Treatment of Complex Intracranial Aneurysms Using Flow-Diverting Silk® Stents An Analysis of 32 Consecutive Patients

被引:15
|
作者
Buyukkaya, Ramazan [1 ]
Kocaeli, Hasan [2 ]
Yildirim, Nalan [3 ]
Cebeci, Hakan [3 ]
Erdogan, Cuneyt [3 ]
Hakyemez, Bahattin [3 ]
机构
[1] Duzce Univ, Sch Med, Dept Radiol, TR-81100 Duzce, Turkey
[2] Uludag Univ, Sch Med, Dept Neurosurg, Bursa, Turkey
[3] Uludag Univ, Sch Med, Dept Radiol, Bursa, Turkey
关键词
cerebral aneurysms; flow diverter; Silk stent; endovascular treatment; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; EMBOLIZATION DEVICE; FOLLOW-UP; EXPERIENCE; RECONSTRUCTION; EFFICACY; ARTERY; SAFETY;
D O I
10.15274/INR-2014-10070
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study describes the pen-procedural and late complications and angiographic follow-up results of 32 patients with 34 complex aneurysms treated with flow diverter Silk stents in a single centre. In this retrospective study, 40 Silk stents (SS) were implanted in 34 complex intracranial aneurysms in 32 patients. In our series, 20 (58.8%) carotid-ophthalmic internal carotid artery (ICA), six (17.6%) cavernous ICA, two (5.9%) supraclinoid ICA, two (5.9%) petrosal ICA (the same patient-bilateral) and four (11.8%) posterior circulation aneurysms were treated. One of the posterior circulation lesions was a fenestrated-type aneurysm. Twenty wide-necked, saccular; eight neck remnant; four fusiform and two blister-like aneurysms were included in our series. SS were successfully implanted in all patients (100%). Mis-deployment occurred in 17.6% of patients. In two of these patients adequate stent openness was achieved via Hyperglide balloon dilatation. Coil embolization in addition to SS placement was utilized in four aneurysms. One patient (3%) experienced transient morbidity due to a thromboembolic event and there was one mortality (3%) due to remote intraparenchymal haemorrhage. Complete occlusion of 27/33 (81.8 %) and 29/33 (87.9 %) aneurysms was achieved six and 12 months after the procedure, respectively. In-stent intimal hyperplasia was detected in 6.1 % patients. Flow-diverter Silk stent implantation is an effective method of treating complex aneurysms with acceptable mortality and morbidity rates. Complete occlusion is achieved in most of the complex aneurysms.
引用
收藏
页码:729 / 735
页数:7
相关论文
共 50 条
  • [41] Hemodynamic Analysis of Postoperative Rupture of Unruptured Intracranial Aneurysms after Placement of Flow-Diverting Stents: A Matched Case-Control Study
    Li, W.
    Tian, Z.
    Zhu, W.
    Zhang, Y. S.
    Wang, K.
    Zhang, Y.
    Wang, Y.
    Yang, X.
    Liu, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (11) : 1916 - 1923
  • [42] The Effect of Placing Flow-Diverting Stents in Intracranial Collateral Arteries of Miniature Pig
    Wang, Jiwei
    Ding, Yanan
    Wang, Qiuxia
    Wang, Yanan
    Mu, Shiqing
    Bi, Lixin
    Li, Youxiang
    MEDICAL SCIENCE MONITOR, 2017, 23 : 1428 - 1435
  • [43] The efficacy and safety of flow-diverting device and coil embolization for intracranial aneurysms: a meta-analysis
    Guo, Z.
    Wang, K.
    Kadeer, K.
    Cheng, X-J
    Aisha, M.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2021, 25 (17) : 5383 - 5391
  • [44] A pilot validation of CFD model results against PIV observations of haemodynamics in intracranial aneurysms treated with flow-diverting stents
    Li, Yujie
    Verrelli, David I.
    Yang, William
    Qian, Yi
    Chong, Winston
    JOURNAL OF BIOMECHANICS, 2020, 100
  • [45] Small Unruptured Intracranial Aneurysms Can Be Effectively Treated With Flow-Diverting Devices
    Li, Li
    Gao, Bu-Lang
    Shao, Qiu-Ji
    Zhang, Guang-Lin
    Wang, Zi-Liang
    Li, Tian-Xiao
    Zhu, Liang-Fu
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [46] The Pipeline Flow-Diverting Stent for Exclusion of Ruptured Intracranial Aneurysms With Difficult Morphologies
    Martin, Allan R.
    Cruz, Juan Pablo
    Matouk, Charles C.
    Spears, Julian
    Marotta, Thomas R.
    NEUROSURGERY, 2012, 70
  • [47] Cerebral Aneurysms Treated with Flow-Diverting Stents: Computational Models with Intravascular Blood Flow Measurements
    Levitt, M. R.
    McGah, P. M.
    Aliseda, A.
    Mourad, P. D.
    Nerva, J. D.
    Vaidya, S. S.
    Morton, R. P.
    Ghodke, B. V.
    Kim, L. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (01) : 143 - 148
  • [48] DynaCT imaging for intraprocedural evaluation of flow-diverting stent apposition during endovascular treatment of intracranial aneurysms
    Ding, Dale
    Starke, Robert M.
    Durst, Christopher R.
    Gaughen, John R., Jr.
    Evans, Avery J.
    Jensen, Mary E.
    Liu, Kenneth C.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (11) : 1981 - 1983
  • [49] Multiphysics coupling numerical simulation of flow-diverting stents in the treatment of patients with pulsatile tinnitus
    Mu, Zhenxia
    Liu, Li
    Sun, Yufeng
    Gao, Bin
    Lv, Han
    Zhao, Pengfei
    Liu, Youjun
    Wang, Zhenchang
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (12)
  • [50] Aortic Aneurysm Rupture Following Treatment With Flow-Diverting Multilayer Stents
    Antoniou, George A.
    Papas, Theofanis T.
    Ioannis, Mazarakis
    Tsagkos, Ioannis
    Trachanellis, Sofoklis
    Bessias, Nikos
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (06) : 872 - 874