Deep Learning-Based Internal Target Volume (ITV) Prediction Using Cone-Beam CT Images in Lung Stereotactic Body Radiotherapy

被引:0
|
作者
Li, Zhen [1 ,2 ]
Zhang, Shujun [1 ]
Zhang, Libo [1 ]
Li, Ya [1 ]
Zheng, Xiangpeng [1 ]
Fu, Jie [2 ]
Qiu, Jianjian [1 ]
机构
[1] Fudan Univ, Huadong Hosp, Shanghai, Peoples R China
[2] Shanghai Sixth Peoples Hosp, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
CBCT; 4DCT; deep learning; SBRT; Mask R-CNN; SCATTER CORRECTION; CANCER;
D O I
10.1177/15330338211073380
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose:This study aims to develop a deep learning (DL)-based (Mask R-CNN) method to predict the internal target volume (ITV) in cone beam computed tomography (CBCT) images for lung stereotactic body radiotherapy (SBRT) patients and to evaluate the prediction accuracy of the model using 4DCT as ground truth. Methods and Materials: This study enrolled 78 phantom cases and 156 patient cases who received SBRT treatment. We used a novel DL model (Mask R-CNN) to identify and delineate lung tumor ITV in CBCT images. The results of the DL-based method were compared quantitatively with the ground truth (4DCT) using 4 metrics, including Dice Similarity Coefficient (DSC), Relative Volume Index (RVI), 3D Motion Range (R-3D), and Hausdorff Surface Distance (HD). Paired t-tests were used to determine the differences between the DL-based method and manual contouring. Results: The DSC value for 4DCT(MIP) versus CBCT is 0.86 +/- 0.16 and for 4DCT(AVG) versus CBCT is 0.83 +/- 0.18, indicating a high similarity of tumor delineation in CBCT and 4DCT. The mean Accuracy Precision (mAP), R-3D, RVI, and HD values for phantom evaluation are 0.94 +/- 0.04, 1.37 +/- 0.36, 0.79 +/- 0.02, and 6.79 +/- 0.68, respectively. For patient evaluation, the mAP, R-3D, RVI, and HD achieved averaged values of 0.74 +/- 0.23, 2.39 +/- 1.59, 1.27 +/- 0.47, and 17.00 +/- 19.89, respectively. These results showed a good correlation between predicted ITV and manually contoured ITV. The phantom p-value for RVI, R-3D, and HD are 0.75, 0.08, 0.86, and patient p-value are 0.53, 0.07, 0.28, respectively. These p-values for phantom and patient showed no significant difference between the predicted ITV and physician's manual contouring. Conclusion:The current improved method (Mask R-CNN) yielded a good similarity between predicted ITV in CBCT and the manual contouring in 4DCT, thus indicating great potential for using CBCT for patient ITV contouring.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Dosimetric Study of Deep Learning-Guided ITV Prediction in Cone-beam CT for Lung Stereotactic Body Radiotherapy
    Zhang, Shujun
    Lv, Bo
    Zheng, Xiangpeng
    Li, Ya
    Ge, Weiqiang
    Zhang, Libo
    Mo, Fan
    Qiu, Jianjian
    [J]. FRONTIERS IN PUBLIC HEALTH, 2022, 10
  • [2] Verifying internal target volume using cone-beam CT for stereotactic body radiotherapy treatment
    Wang, Z.
    Yin, F.
    Yoo, S.
    Wu, Q.
    Willett, C.
    Marks, L.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1991 - 1991
  • [3] Cone-beam CT localization of internal target volumes for stereotactic body radiotherapy of lung lesions
    Wang, Zhiheng
    Wu, Q. Jackie
    Marks, Lawrence B.
    Larrier, Nicole
    Yin, Fang-Fang
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (05): : 1618 - 1624
  • [4] A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy
    Jin, JY
    Ajlouni, M
    Chen, Q
    Yin, FF
    Movsas, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 78 (02) : 177 - 184
  • [5] CONE-BEAM CT: LOCALIZZATION OF CLINICAL TARGET VOLUME IN LUNG STEREOTACTIC RADIOTHERAPY, PRELIMINARY RESULTS
    Giudice, E.
    Falco, M. D.
    Benassi, M.
    Ingrosso, G.
    Barbarino, R.
    Tortorelli, G.
    Hamoud, E.
    Santoni, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S340 - S340
  • [6] Intrafractional Target Position Accuracy for Lung Stereotactic Body Radiotherapy (SBRT) using Cone-beam CT (CBCT)
    Li, W.
    Bezjak, A.
    Purdie, T. G.
    Taremi, M.
    Hope, A.
    Brade, A.
    Sun, A.
    Cho, J.
    Jaffray, D. A.
    Bissonnette, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S160 - S161
  • [7] Evaluation of interfractional variation of the centroid position and volume of internal target volume during stereotactic body radiotherapy of lung cancer using cone-beam computed tomography
    Sun, Yanan
    Ge, Hong
    Cheng, Siguo
    Yang, Chengliang
    Zhu, Qianqian
    Li, Dingjie
    Tian, Yuan
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 461 - 472
  • [8] Adaptive Radiotherapy Via Deep Learning-Based Quantitative Cone-Beam CT Imaging
    Wan, L.
    Wu, H.
    Xu, S.
    Sun, B.
    Zhao, W.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E383 - E383
  • [9] Potentially Underestimating the Internal Target Volume (ITV) in Free-Breathing Cone-Beam CT (CBCT)
    Vergalasova, I.
    Maurer, J.
    Yin, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S672 - S672
  • [10] The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy
    Clements, N.
    Kron, T.
    Franich, R.
    Dunn, L.
    Roxby, P.
    Aarons, Y.
    Chesson, B.
    Siva, S.
    Duplan, D.
    Ball, D.
    [J]. MEDICAL PHYSICS, 2013, 40 (02)