Translational and rotational localization errors in cone-beam CT based image-guided lung stereotactic radiotherapy

被引:30
|
作者
Garibaldi, Cristina [1 ]
Piperno, Gaia [2 ]
Ferrari, Annamaria [2 ]
Surgo, Alessia [2 ]
Muto, Matteo [2 ]
Ronchi, Sara [2 ]
Bazani, Alessia [3 ]
Pansini, Floriana [3 ]
Cremonesi, Marta [1 ]
Jereczek-Fossa, Barbara Alicja [2 ,4 ]
Orecchia, Roberto [4 ,5 ]
机构
[1] European Inst Oncol, Unit Radiat Res, V Ripamonti 435, Milan, Italy
[2] European Inst Oncol, Dept Radiat Oncol, Milan, Italy
[3] European Inst Oncol, Unit Med Phys, Milan, Italy
[4] Univ Milan, Dept Hlth Sci, Milan, Italy
[5] European Inst Oncol, Milan, Italy
来源
关键词
Translational and rotational localization error; Lung SBRT; Image-guided radiotherapy; BODY RADIATION-THERAPY; X-RAY HEAD; TUMOR POSITION; BONY ANATOMY; GUIDANCE; CANCER; ACCURACY; PATIENT; SYSTEM; REGISTRATION;
D O I
10.1016/j.ejmp.2016.05.055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurate localization is crucial in delivering safe and effective stereotactic body radiation therapy (SBRT). The aim of this study was to analyse the accuracy of image-guidance using the cone-beam computed tomography (CBCT) of the VERO system in 57 patients treated for lung SBRT and to calculate the treatment margins. Materials and methods: The internal target volume (ITV) was obtained by contouring the tumor on maximum and mean intensity projection CT images reconstructed from a respiration correlated 4D-CT. Translational and rotational tumor localization errors were identified by comparing the manual registration of the ITV to the motion-blurred tumor on the CBCT and they were corrected by means of the robotic couch and the ring rotation. A verification CBCT was acquired after correction in order to evaluate residual errors. Results: The mean 3D vector at initial set-up was 6.6 +/- 2.3 mm, which was significantly reduced to 1.6 +/- 0.8 mm after 6D automatic correction. 94% of the rotational errors were within 3 degrees. The PTV margins used to compensate for residual tumor localization errors were 3.1, 3.5 and 3.3 mm in the LR, SI and AP directions, respectively. Conclusions: On-line image guidance with the ITV-CBCT matching technique and automatic 6D correction of the VERO system allowed a very accurate tumor localization in lung SBRT. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:859 / 865
页数:7
相关论文
共 50 条
  • [1] Prostate Image-Guided Radiotherapy by Megavolt Cone-Beam CT
    Zucca, Sergio
    Carau, Barbara
    Solla, Ignazio
    Garibaldi, Elisabetta
    Farace, Paolo
    Lay, Giancarlo
    Meleddu, Gianfranco
    Gabriele, Pietro
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 473 - 478
  • [2] Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy
    Grills, Inga S.
    Hugo, Geoffrey
    Kestfn, Larry L.
    Galerani, Ana Paula
    Chao, K. Kenneth
    Wloch, Jennifer
    Yan, Di
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1045 - 1056
  • [3] Cone-beam CT: Applications in image-guided external beam radiotherapy and brachytherapy
    Jaffray, DA
    Siewerdsen, JH
    Edmundson, GE
    Wong, JW
    Martinez, A
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2044 - 2044
  • [4] Multivariate Analysis of Translational and Rotational Corrections Applied in Cone-Beam CT Image-Guided Body Radiosurgery
    Flickinger, John
    Quader, Mubina
    Novotny, Josef
    Gerszten, Peter
    [J]. AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2010, 33 (02): : 213 - 214
  • [5] Towards optimization of megavoltage cone-beam CT for image-guided radiotherapy
    Pang, G
    O'Brien, P
    Mei, X
    Tambasco, M
    Yeboah, C
    Beachey, D
    Rowlands, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S623 - S623
  • [6] Patient dose in KV cone-beam CT image-guided radiotherapy
    Islam, M
    Purdie, T
    Moseley, D
    Alasti, H
    Norrlinger, B
    Sharpe, M
    Siewerdsen, J
    Jaffray, D
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1830 - 1830
  • [7] Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy
    Smitsmans, MHP
    de Bois, J
    Sonke, JJ
    Betgen, A
    Zijp, LJ
    Jaffray, DA
    Lebesque, JV
    van Herk, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (04): : 975 - 984
  • [8] Cone-beam CT (CBCT) image-guided radiotherapy (IGRT) significantly reduces margins required for stereotactic
    Grills, I.
    Kestin, L.
    Yan, D.
    Chao, K.
    Wloch, J.
    Hugo, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S62 - S62
  • [9] Deformable image registration in cone-beam CT images for image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Zhu, X.
    Garden, A.
    Ahamad, A.
    Ang, K.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1995 - 1995
  • [10] A personal perspective on the development and future of cone-beam CT for image-guided radiotherapy
    Jaffray, David A.
    [J]. MEDICAL PHYSICS, 2023, 50 : 54 - 57