Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patients with acute myocardial infarction

被引:7
|
作者
Gasior, Pawel [1 ]
Gierlotka, Marek [2 ,3 ]
Szczurek-Katanski, Krzysztof [4 ]
Osuch, Marcin [4 ]
Roleder, Magda [1 ]
Hawranek, Michal [5 ,6 ]
Gasior, Mariusz [5 ,6 ]
Wojakowski, Wojciech [1 ]
Polonski, Lech [5 ,6 ]
机构
[1] Med Univ Silesia, Dept Cardiol & Struct Heart Dis, 45-47 Ziolowa St, PL-40635 Katowice, Poland
[2] Silesian Ctr Heart Dis, Dept Cardiol 3, Zabrze, Poland
[3] Univ Opole, Univ Hosp, Fac Nat Sci & Technol, Dept Cardiol, Opole, Poland
[4] Scanmed, Krakow, Poland
[5] Med Univ Silesia, Sch Med, Dept Cardiol 3, Div Dent Zabrze, Katowice, Poland
[6] Silesian Ctr Heart Dis, Zabrze, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2018年 / 14卷 / 04期
关键词
acute myocardial infarction; bioabsorbable polymer; drug-eluting stents; PERCUTANEOUS CORONARY INTERVENTION; BARE-METAL STENTS; RANDOMIZED CONTROLLED-TRIALS; DUAL ANTIPLATELET THERAPY; NETWORK METAANALYSIS; ARTERY-DISEASE; CLINICAL-OUTCOMES; POOLED ANALYSIS; THROMBOSIS; EVENTS;
D O I
10.5114/aic.2018.79194
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The biodegradable polymer drug-eluting stents were developed to improve vascular healing. However, further data are needed to confirm the safety and efficacy of these stents in patients with acute myocardial infarction (AMI). Aim: We sought to determine the 1-year clinical follow-up in patients with AMI treated with a thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus a durable coating everolimus-eluting stent (DP-EES). Material and methods: We analyzed patients with AMI (STEMI and NSTEMI) treated with either a BP-SES (ALEX, Balton, Poland, n = 886) or DP-EES (XIENCE, Abbott, USA, n = 1054) with available 1-year clinical follow-up using propensity score matching. Outcomes included target vessel revascularization (TVR) as the efficacy outcome and all-cause death, myocardial infarction, and definite/probable stent thrombosis as safety outcomes. Results: After propensity score matching 672 patients treated with BP-SES and 672 patients treated with DP-EES were selected. Procedural and clinical characteristics were similar between the groups. In-hospital mortality was similar in both tested groups. One-year follow-up demonstrated comparable efficacy outcome TVR (BP-SES 7.1% vs. DP-EES 5.2%, p = 0.14), as well as similar safety outcomes of all-cause death, myocardial infarction, and definite/probable stent thrombosis. Conclusions: The thin-strut biodegradable polymer coated sirolimus-eluting stent demonstrated comparable clinical outcomes at 1 year after implantation to the DP-EES. These data support the relative safety and efficacy of BP-SES in AMI patients undergoing percutaneous coronary intervention.
引用
下载
收藏
页码:347 / 355
页数:9
相关论文
共 50 条
  • [1] Biodegradable polymer-coated thin strut sirolimus-eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population
    Gasior, Pawel
    Gierlotka, Marek
    Szczurek-Katanski, Krzysztof
    Osuch, Marcin
    Roleder, Magda
    Hawranek, Michal
    Wojakowski, Wojciech
    Polonski, Lech
    CARDIOLOGY JOURNAL, 2021, 28 (02) : 235 - 243
  • [2] Biodegradable Polymer-Coated Sirolimus-Eluting Stent Implantation in Acute Myocardial Infarction
    Yang Shengli
    Liu Huiliang
    Han Yalin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B6 - B7
  • [3] Angioscopic Comparison of Arterial Repair Between Biodegradable Polymer-Coated Biolimus A9-Eluting Stent and Durable Polymer-Coated Sirolimus-Eluting Stent in Patients
    Awata, Masaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Iida, Osamu
    Shin, Okamoto
    Tanaka, Nobuaki
    Dohi, Tomoharu
    Mishima, Tsuyoshi
    Mizugami, Yukika
    Nanto, Kiyonori
    Ishida, Yoshio
    Nanto, Shinsuke
    Uematsu, Masaaki
    Nagata, Seiki
    CIRCULATION, 2010, 122 (21)
  • [4] Bioresorbable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in daily clinical practice: propensity matched one-year results from interventional cardiology network registry
    Gasior, Pawel
    Gierlotka, Marek
    Szuczrek-Katanski, Krzysztof
    Osuch, Marcin
    Gnot, Roman
    Dydon, Agata
    Hawranek, Michal
    Lekston, Andrzej
    Gasior, Mariusz
    Polonski, Lech
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B315 - B316
  • [5] Ultrathin, Biodegradable-Polymer Sirolimus-Eluting Stent vs Thin, Durable-Polymer Everolimus-Eluting Stent
    Nakamura, Masato
    Kadota, Kazushige
    Nakagawa, Yoshihisa
    Tanabe, Kengo
    Ito, Yoshiaki
    Amano, Tetsuya
    Maekawa, Yuichiro
    Takahashi, Akihiko
    Shiode, Nobuo
    Otsuka, Yoritaka
    Kawasaki, Tomohiro
    Hikichi, Yutaka
    Shite, Junya
    Kozuma, Ken
    Iijima, Raisuke
    Murakami, Yoshitaka
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (13) : 1324 - 1334
  • [6] Bioresorbable polymer-coated thin strut sirolimus-eluting stent vs durable polymer-coated everolimus-eluting stent in daily clinical practice: Propensity matched one-year results from interventional cardiology network registry
    Gasior, Pawel
    Gierlotka, Marek
    Szczurek-Katanski, Krzysztof
    Osuch, Marcin
    Gnot, Roman
    Hawranek, Michal
    Gasior, Mariusz
    Polonski, Lech
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (07) : E362 - E368
  • [7] Angioscopic Assessment of Arterial Repair Following Biodegradable Polymer-Coated Biolimus A9-Eluting Stent Implantation - Comparison With Durable Polymer-Coated Sirolimus-Eluting Stent
    Awata, Masaki
    Uematsu, Masaaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Onishi, Toshinari
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Nagata, Seiki
    CIRCULATION JOURNAL, 2011, 75 (05) : 1113 - 1119
  • [8] Clinical outcome of biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with diabetes
    Kakizaki, Ryota
    Minami, Yoshiyasu
    Katamine, Masahiro
    Katsura, Aritomo
    Muramatsu, Yusuke
    Hashimoto, Takuya
    Meguro, Kentaro
    Shimohama, Takao
    Ako, Junya
    CARDIOVASCULAR DIABETOLOGY, 2020, 19 (01)
  • [9] Clinical outcome of biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with diabetes
    Ryota Kakizaki
    Yoshiyasu Minami
    Masahiro Katamine
    Aritomo Katsura
    Yusuke Muramatsu
    Takuya Hashimoto
    Kentaro Meguro
    Takao Shimohama
    Junya Ako
    Cardiovascular Diabetology, 19
  • [10] Late restenosis in patients receiving a polymer-coated sirolimus-eluting stent
    Wessely, R
    Kastrati, A
    Schömig, A
    ANNALS OF INTERNAL MEDICINE, 2005, 143 (05) : 392 - 394