Small Unruptured Intracranial Aneurysms Can Be Effectively Treated With Flow-Diverting Devices

被引:4
|
作者
Li, Li [1 ]
Gao, Bu-Lang [1 ]
Shao, Qiu-Ji [1 ]
Zhang, Guang-Lin [1 ]
Wang, Zi-Liang [1 ]
Li, Tian-Xiao [1 ]
Zhu, Liang-Fu [1 ]
机构
[1] Zhengzhou Univ, Henan Prov Peoples Hosp, Zhengzhou, Peoples R China
来源
FRONTIERS IN NEUROLOGY | 2022年 / 13卷
关键词
flow diverter; intracranial aneurysms; unruptured; small; complications; PIPELINE EMBOLIZATION DEVICE; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; MULTICENTER; COMPLICATIONS; THERAPY; COILING; SAFETY; RECONSTRUCTION; EFFICACY;
D O I
10.3389/fneur.2022.913653
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeTo investigate the effect and safety of flow diverters in the management of small (<10 mm in diameter) unruptured intracranial aneurysms. Materials and MethodsOne hundred and ten patients with 145 small intracranial aneurysms treated with flow diverters were retrospectively enrolled. The clinical, endovascular, and follow-up data were analyzed. ResultsOne hundred twenty-one flow diverters were deployed for the treatment of 145 small intracranial aneurysms in 110 patients, and the stenting success rate was 99.1%. In 133 (91.7%) aneurysms, only flow-diverting devices were deployed, and in the rest 12 (8.3%) of aneurysms, coils were used to loosely pack the aneurysm after deployment of a flow-diverting device. Five patients (4.5%) experienced ischemic complications, but no hemorrhagic complications were occurred. All patients had clinical follow-up 6-18 (median 12) after the procedure, with the modified Rankin scale score (mRS) 0 in 101 patients, 1 in four patients, 2 in three patients, 4 in one patient, and 5 in one patient. Digital subtraction angiography was performed at follow-up in 90 (81.8%) patients with 118 (81.4%) aneurysms 6-18 months (median 12) after the procedure, with the Raymond grade I in 90 (76.2%) aneurysms and Raymond grade III in 28 (23.7%). Eighteen patients with 22 partially occluded aneurysms at the first angiographic follow-up experienced the second digital subtraction angiography 12-36 months (median 26) after the procedure, and 21 (95.5%) aneurysms were completely occluded. Two patients had asymptomatic in-stent stenosis. ConclusionTreatment of small unruptured intracranial aneurysms with flow diverters can be performed safely and effectively with satisfactory outcomes.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Modeling Fibrin Accumulation on Flow-Diverting Devices for Intracranial Aneurysms
    Cebral, Juan R.
    Mut, Fernando
    Löhner, Rainald
    Marsh, Laurel
    Chitsaz, Alireza
    Bilgin, Cem
    Bayraktar, Esref
    Kallmes, David
    Kadirvel, Ramanathan
    International Journal for Numerical Methods in Biomedical Engineering, 40 (12):
  • [2] Modeling Fibrin Accumulation on Flow-Diverting Devices for Intracranial Aneurysms
    Cebral, Juan R.
    Mut, Fernando
    Loehner, Rainald
    Marsh, Laurel
    Chitsaz, Alireza
    Bilgin, Cem
    Bayraktar, Esref
    Kallmes, David
    Kadirvel, Ramanathan
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (12)
  • [3] SILK Flow-Diverting Device for Intracranial Aneurysms
    Binning, Mandy J.
    Natarajan, Sabareesh K.
    Bulsara, Ketan R.
    Siddiqui, Adnan H.
    Hopkins, L. Nelson
    Levy, Elad I.
    WORLD NEUROSURGERY, 2011, 76 (05) : 477.e1 - 477.e6
  • [4] Analysis of Flow Dynamics and Outcomes of Cerebral Aneurysms Treated with Intrasaccular Flow-Diverting Devices
    Cebral, J. R.
    Chung, B. J.
    Mut, F.
    Chudyk, J.
    Bleise, C.
    Scrivano, E.
    Lylyk, P.
    Kadirvel, R.
    Kallmes, D.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (09) : 1511 - 1516
  • [5] Research progress on complications of intracranial aneurysms with flow-diverting stents
    Yu, Jinlu
    Shi, Lei
    Yuan, Yongjie
    Wu, Wei
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (07): : 13340 - 13350
  • [6] Fluid dynamics in intracranial aneurysms treated with flow-diverting stents: effect of multiple geometrical parameters
    Chassagne, Fanette
    Barbour, Michael C.
    Levitt, Michael R.
    Aliseda, Alberto
    JOURNAL OF FLUID MECHANICS, 2023, 973
  • [7] National Survey on Flow-Diverting Stents for Intracranial Aneurysms in the United States
    Salem, Mohamed M.
    Elfil, Mohamed
    Aboutaleb, Pakinam E.
    Dmytriw, Adam A.
    Thomas, Ajith J.
    Hassan, Ameer E.
    Mascitelli, Justin R.
    Kan, Peter
    Jankowitz, Brian T.
    Burkhardt, Jan-Karl
    WORLD NEUROSURGERY, 2022, 166 : E958 - E967
  • [8] Observer Variability of an Angiographic Grading Scale Used for the Assessment of Intracranial Aneurysms Treated with Flow-Diverting Stents
    Joshi, M. D.
    O'Kelly, C. J.
    Krings, T.
    Fiorella, D.
    Marotta, T. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (08) : 1589 - 1592
  • [9] Flow-diverting devices in the treatment of unruptured ophthalmic segment aneurysms at a mean clinical follow-up of 5 years
    Przemysław Kunert
    Katarzyna Wójtowicz
    Jarosław Żyłkowski
    Maciej Jaworski
    Daniel Rabczenko
    Jakub Wojciechowski
    Kamil Leśniewski
    Andrzej Marchel
    Scientific Reports, 11
  • [10] Nursing care of 22 patients with complex intracranial aneurysms treated with flow-diverting stents:A retrospective study
    Wenli Zhao
    Huizhen Peng
    Hongmei Zhang
    Tianxiao Li
    Journal of Interventional Medicine, 2019, 2 (03) : 128 - 130