Inter-observer agreement of vertebral fracture assessment with dual-energy x-ray absorptiometry equipment

被引:2
|
作者
Mostert, Jacob M. [1 ]
Romeijn, Stephan R. [1 ]
Dibbets-Schneider, Petra [1 ]
Rietbergen, Daphne D. D. [1 ]
Pereira Arias-Bouda, Lenka M. [1 ,2 ]
Goetz, Christoph [3 ]
DiFranco, Matthew D. [3 ]
Dimai, Hans Peter [4 ]
Grootjans, Willem [1 ]
机构
[1] Leiden Univ, Dept Radiol, Med Ctr, Leiden, Netherlands
[2] Alrijne Hosp, Dept Radiol, Leiderdorp, Netherlands
[3] Image Biopsy Lab, Vienna, Austria
[4] Med Univ Graz, Dept Internal Med, Div Endocrinol & Diabetol, Graz, Austria
关键词
Vertebral fracture assessment; Dual-energy x-ray absorptiometry; Vertebral morphometry; Inter-observer agreement; Osteoporosis; ASSESSMENT VFA; PREVALENT; OSTEOPOROSIS; DEFORMITIES; DIAGNOSIS; WOMEN; RISK; DXA;
D O I
10.1007/s11657-021-01046-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To investigate the time and effort needed to perform vertebral morphometry, as well as inter-observer agreement for identification of vertebral fractures on vertebral fracture assessment (VFA) images. Methods Ninety-six images were retrospectively selected, and three radiographers independently performed semi-automatic 6-point morphometry. Fractures were identified and graded using the Genant classification. Time needed to annotate each image was recorded, and reader fatigue was assessed using a modified Simulator Sickness Questionnaire (SSQ). Inter-observer agreement was assessed per-patient and per-vertebra for detecting fractures of all grades (grades 1-3) and for grade 2 and 3 fractures using the kappa statistic. Variability in measured vertebral height was evaluated using the intraclass correlation coefficient (ICC). Results Per-patient agreement was 0.59 for grades 1-3 fracture detection, and 0.65 for grades 2-3 only. Agreement for per-vertebra fracture classification was 0.92. Vertebral height measurements had an ICC of 0.96. Time needed to annotate VFA images ranged between 91 and 540 s, with a mean annotation time of 259 s. Mean SSQ scores were significantly lower at the start of a reading session (1.29; 95% CI: 0.81-1.77) compared to the end of a session (3.25; 95% CI: 2.60-3.90; p < 0.001). Conclusion Agreement for detection of patients with vertebral fractures was only moderate, and vertebral morphometry requires substantial time investment. This indicates that there is a potential benefit for automating VFA, both in improving inter-observer agreement and in decreasing reading time and burden on readers.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Precision assessment and radiation safety for dual-energy X-ray absorptiometry
    Baim, S
    Wilson, CR
    Lewiecki, EM
    Luckey, MM
    Downs, RW
    Lentle, BC
    JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (04) : 371 - 378
  • [42] Bone age assessment by dual-energy X-ray absorptiometry in children: an alternative for X-ray?
    Heppe, D. H. M.
    Taal, H. R.
    Ernst, G. D. S.
    Van den Akker, E. L. T.
    Lequin, M. M. H.
    Hokken-Koelega, A. C. S.
    Geelhoed, J. J. M.
    Jaddoe, V. W. V.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1010): : 114 - 120
  • [43] Fracture stiffness in callotasis determined by dual-energy X-ray absorptiometry scanning
    Tselentakis, G
    Owen, PJ
    Richardson, JB
    Kuiper, JH
    Haddaway, MJ
    Dwyer, JSM
    Evans, GA
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2001, 10 (03): : 248 - 254
  • [44] Comparison of dual-energy X-ray absorptiometry and conventional radiography for the detection of vertebral fractures
    Pavloy, L
    Gamble, GD
    Reid, IR
    JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (04) : 379 - 385
  • [45] Performance of vertebral fracture assessment (vfa) using the ge idxa (dual-energy x-ray absorptiometry) scanner compared to conventional radiography
    Diacinti, D.
    Del Fiacco, R.
    Pisani, D.
    Diacinti, D., II
    Todde, F.
    Romagnoli, E.
    Pepe, J.
    Cipriani, C.
    Minisola, S.
    BONE, 2012, 50 : S147 - S147
  • [46] A comparison of visual and automated methods of vertebral exclusion in dual-energy X-ray absorptiometry
    Tsang, J.
    Leslie, W. D.
    OSTEOPOROSIS INTERNATIONAL, 2006, 17 : S166 - S166
  • [47] SIMULATION STUDIES OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    SORENSON, JA
    DUKE, PR
    SMITH, SW
    MEDICAL PHYSICS, 1989, 16 (01) : 75 - 80
  • [48] Dual-energy X-ray absorptiometry in early life
    Lapillonne, A
    Braillon, PM
    Delmas, PD
    Salle, BL
    HORMONE RESEARCH, 1997, 48 : 43 - 49
  • [49] Dual-energy X-ray absorptiometry scan: Guidelines
    Haymann, Jean-Philippe
    PROGRES EN UROLOGIE, 2010, 20 (04): : F119 - F122
  • [50] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN NEUROMUSCULAR DISEASES
    KANDA, F
    FUJII, Y
    TAKAHASHI, K
    FUJITA, T
    MUSCLE & NERVE, 1994, 17 (04) : 431 - 435