Modelling the acquisition geometry of a C-arm angiography system for 3D reconstruction

被引:0
|
作者
Cañero, C
Nofrerías, E
Mauri, J
Radeva, P
机构
[1] UAB, Comp Vis Ctr, Cerdanyola Del Valles 08190, Spain
[2] Univ Autonoma Barcelona, Dept Comp Sci, E-08193 Barcelona, Spain
[3] Hosp Univ Germans Tries & Pujol, Badalona, Spain
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper is concerned with the calibration of the intrinsic and extrinsic parameters of a X-ray angiographic system for 3D reconstruction of coronary vessel centerlines. We discuss whether the isocentric model is an accurate model for the movement of the C-arm, and analyse the assumptions made by this model. We propose a methodology which takes into account these facts and we propose for each model a calibration method. The calibration only needs a phantom that is commonly available by the physicians, since it is used to calibrate geometrical distortion. Then, we test the models with the calibration grid, as well as with a phantom imaged three months later. Experimental results show that by using the proposed models, it is not necessary neither a calibration nor a refinement at each acquisition.
引用
收藏
页码:322 / 335
页数:14
相关论文
共 50 条
  • [1] Mobile C-arm 3D Reconstruction in the Presence of Uncertain Geometry
    Rottman, Caleb
    McBride, Lance
    Cheryauka, Arvidas
    Whitaker, Ross
    Joshi, Sarang
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II, 2015, 9350 : 692 - 699
  • [2] 3D reconstruction from projection matrices in a C-arm based 3D-angiography system
    Navab, N
    Bani-Hashemi, A
    Nadar, MS
    Wiesent, K
    Durlak, P
    Brunner, T
    Barth, K
    Graumann, R
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 119 - 129
  • [3] Parallelizable 3D statistical reconstruction for C-arm tomosynthesis system
    Wang, BL
    Barner, K
    Lee, D
    MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 2171 - 2182
  • [4] C-arm angiography (DYNA-CT) for 3D Coronary Reconstruction and Myocardial Perfusion Assessment
    Rittger, Harald
    Lauritsch, Guenter
    Brachmann, Johannes
    Rieber, Johannes
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B93 - B93
  • [5] Intraoperative soft tissue 3D reconstruction with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 200 - 206
  • [6] Mask free Intravenous 3D Digital Subtraction Angiography (IV 3D-DSA) from a single C-arm acquisition
    Li, Yinsheng
    Niu, Kai
    Yang, Pengfei
    Aagaard-Kienitz, Beveley
    Niemann, David B.
    Ahmed, Azam S.
    Strother, Charles
    Chen, Guang-Hong
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [7] 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT
    Montoya, J. C.
    Li, Y.
    Strother, C.
    Chen, G. -H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (05) : 916 - 922
  • [8] A cheap and easy method for 3D C-arm reconstruction using elliptic curves
    Burkhardt, David
    Jain, Ameet
    Fichtinger, Gabor
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [9] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208
  • [10] Camera-augmented mobile C-arm (CAMC) application:: 3D reconstruction using a low-cost mobile C-arm
    Navab, N
    Mitschke, M
    Schütz, O
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 688 - 697