摘要
Purpose: In this study, we investigate a technique of matching internal target volumes (ITVs) in four-dimensional (4D) simulation computed tomography (CT) to the composite target volume in free-breathing on-board cone-beam (CB) CT. The technique is illustrated by using both phantom and patient cases. Methods and Materials: A dynamic phantom with a target ball simulating respiratory motion with various amplitude and cycle times was used to verify localization accuracy. The dynamic phantom was scanned using simulation CT with a phase-based retrospective sorting technique. The ITV was then determined based on 10 sets of sorted images. The size and epicenter of the ITV identified from 4D simulation CT images and the composite target volume identified from on-board CBCT images were compared to assess localization accuracy. Similarly, for two clinical cases of patients with lung cancer, ITVs defined from 4D simulation CT images and CBCT images were compared. Results: For the phantom, localization accuracy between the ITV in 4Dsimulation CT and the composite target volume in CBCT was within 1 mm, and ITV was within 8.7%. For patient cases, ITVs on simulation CT and CBCT were within 8.0%. Conclusion: This study shows that CBCT is a useful tool to localize ITV for targets affected by respiratory motion. Verification of the ITV from 4D simulation CT using on-board free-breathing CBCT is feasible for the target localization of lung tumors. (c) 2007 Elsevier Inc.
引用
收藏
页码:1618 / 1624
页数:7
相关论文
共 50 条
  • [41] Complexities of lung stereotactic radiotherapy planning target volumes
    Dawood, Omar
    Chang, Joe Y.
    Balter, Peter A.
    Komaki, Ritsuko
    Roth, Jack A.
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2009, 4 (09) : S941 - S942
  • [42] Mobile Cone-Beam CT-Assisted Bronchoscopy for Peripheral Lung Lesions
    Salahuddin, Moiz
    Bashour, Sami I. I.
    Khan, Asad
    Chintalapani, Gouthami
    Kleinszig, Gerhard
    Casal, Roberto F. F.
    [J]. DIAGNOSTICS, 2023, 13 (05)
  • [43] Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors
    Guckenberger, Matthias
    Meyer, Juergen
    Wilbert, Juergen
    Baier, Kurt
    Mueller, Gerd
    Wulf, Joern
    Flentje, Michael
    [J]. ACTA ONCOLOGICA, 2006, 45 (07) : 897 - 906
  • [44] Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: Localization, verification, and intrafraction tumor position
    Purdie, Thomas G.
    Bissonnette, Jean-Pierre
    Franks, Kevin
    Bezjak, Andrea
    Payne, David
    Sie, Fanny
    Sharpe, Michael B.
    Jaffray, David A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (01): : 243 - 252
  • [45] Feasibility of using cone-beam CT to verify and reposition the optically guided target localization of linear accelerator based stereotactic radiosurgery
    Zhu, Jingeng
    [J]. MEDICAL PHYSICS, 2011, 38 (01) : 390 - 396
  • [46] Impact of Immobilization on Intra-fraction Motion for Spine Stereotactic Body Radiotherapy (SBRT) using Cone-beam CT (CBCT)
    Li, W.
    Sahgal, A.
    Foote, M.
    Millar, B.
    Jaffray, D.
    Letoumeau, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S775 - S775
  • [47] IMPACT OF IMMOBILIZATION ON INTRA-FRACTION MOTION FOR SPINE STEREOTACTIC BODY RADIOTHERAPY (SBRT) USING CONE-BEAM CT (CBCT)
    Li, W.
    Sahgal, A.
    Foote, M.
    Millar, B-A.
    Jaffray, D.
    Letourneau, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S32 - S32
  • [48] On-line image guidance for frameless stereotactic radiotherapy of lung malignancies by cone beam CT: Comparison between target localization and alignment on bony anatomy
    Masi, Laura
    Casamassima, Franco
    Menichelli, Claudia
    Pasciuti, Katia
    Doro, Raffaela
    Polli, Caterina
    D'Imporzano, Elena
    Bonucci, Ivano
    [J]. ACTA ONCOLOGICA, 2008, 47 (07) : 1422 - 1431
  • [49] Comparison of internal target volumes defined on three-dimensional CT, four-dimensional CT and cone-beam CT images of non-small-cell lung cancer
    Li, F.
    Li, J.
    Zhang, Y.
    Xing, J.
    Shang, D.
    Yu, N.
    [J]. EUROPEAN JOURNAL OF CANCER, 2013, 49 : S220 - S220
  • [50] The dosimetric impact of translation-only setup correction in cone-beam CT-guided stereotactic radiotherapy for lung tumors
    Suen, A. W.
    Chao, K.
    Grills, I. S.
    Yan, D.
    Kestin, L. L.
    Martinez, A. A.
    Hugo, G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S633 - S634