Measuring 3D Hand and Finger Kinematics-A Comparison between Inertial Sensing and an Opto-Electronic Marker System

被引:19
|
作者
van den Noort, Josien C. [1 ,3 ]
Kortier, Henk G. [1 ]
van Beek, Nathalie [2 ]
Veeger, DirkJan H. E. J. [2 ]
Veltink, Peter H. [1 ]
机构
[1] Univ Twente, MIRA Res Inst Biomed Technol & Tech Med, Biomed Signals & Syst Grp, Enschede, Netherlands
[2] Vrije Univ Amsterdam, MOVE Res Inst Amsterdam, Fac Behav & Movement Sci, Dept Human Movement Sci, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, MOVE Res Inst Amsterdam, Dept Rehabil Med, Med Ctr, Amsterdam, Netherlands
来源
PLOS ONE | 2016年 / 11卷 / 11期
关键词
MAGNETIC SENSORS; INDEX FINGER; GLOVE; THUMB; DEFINITIONS; MOVEMENTS;
D O I
10.1371/journal.pone.0164889
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective analysis of hand and finger kinematics is important to increase understanding of hand function and to quantify motor symptoms for clinical diagnosis. The aim of this paper is to compare a new 3D measurement system containing multiple miniature inertial sensors (PowerGlove) with an opto-electronic marker system during specific finger tasks in three healthy subjects. Various finger movements tasks were performed: flexion, fast flexion, tapping, hand open/closing, ab/adduction and circular pointing. 3D joint angles of the index finger joints and position of the thumb and index were compared between systems. Median root mean square differences of the main joint angles of interest ranged between 3.3 and 8.4deg. Largest differences were found in fast and circular pointing tasks, mainly in range of motion. Smallest differences for all 3D joint angles were observed in the flexion tasks. For fast finger tapping, the thumb/index amplitude showed a median difference of 15.8mm. Differences could be explained by skin movement artifacts caused by relative marker movements of the marker system, particularly during fast tasks; large movement accelerations and angular velocities which exceeded the range of the inertial sensors; and by differences in segment calibrations between systems. The PowerGlove is a system that can be of value to measure 3D hand and finger kinematics and positions in an ambulatory setting. The reported differences need to be taken into account when applying the system in studies understanding the hand function and quantifying hand motor symptoms in clinical practice.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Measuring 3D Hand and Finger Kinematics-Comparison between Inertial Sensing and an Opto-Electronic Marker System (vol 11, e0164889, 2016)
    van den Noort, Josien C.
    Kortier, Henk G.
    van Beek, Nathalie
    Veeger, DirkJan H. E. J.
    Veltink, Peter H.
    PLOS ONE, 2018, 13 (02):
  • [2] 3D Heterogeneous Opto-Electronic Integration Technology for System-on-Silicon (SOS)
    Lee, K-W
    Noriki, A.
    Kiyoyama, K.
    Kanno, S.
    Kobayashi, R.
    Jeong, W-C
    Bea, J-C
    Fukushima, T.
    Tanaka, T.
    Koyanagi, M.
    2009 IEEE INTERNATIONAL ELECTRON DEVICES MEETING, 2009, : 495 - 498
  • [3] A novel 3D stacking method for Opto-electronic dies on CMOS ICs
    Duan, Pinxiang
    Raz, Oded.
    Smalbrugge, Barry. E.
    Duis, Jeroen
    Dorren, Harm. J. S.
    OPTICS EXPRESS, 2012, 20 (26): : B386 - B392
  • [4] Hyperspectral Compute-In-Memory Architecture for 3D Opto-Electronic Computing
    Suh, Myoung-Gyun
    2024 IEEE PHOTONICS SOCIETY SUMMER TOPICALS MEETING SERIES, SUM 2024, 2024,
  • [5] Investigation of 3D respiratory motions using IR opto-electronic photogrammetry
    Chu, A
    Yin, F
    Ajlouni, M
    Ryu, S
    Kim, JH
    MEDICAL PHYSICS, 2002, 29 (06) : 1310 - 1310
  • [6] Full 3D opto-electronic simulation tool for nanotextured solar cells
    Michallon, Jerome
    Collin, Stephane
    PHYSICS, SIMULATION, AND PHOTONIC ENGINEERING OF PHOTOVOLTAIC DEVICES VI, 2017, 10099
  • [7] A Novel 3D Stacking Method for Opto-Electronic Dies on CMOS ICs
    Duan, P.
    Raz, O.
    Smalbrugge, B. E.
    Duis, J.
    Dorren, H. J. S.
    2012 38TH EUROPEAN CONFERENCE AND EXHIBITION ON OPTICAL COMMUNICATIONS (ECOC), 2012,
  • [8] Accuracy requirements in opto-electronic 3D measurements. What is enough for the clinic?
    DAmico, M
    RESEARCH INTO SPINAL DEFORMITIES 1, 1997, 37 : 481 - 484
  • [9] Accuracy requirements in opto-electronic 3D measurements. What is enough for the clinic?
    Centro Valutazione Patologie Vertebrali - Riabilitazione S. Stefano, Via Aprutina 194, 62016 P. Potenza Picena , Italy
    不详
    Stud. Health Technol. Informatics, (481-484):
  • [10] 3D Hybrid Integration Technology for Opto-Electronic Hetero-Integrated Systems
    Lee, Kangwook
    Fukushima, Takafumi
    Tanaka, Tetsu
    Koyanagi, Mitsumasa
    PROCESSING, MATERIALS, AND INTEGRATION OF DAMASCENE AND 3D INTERCONNECTS, 2010, 33 (12): : 71 - 90