Treatment of Complex Intracranial Aneurysms Using Flow-Diverting Silk® Stents An Analysis of 32 Consecutive Patients

被引:15
|
作者
Buyukkaya, Ramazan [1 ]
Kocaeli, Hasan [2 ]
Yildirim, Nalan [3 ]
Cebeci, Hakan [3 ]
Erdogan, Cuneyt [3 ]
Hakyemez, Bahattin [3 ]
机构
[1] Duzce Univ, Sch Med, Dept Radiol, TR-81100 Duzce, Turkey
[2] Uludag Univ, Sch Med, Dept Neurosurg, Bursa, Turkey
[3] Uludag Univ, Sch Med, Dept Radiol, Bursa, Turkey
关键词
cerebral aneurysms; flow diverter; Silk stent; endovascular treatment; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; EMBOLIZATION DEVICE; FOLLOW-UP; EXPERIENCE; RECONSTRUCTION; EFFICACY; ARTERY; SAFETY;
D O I
10.15274/INR-2014-10070
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study describes the pen-procedural and late complications and angiographic follow-up results of 32 patients with 34 complex aneurysms treated with flow diverter Silk stents in a single centre. In this retrospective study, 40 Silk stents (SS) were implanted in 34 complex intracranial aneurysms in 32 patients. In our series, 20 (58.8%) carotid-ophthalmic internal carotid artery (ICA), six (17.6%) cavernous ICA, two (5.9%) supraclinoid ICA, two (5.9%) petrosal ICA (the same patient-bilateral) and four (11.8%) posterior circulation aneurysms were treated. One of the posterior circulation lesions was a fenestrated-type aneurysm. Twenty wide-necked, saccular; eight neck remnant; four fusiform and two blister-like aneurysms were included in our series. SS were successfully implanted in all patients (100%). Mis-deployment occurred in 17.6% of patients. In two of these patients adequate stent openness was achieved via Hyperglide balloon dilatation. Coil embolization in addition to SS placement was utilized in four aneurysms. One patient (3%) experienced transient morbidity due to a thromboembolic event and there was one mortality (3%) due to remote intraparenchymal haemorrhage. Complete occlusion of 27/33 (81.8 %) and 29/33 (87.9 %) aneurysms was achieved six and 12 months after the procedure, respectively. In-stent intimal hyperplasia was detected in 6.1 % patients. Flow-diverter Silk stent implantation is an effective method of treating complex aneurysms with acceptable mortality and morbidity rates. Complete occlusion is achieved in most of the complex aneurysms.
引用
收藏
页码:729 / 735
页数:7
相关论文
共 50 条
  • [21] Actual Metal Coverage at the Neck Is Critical for Flow-Diverting Stents in Treating Intracranial Aneurysms REPLY
    van den Berg, R.
    Schneiders, J. J.
    Ferns, S. P.
    Majoie, C. B.
    Vanbavel, E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (03) : E33 - E33
  • [22] Flow-diverting stents for the treatment of unruptured distal anterior cerebral artery aneurysms: analysis of the CRETA Registry
    Scarcia, Luca
    Clarencon, Frederic
    Dmytriw, Adam A.
    Shotar, Eimad
    Premat, Kevin
    Jabbour, Pascal
    Tjoumakaris, Stavropoula, I
    Gooch, Reid
    Psychogios, Marios-Nikos
    Ntoulias, Nikolaos
    Sporns, Peter B.
    Puri, Ajit S.
    Singh, Jasmeet
    Kuhn, Anna Luisa
    Hassan, Ameer E.
    Algin, Oktay
    Moehlenbruch, Markus A.
    Hohenstatt, Sophia
    Russo, Riccardo
    Bergui, Mauro
    Goren, Oded
    Kole, Matthew J.
    Bankole, Nourou Dine Adeniran
    Bibi, Richard
    Boulouis, Gregoire
    Morimoto, Takeshi
    Sakakibara, Fumihiro
    Pop, Raoul
    Juravle, Ciprian
    Ho, Joanna W. K.
    Ferrario, Angel
    Pujol Lereis, Virginia
    Cooper, Jared
    Gandhi, Chirag D.
    Salsano, Giancarlo
    Castellan, Lucio
    Camilli, Arianna
    Consoli, Arturo
    Sgreccia, Alessandro
    Raz, Eytan
    Chung, Charlotte
    Burel, Julien
    Papagiannaki, Chrysanthi
    Rasheed, Umair
    Baqir Hassan, Khawaja Muhammad
    Hong, Tao
    Ji, Zhe
    Rautio, Riitta
    Sinislao, Matias
    Ruggiero, Maria
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024,
  • [23] Modeling Fibrin Accumulation on Flow-Diverting Devices for Intracranial Aneurysms
    Cebral, Juan R.
    Mut, Fernando
    Löhner, Rainald
    Marsh, Laurel
    Chitsaz, Alireza
    Bilgin, Cem
    Bayraktar, Esref
    Kallmes, David
    Kadirvel, Ramanathan
    International Journal for Numerical Methods in Biomedical Engineering, 40 (12):
  • [24] Modeling Fibrin Accumulation on Flow-Diverting Devices for Intracranial Aneurysms
    Cebral, Juan R.
    Mut, Fernando
    Loehner, Rainald
    Marsh, Laurel
    Chitsaz, Alireza
    Bilgin, Cem
    Bayraktar, Esref
    Kallmes, David
    Kadirvel, Ramanathan
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (12)
  • [25] Early experience with flow diverting endoluminal stents for the treatment of intracranial aneurysms
    Walcott, Brian P.
    Pisapia, Jared M.
    Nahed, Brian V.
    Kahle, Kristopher T.
    Ogilvy, Christopher S.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (07) : 891 - 894
  • [26] Observer Variability of an Angiographic Grading Scale Used for the Assessment of Intracranial Aneurysms Treated with Flow-Diverting Stents
    Joshi, M. D.
    O'Kelly, C. J.
    Krings, T.
    Fiorella, D.
    Marotta, T. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (08) : 1589 - 1592
  • [27] Effect of intracranial aneurysm characteristics on complications from endovascular treatment with flow-diverting stents
    Ding, Dale
    BRITISH JOURNAL OF NEUROSURGERY, 2014, 28 (01) : 138 - 138
  • [28] Platelet Dynamics and Hemodynamics of Cerebral Aneurysms Treated with Flow-Diverting Stents
    Marsh, Laurel M. M.
    Barbour, Michael C.
    Chivukula, Venkat Keshav
    Chassagne, Fanette
    Kelly, Cory M.
    Levy, Samuel H.
    Kim, Louis J.
    Levitt, Michael R.
    Aliseda, Alberto
    Annals of Biomedical Engineering, 2020, 48 (01): : 490 - 501
  • [29] Potential role of flow-diverting stents for posterior cerebral artery aneurysms
    Ding, Dale
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2014, 116 : 106 - 107
  • [30] Platelet Dynamics and Hemodynamics of Cerebral Aneurysms Treated with Flow-Diverting Stents
    Marsh, Laurel M. M.
    Barbour, Michael C.
    Chivukula, Venkat Keshav
    Chassagne, Fanette
    Kelly, Cory M.
    Levy, Samuel H.
    Kim, Louis J.
    Levitt, Michael R.
    Aliseda, Alberto
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (01) : 490 - 501