Measuring 3D Hand and Finger Kinematics-A Comparison between Inertial Sensing and an Opto-Electronic Marker System

被引:19
|
作者
van den Noort, Josien C. [1 ,3 ]
Kortier, Henk G. [1 ]
van Beek, Nathalie [2 ]
Veeger, DirkJan H. E. J. [2 ]
Veltink, Peter H. [1 ]
机构
[1] Univ Twente, MIRA Res Inst Biomed Technol & Tech Med, Biomed Signals & Syst Grp, Enschede, Netherlands
[2] Vrije Univ Amsterdam, MOVE Res Inst Amsterdam, Fac Behav & Movement Sci, Dept Human Movement Sci, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, MOVE Res Inst Amsterdam, Dept Rehabil Med, Med Ctr, Amsterdam, Netherlands
来源
PLOS ONE | 2016年 / 11卷 / 11期
关键词
MAGNETIC SENSORS; INDEX FINGER; GLOVE; THUMB; DEFINITIONS; MOVEMENTS;
D O I
10.1371/journal.pone.0164889
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective analysis of hand and finger kinematics is important to increase understanding of hand function and to quantify motor symptoms for clinical diagnosis. The aim of this paper is to compare a new 3D measurement system containing multiple miniature inertial sensors (PowerGlove) with an opto-electronic marker system during specific finger tasks in three healthy subjects. Various finger movements tasks were performed: flexion, fast flexion, tapping, hand open/closing, ab/adduction and circular pointing. 3D joint angles of the index finger joints and position of the thumb and index were compared between systems. Median root mean square differences of the main joint angles of interest ranged between 3.3 and 8.4deg. Largest differences were found in fast and circular pointing tasks, mainly in range of motion. Smallest differences for all 3D joint angles were observed in the flexion tasks. For fast finger tapping, the thumb/index amplitude showed a median difference of 15.8mm. Differences could be explained by skin movement artifacts caused by relative marker movements of the marker system, particularly during fast tasks; large movement accelerations and angular velocities which exceeded the range of the inertial sensors; and by differences in segment calibrations between systems. The PowerGlove is a system that can be of value to measure 3D hand and finger kinematics and positions in an ambulatory setting. The reported differences need to be taken into account when applying the system in studies understanding the hand function and quantifying hand motor symptoms in clinical practice.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Normative 3D opto-electronic stereo-photogrammetric sagittal alignment parameters in a young healthy adult population
    Kinel, Edyta
    D'Amico, Moreno
    Roncoletta, Piero
    PLOS ONE, 2018, 13 (09):
  • [22] OvMeter: an automated 3D-integrated opto-electronic system for Ostreopsis cf. ovata bloom monitoring
    Francesca Sbrana
    Ettore Landini
    Nikolla Gjeci
    Federica Viti
    Ennio Ottaviani
    Massimo Vassalli
    Journal of Applied Phycology, 2017, 29 : 1363 - 1375
  • [23] OvMeter: an automated 3D-integrated opto-electronic system for Ostreopsis cf. ovata bloom monitoring
    Sbrana, Francesca
    Landini, Ettore
    Gjeci, Nikolla
    Viti, Federica
    Ottaviani, Ennio
    Vassalli, Massimo
    JOURNAL OF APPLIED PHYCOLOGY, 2017, 29 (03) : 1363 - 1375
  • [24] Measuring Fatigue Induced Changes In 3d Trunk Kinematics, Measured By Inertial Magnetic Measurement Units.
    Reenalda, Jasper
    Maartens, Erik
    Noehren, Brian W.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 636 - 636
  • [25] Concurrent Validity Of Inertial Measurement Units With 3D Motion Analysis System For Joint Kinematics
    Balardi, Kathryn
    Johnson, Michael
    Ross, Jaclyn
    Chinworth, Susan
    Vallabhajosula, Srikant
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 130 - 131
  • [26] Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system
    Nuesch, Corina
    Roos, Elena
    Pagenstert, Geert
    Mundermann, Annegret
    JOURNAL OF BIOMECHANICS, 2017, 57 : 32 - 38
  • [27] 3D Silicon Micro-pillars/-walls Decorated with Aluminum-ZnO/ZnO Nanowires for Opto-electronic Device Applications
    Karaagac, Hakan
    Logeeswaran, V. J.
    Islam, M. Saif
    NANOEPITAXY: MATERIALS AND DEVICES IV, 2012, 8467
  • [28] Thermo-mechanical damage analysis of through-hole formation by laser drilling for 3D opto-electronic device assembly
    Yasuda, K
    Kobayashi, M
    Fujimoto, K
    FIFTH INTERNATIONAL SYMPOSIUM ON LASER PRECISION MICROFABRICATION, 2004, 5662 : 621 - 626
  • [29] SIMULATING THE CONTROL OF A SCARA ROBOT BY MEANS OF A 3D HAND POSITION SENSING SYSTEM
    Tarca, Radu
    Moldovan, Ovidiu
    Szabolcs, Csokmai Lehel
    ROBOTICS AND AUTOMATION SYSTEMS, 2010, 166-167 : 433 - +
  • [30] Comparison of two alternative technical marker sets for measuring 3D pelvic motion during gait
    Bruno, Paul
    Barden, John
    JOURNAL OF BIOMECHANICS, 2015, 48 (14) : 3876 - 3882