Evaluation of ADC testing systems using ADC transfer standard

被引:3
|
作者
Haasz, V [1 ]
Roztocil, J [1 ]
Slepicka, D [1 ]
机构
[1] Czech Tech Univ, Fac Elect Engn, Dept Measurement, CZ-16627 Prague, Czech Republic
关键词
analog-to-digital converter (ADC) testing; analog-to-digital (AD) transfer standard; comparative measurements; ENOB; frequency spectrum averaging; generator instability; SINAD; THD;
D O I
10.1109/TIM.2005.847119
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A transportable high-stability reference AD device was designed and built to compare the systems for testing the dynamic quality of analog-to-digital converters (ADCs) or analog-to-digital (AD) modules. Three different input modules can be used in the frequency range up to 5 MHz. First, this paper refers to the results of an AD device application in the frequency range of the testing signal up to 100 kHz, where four ADC testing systems were compared in different laboratories, and a short time amplitude and/or frequency instability of testing signal generators was evaluated. Second, it describes the first experience of its application in the frequency range from 100-5 MHz.
引用
收藏
页码:1150 / 1155
页数:6
相关论文
共 50 条
  • [21] Testing technique for embedded ADC
    Zagursky, V
    Gertners, A
    APCCAS '98 - IEEE ASIA-PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS: MICROELECTRONICS AND INTEGRATING SYSTEMS, 1998, : 775 - 778
  • [22] ADC & DAC modelling and testing
    Daponte, Pasquale
    Michaeli, Linus
    MEASUREMENT, 2007, 40 (05) : 459 - 462
  • [23] Universal ADC testing software
    Brossmann, J
    Varga, D
    Roztocil, J
    BEC 2002: Proceedings of the 8th Biennial Baltic Electronic Conference, 2002, : 229 - 230
  • [24] Testing technique for embedded ADC
    Technical Univ, Riga, Latvia
    IEEE Asia Pac Conf Circuits Syst Proc, (775-778):
  • [25] Preoperative Evaluation of Prostate Cancer Aggressiveness: Using ADC and ADC Ratio in Determining Gleason Score
    Woo, Sungmin
    Kim, Sang Youn
    Cho, Jeong Yeon
    Kim, Seung Hyup
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 114 - 120
  • [26] Introduction to the special issue on ADC testing, 6th EuroWorkshop on ADC Modelling and Testing
    Serra, AC
    COMPUTER STANDARDS & INTERFACES, 2003, 25 (01) : 1 - 2
  • [27] Estimation of Error in Nonlinearity in ADC using Standard Histogram Technique
    Gamad, R. S.
    Mishra, D. K.
    WCECS 2008: WORLD CONGRESS ON ENGINEERING AND COMPUTER SCIENCE, 2008, : 185 - 188
  • [28] Preliminary considerations on ADC standard harmonization
    Rapuano, Sergio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (02) : 386 - 394
  • [30] Measuring and evaluating dynamic ADC parameters - Dynamic ADC testing, Part 2
    Hofner, TC
    MICROWAVES & RF, 2000, 39 (13) : 78 - +