Interpretation of calcaneus dual-energy X-ray absorptiometry measurements in the assessment of osteopenia and fracture risk

被引:8
|
作者
Wren, TAL
Yerby, SA
Beaupré, GS
Carter, DR
机构
[1] Vet Affairs Hlth Care Syst, Rehabil Res & Dev Ctr 153, Palo Alto, CA 94304 USA
[2] Stanford Univ, Dept Mech Engn, Biomech Engn Div, Stanford, CA 94305 USA
关键词
osteopenia; fracture risk; bone mineral density; bone mineral apparent density; apparent density;
D O I
10.1359/jbmr.2000.15.8.1573
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-energy X-ray absorptiometry (DXA) of the calcaneus is useful in assessing bone mass and fracture risk at other skeletal sites. However, DXA yields an areal bone mineral density (BMD) that depends con both bone apparent density and bone size, potentially complicating interpretation of the DXA results. Information that is more complete may be obtained from DXA exams by using a volumetric density in addition to BMD in clinical applications. In this paper, we develop a simple methodology for determining a volumetric bone mineral apparent density (BMAD) of the calcaneus. For the whole calcaneus, BMAD = (BMC)/A(DXA)(3/2), where BMC and A(DXA), are, respectively, the bone mineral content and projected area measured by DXA. We found that A(DXA)(3/2) was proportional to the calcaneus volume with a proportionality constant of 1.82 +/- 0.02 (mean +/- SE). Consequently, consistent with theoretical predictions, BMAD was proportional to the true volumetric apparent density (rho) of the bone according to the relationship rho = 1.82 BMAD. Also consistent with theoretical predictions, we found that BMD varied in proportion to rho V-1/3, where Vis the bone volume. We propose that the volumetric apparent density, estimated at the calcaneus, provides additional information that may aid in the diagnosis of osteopenia. Areal BMD or BMD2 may allow estimation of the load required to fracture a bone. Fracture risk depends on the loading applied to a bone in relation to the bone's failure load. When DXA is used to assess osteopenia and fracture risk in patients, it may be useful to recognize the separate and combined effects of applied loading, bone apparent density, and bone size.
引用
收藏
页码:1573 / 1578
页数:6
相关论文
共 50 条
  • [1] Calcaneus ultrasonometry and dual-energy X-ray absorptiometry for the evaluation of vertebral fracture risk
    Frediani, B.
    Acciai, C.
    Falsetti, P.
    Baldi, F.
    Filippou, G.
    Siagkri, C.
    Spreafico, A.
    Galeazzi, M.
    Marcolongo, R.
    CALCIFIED TISSUE INTERNATIONAL, 2006, 79 (04) : 223 - 229
  • [2] Calcaneus Ultrasonometry and Dual-Energy X-Ray Absorptiometry for the Evaluation of Vertebral Fracture Risk
    B. Frediani
    C. Acciai
    P. Falsetti
    F. Baldi
    G. Filippou
    C. Siagkri
    A. Spreafico
    M. Galeazzi
    R. Marcolongo
    Calcified Tissue International, 2006, 79 : 223 - 229
  • [3] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [4] Vertebral fracture assessment by new dual-energy X-ray absorptiometry
    Bazzocchi, Alberto
    Spinnato, Paolo
    Fuzzi, Federica
    Diano, Danila
    Morselli-Labate, Antonio M.
    Sassi, Claudia
    Salizzoni, Eugenio
    Battista, Giuseppe
    Guglielmi, Giuseppe
    BONE, 2012, 50 (04) : 836 - 841
  • [5] Comparison of calcaneus ultrasound and dual X-ray absorptiometry in children at risk of osteopenia
    Fielding, KT
    Nix, DA
    Bachrach, LK
    JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (01) : 7 - 15
  • [6] RELIABILITY OF VERTEBRAL FRACTURE ASSESSMENT ON DUAL-ENERGY X-RAY ABSORPTIOMETRY
    Yasmine, M.
    Mariem, S.
    Miladi, S.
    Fazaa, A.
    Fguiri, E.
    Souebni, L.
    Ouenniche, K.
    Kassab, S.
    Chekili, S.
    Ben Abdelghani, K.
    Laatar, A.
    ANNALS OF THE RHEUMATIC DISEASES, 2021, 80 : 835 - 835
  • [7] Bone mineral density assessment -: Comparison of dual-energy X-ray absorptiometry measurements at the calcaneus, spine, and hip
    Sweeney, AT
    Malabanan, AO
    Blake, MA
    Weinberg, J
    Turner, A
    Ray, P
    Holick, ME
    JOURNAL OF CLINICAL DENSITOMETRY, 2002, 5 (01) : 57 - 62
  • [8] Comparison of ultrasound and dual energy X-ray absorptiometry measurements in the calcaneus
    Kang, C
    Speller, R
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (848): : 861 - 867
  • [9] MEASUREMENT OF THE CALCANEUS BY ULTRASOUND AND DUAL-ENERGY X-RAY ABSORPTIOMETRY IN POSTMENOPAUSAL OSTEOPOROSIS
    NAYLOR, KE
    LANGTON, CM
    SMITH, TWD
    EASTELL, R
    JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 : S353 - S353
  • [10] Quantitative ultrasound of the radius and calcaneus: a comparison with dual-energy X-ray absorptiometry
    Boyanov, M.
    Shinkov, A.
    Nestorova, R.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2007, 132 (16) : 869 - 873