IMPACT OF IMMOBILIZATION ON INTRA-FRACTION MOTION FOR SPINE STEREOTACTIC BODY RADIOTHERAPY (SBRT) USING CONE-BEAM CT (CBCT)

被引:0
|
作者
Li, W. [1 ]
Sahgal, A. [2 ]
Foote, M. [2 ]
Millar, B-A. [2 ]
Jaffray, D. [2 ]
Letourneau, D. [2 ]
机构
[1] Princess Margaret Hosp, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
97
引用
收藏
页码:S32 / S32
页数:1
相关论文
共 50 条
  • [1] Impact of Immobilization on Intra-fraction Motion for Spine Stereotactic Body Radiotherapy (SBRT) using Cone-beam CT (CBCT)
    Li, W.
    Sahgal, A.
    Foote, M.
    Millar, B.
    Jaffray, D.
    Letoumeau, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S775 - S775
  • [2] ASSESSMENT OF INTRA-FRACTION TARGET POSITION ACCURACY FOR LUNG STEREOTACTIC BODY RADIOTHERAPY (SBRT) USING CONE-BEAM CT (CBCT)
    Li, W.
    Bezjak, A.
    Purdie, T.
    Taremi, M.
    Hope, A.
    Brade, A.
    Sun, A.
    Cho, J.
    Jaffray, D.
    Bissonnette, J. P.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S26 - S27
  • [3] Cone-beam CT (CBCT) assessment of intra-fraction motion during stereotactic body radiotherapy (SBRT) for non-small cell lung cancer (NSCLC)
    Qureshi, A.
    Hartill, C.
    Landau, D.
    Ahmad, S.
    LUNG CANCER, 2011, 71 : S32 - S32
  • [4] Intra-Fraction Motion Monitoring for Spine SBRT Patients Using KV Cone-Beam Projections
    Markel, D.
    Letourneau, D.
    Keller, H.
    Becker, N.
    Shultz, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E169 - E169
  • [5] Quantifying inter and intra-fraction tumor motion using respiration-correlated cone beam CT in lung stereotactic body radiotherapy (SBRT)
    Franks, K. N.
    Purdie, T. G.
    Bezjak, A.
    Moseley, D.
    Pearson, S.
    Jaffrayl, D. A.
    Bissonnette, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S489 - S490
  • [6] Dose Calculation Accuracy Using Cone-Beam CT (CBCT) for Lung Stereotactic Body Radiotherapy (SBRT)
    Xiong, W.
    Huang, Y.
    Gewanter, R.
    Dutta, P.
    Burman, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Intrafractional Target Position Accuracy for Lung Stereotactic Body Radiotherapy (SBRT) using Cone-beam CT (CBCT)
    Li, W.
    Bezjak, A.
    Purdie, T. G.
    Taremi, M.
    Hope, A.
    Brade, A.
    Sun, A.
    Cho, J.
    Jaffray, D. A.
    Bissonnette, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S160 - S161
  • [8] Inter- and intra-fraction motion in stereotactic body radiotherapy for spinal and paraspinal tumours using cone-beam CT and positional correction in six degrees of freedom
    Finnigan, Renee
    Lamprecht, Brock
    Barry, Tamara
    Jones, Kimberley
    Boyd, Joshua
    Pullar, Andrew
    Burmeister, Bryan
    Foote, Matthew
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (01) : 112 - 118
  • [9] Evaluation of Initial Setup Accuracy and Intra-Fraction Motion for Spine SBRT Using Stereotactic Body Frames
    Hacker, F.
    Bondeson, J.
    Lewis, J.
    Mannarino, E.
    Friesen, S.
    Balboni, T.
    Alexander, B.
    Sher, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3796 - 3796
  • [10] Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography
    Li, Winnie
    Sahgal, Arjun
    Foote, Matthew
    Millar, Barbara-Ann
    Jaffray, David A.
    Letourneau, Daniel
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (02): : 520 - 526