IMPACT OF IMMOBILIZATION ON INTRA-FRACTION MOTION FOR SPINE STEREOTACTIC BODY RADIOTHERAPY (SBRT) USING CONE-BEAM CT (CBCT)

被引:0
|
作者
Li, W. [1 ]
Sahgal, A. [2 ]
Foote, M. [2 ]
Millar, B-A. [2 ]
Jaffray, D. [2 ]
Letourneau, D. [2 ]
机构
[1] Princess Margaret Hosp, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
97
引用
收藏
页码:S32 / S32
页数:1
相关论文
共 50 条
  • [31] Target Relocalization Accuracy and PTV Margin Verification Using Three-Dimensional Cone-Beam Computed Tomography (CBCT) in Stereotactic Body Radiotherapy (SBRT) of Lung Cancers
    Wang, L.
    Feigenberg, S.
    Lally, B.
    Fan, J.
    Jin, L.
    Chen, L.
    Price, R.
    Ma, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [32] PATIENT POSITIONING DURING AND AFTER STEREOTACTIC BODY RADIOTHERAPY (SBRT) FOR NON-SMALL CELL LUNG CANCER (NSCLC) USING CONE-BEAM COMPUTED TOMOGRAPHY (CBCT)
    Qureshi, Asad
    Hughes, Simon
    Landau, David
    Hartill, Clare
    Barnett, Keely
    Wildermuth, Kate
    Gammie, Alison
    Ahmad, Shahreen
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S817 - S817
  • [33] Single-Isocenter, Multiple-Target Abdominal Cone-Beam Computed Tomography (CBCT)-Guided Online Adaptive Stereotactic Body Radiotherapy (SBRT)
    Raranje, Chipo
    Mazur, Thomas R.
    Mo, Allen
    Laugeman, Eric
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [34] Image-Guidance Using Cone-Beam CT for Stereotactic Body Radiotherapy (SBRT) of Lung Cancer Patients: Bony Alignment Or Soft Tissue Alignment?
    Wang, L.
    Turaka, A.
    Meyer, J.
    Spoka, D.
    Jin, L.
    Fan, J.
    Ma, C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3657 - 3657
  • [35] Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images
    Marchant, T. E.
    Amer, A. M.
    Moore, C. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (04): : 1087 - 1098
  • [36] Clinical Evaluation of Positioning Accuracy of Two Immobilization Devices for Stereotactic Body Radiotherapy Using Cone Beam CT
    Cao, M.
    Cao, N.
    Cardenes, H.
    Fakiris, A.
    Desrosiers, C.
    Das, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3691 - 3692
  • [37] Inter and intra-fraction target localization using volumetric imaging in stereotactic body radiation therapy (SBRT) in the lung
    Purdie, T. G.
    Franks, K. N.
    Bezjak, A.
    Higgins, J.
    Jaffray, D. A.
    Bissonnette, J. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S705 - S705
  • [38] Cone-beam CT (CBCT) image-guided radiotherapy (IGRT) significantly reduces margins required for stereotactic
    Grills, I.
    Kestin, L.
    Yan, D.
    Chao, K.
    Wloch, J.
    Hugo, G.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S62 - S62
  • [39] Single Fraction Spine SBRT Utilizing Cone-Beam CT Image-Guidance and the HexaPOD Robotic Couch
    Hyde, D.
    Korol, R.
    Davidson, M.
    Lochray, F.
    Ma, L.
    Sahgal, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [40] Stereotactic radiosurgery for intradural spine tumors using cone-beam CT image guidance
    Monserrate, Andres
    Zussman, Benjamin
    Ozpinar, Alp
    Niranjan, Ajay
    Flickinger, John C.
    Gerszten, Peter C.
    NEUROSURGICAL FOCUS, 2017, 42 (01)