A fast and sensitive method for the separation of carotenoids using ultra-high performance supercritical fluid chromatography-mass spectrometry

被引:41
|
作者
Jumaah, Firas [1 ]
Plaza, Merichel [1 ]
Abrahamsson, Victor [1 ]
Turner, Charlotta [1 ]
Sandahl, Margareta [1 ]
机构
[1] Lund Univ, Dept Chem, Ctr Anal & Synth, POB 124, S-22100 Lund, Sweden
基金
瑞典研究理事会;
关键词
Carotene; Xanthophyll; Orthogonal column screening; Method development; Supercritical fluid; Mass spectrometry; THIN-LAYER-CHROMATOGRAPHY; LIQUID-CHROMATOGRAPHY; STATIONARY PHASES; BETA-CAROTENE; MAJOR CAROTENOIDS; ALPHA-CAROTENE; CIS ISOMERS; VEGETABLES; FRUITS; FOODS;
D O I
10.1007/s00216-016-9707-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a rapid and sensitive ultra-high performance supercritical fluid chromatography-mass spectrometry (UHPSFC-MS) method has been developed and partially validated for the separation of carotenoids within less than 6 min. Six columns of orthogonal selectivity were examined, and the best separation was obtained by using a 1-aminoanthracene (1-AA) column. The length of polyene chain as well as the number of hydroxyl groups in the structure of the studied carotenoids determines their differences in the physiochemical properties and thus the separation that is achieved on this column. All of the investigated carotenoids were baseline separated with resolution values greater than 1.5. The effects of gradient program, back pressure, and column temperature were studied with respect to chromatographic properties such as retention and selectivity. Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) were compared in both positive and negative mode, using both direct infusion and hyphenated with UHPSFC. The ESI in positive mode provided the highest response. The coefficient of determination (R (2)) for all calibration curves were greater than 0.998. Limit of detection (LOD) was in the range of 2.6 and 25.2 ng/mL for alpha-carotene and astaxanthin, respectively, whereas limit of quantification (LOQ) was in the range of 7.8 and 58.0 ng/mL for alpha-carotene and astaxanthin, respectively. Repeatability and intermediate precision of the developed UHPSFC-MS method were determined and found to be RSD < 3 % and RSD < 6 %, respectively. The method was applied in order to determine carotenoids in supercritical fluid extracts of microalgae and rosehip.
引用
收藏
页码:5883 / 5894
页数:12
相关论文
共 50 条
  • [21] CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY
    WRIGHT, BW
    KALINOSKI, HT
    UDSETH, HR
    SMITH, RD
    [J]. JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (03): : 145 - 153
  • [22] Development and validation of ultra-high performance supercritical fluid chromatography method for determination of illegal dyes and comparison to ultra-high performance liquid chromatography method
    Khalikova, Maria A.
    Satinsky, Dalibor
    Solich, Petr
    Novakova, Lucie
    [J]. ANALYTICA CHIMICA ACTA, 2015, 874 : 84 - 96
  • [23] Separation and characterization of phenylamides from Piper kadsura using preparative supercritical fluid chromatography and ultra-high-performance supercritical fluid chromatography-tandem mass spectrometry
    Dai, Zhuoshun
    Jiang, Dasen
    Dai, Yingping
    Han, Rongrong
    Fu, Qing
    Jin, Yu
    Liang, Xinmiao
    [J]. JOURNAL OF SEPARATION SCIENCE, 2021, 44 (19) : 3530 - 3539
  • [24] Characterization and identification of in vitro metabolites of (-)-epicatechin using ultra-high performance liquid chromatography-mass spectrometry
    Cai, Rui Jun
    Yin, Xiao Ling
    Liu, Jing
    Qin, Da Xu
    Zhao, Gui Zhen
    [J]. TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2017, 16 (12) : 2985 - 2990
  • [25] Development of ultra-high-performance supercritical fluid chromatography-mass spectrometry assays to analyze potential biomarkers in sweat
    Herniman, Julie M.
    Worsley, Peter R.
    Greenhill, Rachel
    Bader, Dan L.
    Langley, G. John
    [J]. JOURNAL OF SEPARATION SCIENCE, 2022, 45 (02) : 542 - 550
  • [26] CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY USING A HIGH MASS QUADRUPOLE AND SPLITLESS INJECTION
    PINKSTON, JD
    OWENS, GD
    BURKES, LJ
    DELANEY, TE
    MILLINGTON, DS
    MALTBY, DA
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (10) : 962 - 966
  • [27] Highly sensitive and accurate profiling of carotenoids by supercritical fluid chromatography coupled with mass spectrometry
    Matsubara, Atsuki
    Bamba, Takeshi
    Ishida, Hiroki
    Fukusaki, Eiichiro
    Hirata, Kazumasa
    [J]. JOURNAL OF SEPARATION SCIENCE, 2009, 32 (09) : 1459 - 1464
  • [28] Separation and detection of aqueous atmospheric aerosol mimics using supercritical fluid chromatography-mass spectrometry
    Grace, Daisy N.
    Sebold, Melissa B.
    Galloway, Melissa M.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (07) : 3841 - 3851
  • [29] An improved method for the separation of carotenoids and carotenoid isomers by liquid chromatography-mass spectrometry
    Li, Shuang
    Tang, Xinyi
    Lu, Yingying
    Xu, Jilin
    Chen, Juanjuan
    Chen, Haimin
    [J]. JOURNAL OF SEPARATION SCIENCE, 2021, 44 (02) : 539 - 548
  • [30] Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the analysis of pharmaceutical compounds
    Perrenoud, Alexandre Grand-Guillaume
    Veuthey, Jean-Luc
    Guillarme, Davy
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1266 : 158 - 167