Cone-beam CT localization of internal target volumes for stereotactic body radiotherapy of lung lesions

被引:49
|
作者
Wang, Zhiheng [1 ]
Wu, Q. Jackie [1 ]
Marks, Lawrence B. [1 ]
Larrier, Nicole [1 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
cone-beam computed tomography; internal target volume; stereotactic body radiotherapy; four-dimensional computed tomography; organ motion;
D O I
10.1016/j.ijrobp.2007.08.030
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In this study, we investigate a technique of matching internal target volumes (ITVs) in four-dimensional (4D) simulation computed tomography (CT) to the composite target volume in free-breathing on-board cone-beam (CB) CT. The technique is illustrated by using both phantom and patient cases. Methods and Materials: A dynamic phantom with a target ball simulating respiratory motion with various amplitude and cycle times was used to verify localization accuracy. The dynamic phantom was scanned using simulation CT with a phase-based retrospective sorting technique. The ITV was then determined based on 10 sets of sorted images. The size and epicenter of the ITV identified from 4D simulation CT images and the composite target volume identified from on-board CBCT images were compared to assess localization accuracy. Similarly, for two clinical cases of patients with lung cancer, ITVs defined from 4D simulation CT images and CBCT images were compared. Results: For the phantom, localization accuracy between the ITV in 4Dsimulation CT and the composite target volume in CBCT was within 1 mm, and ITV was within 8.7%. For patient cases, ITVs on simulation CT and CBCT were within 8.0%. Conclusion: This study shows that CBCT is a useful tool to localize ITV for targets affected by respiratory motion. Verification of the ITV from 4D simulation CT using on-board free-breathing CBCT is feasible for the target localization of lung tumors. (c) 2007 Elsevier Inc.
引用
收藏
页码:1618 / 1624
页数:7
相关论文
共 50 条
  • [1] Verifying internal target volume using cone-beam CT for stereotactic body radiotherapy treatment
    Wang, Z.
    Yin, F.
    Yoo, S.
    Wu, Q.
    Willett, C.
    Marks, L.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1991 - 1991
  • [2] The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy
    Clements, N.
    Kron, T.
    Franich, R.
    Dunn, L.
    Roxby, P.
    Aarons, Y.
    Chesson, B.
    Siva, S.
    Duplan, D.
    Ball, D.
    [J]. MEDICAL PHYSICS, 2013, 40 (02)
  • [3] Intrafractional Target Position Accuracy for Lung Stereotactic Body Radiotherapy (SBRT) using Cone-beam CT (CBCT)
    Li, W.
    Bezjak, A.
    Purdie, T. G.
    Taremi, M.
    Hope, A.
    Brade, A.
    Sun, A.
    Cho, J.
    Jaffray, D. A.
    Bissonnette, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S160 - S161
  • [4] CONE BEAM CT AND LUNG STEREOTACTIC BODY RADIOTHERAPY: TUMOR LOCALIZATION AND SETUP CONTROL
    De Rose, F.
    Mantini, G.
    Meduri, B.
    Balducci, M.
    D'Agostino, G. R.
    Mattiucci, G. C.
    Margaritora, S.
    Larici, A. R.
    Varone, F.
    Valentini, V.
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2010, 5 (05) : S111 - S111
  • [5] Deep Learning-Based Internal Target Volume (ITV) Prediction Using Cone-Beam CT Images in Lung Stereotactic Body Radiotherapy
    Li, Zhen
    Zhang, Shujun
    Zhang, Libo
    Li, Ya
    Zheng, Xiangpeng
    Fu, Jie
    Qiu, Jianjian
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [6] CONE-BEAM CT: LOCALIZZATION OF CLINICAL TARGET VOLUME IN LUNG STEREOTACTIC RADIOTHERAPY, PRELIMINARY RESULTS
    Giudice, E.
    Falco, M. D.
    Benassi, M.
    Ingrosso, G.
    Barbarino, R.
    Tortorelli, G.
    Hamoud, E.
    Santoni, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S340 - S340
  • [7] Cone-beam computed tomography imaging in stereotactic body radiotherapy allows for more than target localization
    Bakri, Bonnie
    Verbakel, Wilko
    Slotman, Ben
    Dahele, Max
    [J]. JOURNAL OF RADIOSURGERY AND SBRT, 2013, 2 (02): : 141 - 145
  • [8] Dose Calculation Accuracy Using Cone-Beam CT (CBCT) for Lung Stereotactic Body Radiotherapy (SBRT)
    Xiong, W.
    Huang, Y.
    Gewanter, R.
    Dutta, P.
    Burman, C.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [9] ASSESSMENT OF INTRA-FRACTION TARGET POSITION ACCURACY FOR LUNG STEREOTACTIC BODY RADIOTHERAPY (SBRT) USING CONE-BEAM CT (CBCT)
    Li, W.
    Bezjak, A.
    Purdie, T.
    Taremi, M.
    Hope, A.
    Brade, A.
    Sun, A.
    Cho, J.
    Jaffray, D.
    Bissonnette, J. P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S26 - S27
  • [10] Translational and rotational localization errors in cone-beam CT based image-guided lung stereotactic radiotherapy
    Garibaldi, Cristina
    Piperno, Gaia
    Ferrari, Annamaria
    Surgo, Alessia
    Muto, Matteo
    Ronchi, Sara
    Bazani, Alessia
    Pansini, Floriana
    Cremonesi, Marta
    Jereczek-Fossa, Barbara Alicja
    Orecchia, Roberto
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (07): : 859 - 865