Partial volume correction of lung nodules using PET/CT

被引:0
|
作者
Bradley, W. [1 ]
Wendt, R. [1 ]
Pan, T. [1 ]
Erasmus, J. [1 ]
White, R. [1 ]
Mawlawi, O. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2761365
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Partial voluming in PET imaging leads to underestimation in activity concentration. The aim of this abstract is to correct for partial volume artifacts in PET/CT scans. Method and Materials: A Jaszczak phantom with hollow spheres of varying sizes (4.95 – 31.27 mm inner diameter (ID)) was filled with F‐18 water using 3 different sphere‐to‐background ratios (SBR), ranging from 3:1 to 10:1. For each SBR, several acquisitions were conducted. All PET data was reconstructed using OSEM (2 iterations, 21 subsets). Regions were drawn on the CT images to obtain accurate sphere volume and location. A software tool was written to correct for partial voluming by incorporating the sphere size and the non‐stationary response function of the scanner. The original maximum (OM), original average (OA), corrected maximum (CM), and corrected average (CA) activity concentrations (AC) were measured and compared. Results: For all SBRs, spheres larger than 19 mm the measured OM and OA AC were 111 and 77% of the true value, respectively. Following correction, these values changed to 128 (CM) and 102% (CA), respectively. For the smallest sphere size (4.95 mm), the measured OM and OA AC were both 20% of the true value. Following correction, these values changed to 121 (CM) and 104% (CA) of the true value. The CM, however, did vary between 83 and 176% of the true AC. An analytical relationship between the lesion size (obtained from CT) and the amount of correction needed to recover the true AC based on the multiple acquisitions was generated. Conclusions: To determine the true AC of a lesion from a PET/CT scan, the corrected average is more accurate than the original maximum, and should be used for clinical assessment. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2553 / 2553
页数:1
相关论文
共 50 条
  • [1] The Impact of Partial Volume Correction in the Evaluation of Solitary Pulmonary Nodules by FDG PET/CT in a Population at Intermediate Risk of Lung Cancer
    Keu, K.
    Nair, V. S.
    Mittra, E.
    Gambhir, S. S.
    Iagaru, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S455 - S455
  • [2] Combined motion blur and partial volume correction for computer aided diagnosis of pulmonary nodules in PET/CT
    Wiemker, Rafael
    Paulus, Timo
    Kabus, Sven
    Buelow, Thomas
    Apostolova, Ivayla
    Buchert, Ralph
    Klutmann, Susanne
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 3 (1-2) : 105 - 113
  • [3] Combined motion blur and partial volume correction for computer aided diagnosis of pulmonary nodules in PET/CT
    Rafael Wiemker
    Timo Paulus
    Sven Kabus
    Thomas Bülow
    Ivayla Apostolova
    Ralph Buchert
    Susanne Klutmann
    International Journal of Computer Assisted Radiology and Surgery, 2008, 3 : 105 - 113
  • [4] FDG PET imaging and partial volume correction in the assessment of pulmonary nodules
    Alkhawaldeh, K. M.
    Dadparvar, S.
    Bural, G.
    Houseni, M.
    El-Haddad, G.
    Alavi, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S108 - S108
  • [5] Joint correction of respiratory motion artifact and partial volume effect in lung PET/CT imaging
    Chang, Guoping
    Chang, Tingting
    Clark, John
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [6] Impact of partial volume correction on small malignant lung nodules.
    Kitapci, MT
    Turkington, TG
    Coleman, RE
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 257P - 257P
  • [7] Partial-Volume Effect and a Partial-Volume Correction for the NanoPET/CT™ Preclinical PET/CT Scanner
    Szanda, Istvan
    Livieratos, Lefteris
    Patay, Gergely
    Tsoumpas, Charalampos
    Sunassee, Kavitha
    Mullen, Gregory E.
    Nemeth, Gabor
    Major, Peter
    Marsden, Paul K.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3605 - 3609
  • [8] Post-reconstruction partial volume correction of PET using CT side information
    Moody, Jonathan
    Lee, Benjamin
    Ficaro, Edward
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [9] Joint correction of respiratory motion artifact and partial volume effect in lung/thoracic PET/CT imaging
    Chang, Guoping
    Chang, Tingting
    Pan, Tinsu
    Clark, John W., Jr.
    Mawlawi, Osama R.
    MEDICAL PHYSICS, 2010, 37 (12) : 6221 - 6232
  • [10] Accuracy and precision of partial volume correction in oncological PET/CT studies
    Cysouw, Matthijs
    Kramer, Gem
    Hoekstra, Otto
    Frings, Virginie
    de Langen, Joop
    Smit, E.
    Van den Eertwegh, Alfons
    Oprea-Lager, Daniela
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57