    Tanaka, Rie
    Eguchi, Yutaka
    [J]. CIRCULATION JOURNAL, 2021, 85 (04) : 361 - 368
  • [50] Accuracy of navigation on 3DRX data acquired with a mobile propeller C-arm
    van Walsum, T
    van de Kraats, EB
    Carelsen, B
    Boon, SN
    Noordhoek, N
    Niessen, WJ
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 2, PROCEEDINGS, 2004, 3217 : 455 - 461