Inter-observer agreement of vertebral fracture assessment with dual-energy x-ray absorptiometry equipment

被引:2
|
作者
Mostert, Jacob M. [1 ]
Romeijn, Stephan R. [1 ]
Dibbets-Schneider, Petra [1 ]
Rietbergen, Daphne D. D. [1 ]
Pereira Arias-Bouda, Lenka M. [1 ,2 ]
Goetz, Christoph [3 ]
DiFranco, Matthew D. [3 ]
Dimai, Hans Peter [4 ]
Grootjans, Willem [1 ]
机构
[1] Leiden Univ, Dept Radiol, Med Ctr, Leiden, Netherlands
[2] Alrijne Hosp, Dept Radiol, Leiderdorp, Netherlands
[3] Image Biopsy Lab, Vienna, Austria
[4] Med Univ Graz, Dept Internal Med, Div Endocrinol & Diabetol, Graz, Austria
关键词
Vertebral fracture assessment; Dual-energy x-ray absorptiometry; Vertebral morphometry; Inter-observer agreement; Osteoporosis; ASSESSMENT VFA; PREVALENT; OSTEOPOROSIS; DEFORMITIES; DIAGNOSIS; WOMEN; RISK; DXA;
D O I
10.1007/s11657-021-01046-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To investigate the time and effort needed to perform vertebral morphometry, as well as inter-observer agreement for identification of vertebral fractures on vertebral fracture assessment (VFA) images. Methods Ninety-six images were retrospectively selected, and three radiographers independently performed semi-automatic 6-point morphometry. Fractures were identified and graded using the Genant classification. Time needed to annotate each image was recorded, and reader fatigue was assessed using a modified Simulator Sickness Questionnaire (SSQ). Inter-observer agreement was assessed per-patient and per-vertebra for detecting fractures of all grades (grades 1-3) and for grade 2 and 3 fractures using the kappa statistic. Variability in measured vertebral height was evaluated using the intraclass correlation coefficient (ICC). Results Per-patient agreement was 0.59 for grades 1-3 fracture detection, and 0.65 for grades 2-3 only. Agreement for per-vertebra fracture classification was 0.92. Vertebral height measurements had an ICC of 0.96. Time needed to annotate VFA images ranged between 91 and 540 s, with a mean annotation time of 259 s. Mean SSQ scores were significantly lower at the start of a reading session (1.29; 95% CI: 0.81-1.77) compared to the end of a session (3.25; 95% CI: 2.60-3.90; p < 0.001). Conclusion Agreement for detection of patients with vertebral fractures was only moderate, and vertebral morphometry requires substantial time investment. This indicates that there is a potential benefit for automating VFA, both in improving inter-observer agreement and in decreasing reading time and burden on readers.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] LIMITATIONS OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    TOTHILL, P
    NORD, RH
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (02): : 398 - 399
  • [32] Dual-energy x-ray absorptiometry in osteopetrosis
    Adler, IN
    Stine, KC
    Kurtzburg, J
    Kinder, DL
    Cox, KS
    Lensing, SY
    Seibert, JJ
    SOUTHERN MEDICAL JOURNAL, 2000, 93 (05) : 501 - 503
  • [33] Influence of vertebral fracture assessment by dual-energy X-ray absorptiometry on decision-making in osteoporosis: a structured vignette survey
    Roux, Christian
    Baron, Gabriel
    Audran, Maurice
    Breuil, Veronique
    Chapurlat, Roland
    Cortet, Bernard
    Fardellone, Patrice
    Tremollieres, Florence
    Ravaud, Philippe
    RHEUMATOLOGY, 2011, 50 (12) : 2264 - 2269
  • [34] Interpretation of calcaneus dual-energy X-ray absorptiometry measurements in the assessment of osteopenia and fracture risk
    Wren, TAL
    Yerby, SA
    Beaupré, GS
    Carter, DR
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (08) : 1573 - 1578
  • [35] Comparison of plain vertebral X-ray and dual-energy X-ray absorptiometry for the identification of older women for fracture prevention in primary care
    Robinson, P. J.
    Bell, R. J.
    Lanzafame, A.
    Segal, L.
    Kirby, C.
    Piterman, L.
    Davis, S. R.
    INTERNAL MEDICINE JOURNAL, 2013, 43 (01) : 38 - 45
  • [36] Muscle Assessment by Ultrasonography: Agreement with Dual-Energy X-Ray Absorptiometry (DXA) and Relationship with Physical Performance
    Neira Alvarez, M.
    Vazquez Ronda, M. A.
    Soler Rangel, L.
    Thuissard-Vasallo, I. J.
    Andreu-Vazquez, C.
    Martinez Martin, P.
    Rabago Lorite, I
    San Martin, G. Serralta
    JOURNAL OF NUTRITION HEALTH & AGING, 2021, 25 (08): : 956 - 963
  • [37] Evaluation of vertebral fracture assessment by dual X-ray absorptiometry in a multicenter setting
    Fuerst, T.
    Wu, C.
    Genant, H. K.
    von Ingersleben, G.
    Chen, Y.
    Johnston, C.
    Econs, M. J.
    Binkley, N.
    Vokes, T. J.
    Crans, G.
    Mitlak, B. H.
    OSTEOPOROSIS INTERNATIONAL, 2009, 20 (07) : 1199 - 1205
  • [38] Muscle Assessment by Ultrasonography: Agreement with Dual-Energy X-Ray Absorptiometry (DXA) and Relationship with Physical Performance
    M. Neira Álvarez
    Miguel A. Vázquez Ronda
    L. Soler Rangel
    I. J. Thuissard-Vasallo
    C. Andreu-Vazquez
    P. Martinez Martin
    I. Rábago Lorite
    G. Serralta San Martín
    The journal of nutrition, health & aging, 2021, 25 : 956 - 963
  • [39] Evaluation of vertebral fracture assessment by dual X-ray absorptiometry in a multicenter setting
    T. Fuerst
    C. Wu
    H. K. Genant
    G. von Ingersleben
    Y. Chen
    C. Johnston
    M. J. Econs
    N. Binkley
    T. J. Vokes
    G. Crans
    B. H. Mitlak
    Osteoporosis International, 2009, 20 : 1199 - 1205
  • [40] Body composition assessment by dual-energy X-ray absorptiometry (DXA)
    Andreoli, A.
    Scalzo, G.
    Masala, S.
    Tarantino, U.
    Guglielmi, G.
    RADIOLOGIA MEDICA, 2009, 114 (02): : 286 - 300