Endothelial Keratoplasty The Relationship between Donor Tissue Storage Time and Donor Endothelial Survival

被引:35
|
作者
Terry, Mark A. [1 ]
Shamie, Neda [1 ]
Straiko, Michael D. [1 ]
Friend, Daniel J. [2 ]
Davis-Boozer, David [2 ]
机构
[1] Devers Eye Inst, Portland, OR 97210 USA
[2] Oregon Vis Res Lab, Lions Eye Bank, Portland, OR USA
关键词
PRECUT TISSUE; GRAFT FAILURE; DISLOCATION;
D O I
10.1016/j.ophtha.2010.04.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the relationship between storage time in Optisol GS (Bausch & Lomb, St. Louis, MO) and postoperative cell loss after Descemet's stripping automated endothelial keratoplasty (DSAEK) surgery. Design: Retrospective analysis of a noncomparative, interventional case series. Participants: Three hundred sixty-two eyes of 265 patients undergoing DSAEK surgery for Fuchs' endothelial dystrophy. Methods: Storage times (death to surgery) of donor tissue were recorded for 362 eyes undergoing DSAEK surgery. Donor cell loss at 6, 12, and 24 months was recorded. Analysis of storage times with endothelial cell loss was performed using a Pearson correlation coefficient and an independent samples Student t test. Main Outcome Measures: Percentage of donor endothelial cell loss as measured by specular microscopy of central endothelial cell density (ECD). Results: The mean storage time was 98.95 +/- 33 hours (range, 20.65-186.02 hours). The mean percent endothelial cell loss from before to after surgery was 29 +/- 16% at 6 months (n = 362), 31 +/- 16% at 12 months (n = 263), and 32 +/- 20% at 24 months (n = 98). Storage time did not correlate significantly with endothelial cell loss at any postoperative time point (6 months: r = -0.047, P = 0.373; 12 months: r = -0.023, P = 0.709; 24 months: r = -0.14, P = 0.169). The mean cell loss for corneas stored 0 to 4 days (n = 55) was 32 +/- 17% at 2 years and the mean cell loss for corneas stored for more than 4 days (n = 43) was 30 +/- 18% at 2 years (P = 0.57). At the extremes of storage time, 10 corneas stored for the shortest time (1.5 days) had a 1-year cell loss of 33% and 10 corneas stored for the longest time (7 days) had a 1-year cell loss of 30% (P = 0.45). Conclusions: No correlation was found between the characteristic of storage time and the decline of ECD. Surgeons should not make special requests to the eye bank for short storage times with the hope of improving donor endothelial survival. The upper limit of donor storage time as it relates to acceptable postoperative endothelial cell loss is not known.
引用
收藏
页码:36 / 40
页数:5
相关论文
共 50 条
  • [31] Assessing the consistency and quality of pre-cut donor tissue for endothelial keratoplasty
    Koay, Su-yin
    Man Fung, Simon Sheung
    Shah, Khilan
    Theodossiades, Julia Elizabeth
    Shah, Shima
    Shweikh, Yusrah
    Li, Olivia
    Wilkins, Mark R.
    Angunawela, Romesh
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [32] Descemet-stripping Automated Endothelial Keratoplasty Effect of Anterior Lamellar Corneal Tissue-On/-Off Storage Condition on Descemet-stripping Automated Endothelial Keratoplasty Donor Tissue
    Ide, Takeshi
    Yoo, Sonia H.
    Kymionis, George D.
    Goldman, James M.
    Perez, Victor L.
    O'Brien, Terrence P.
    CORNEA, 2008, 27 (07) : 754 - 757
  • [33] Descemet's Stripping Automated Endothelial Keratoplasty: The Tenuous Relationship between Donor Thickness and Postoperative Vision
    Terry, Mark A.
    Straiko, Michael D.
    Goshe, Jeffrey M.
    Li, Jennifer Y.
    Davis-Boozer, David
    OPHTHALMOLOGY, 2012, 119 (10) : 1988 - 1996
  • [34] Donor Descemet membrane detachment after endothelial keratoplasty
    Romaniv, Natalya
    Price, Marianne O.
    Price, Francis W.
    Mamalis, Nick
    CORNEA, 2006, 25 (08) : 943 - 947
  • [35] Endothelial cells loosing in donor cornea after keratoplasty
    Sarnicola, V
    Perrone, A
    Addabbo, G
    Chisci, C
    Tartaglia, B
    Manes, C
    SOE '97 - XI CONGRESS OF THE EUROPEAN SOCIETY OF OPHTHALMOLOGY, VOLS 1 AND 2, 1997, : 1527 - 1529
  • [36] Safety of Donor Tissue Preparation and Use of Descemetoschisis and Torn Tissue in Descemet Membrane Endothelial Keratoplasty
    Heindl, Ludwig M.
    Bucher, Franziska
    Caramoy, Albert
    Hos, Deniz
    Matthaei, Mario
    Cursiefen, Claus
    CORNEA, 2014, 33 (10) : E7 - E9
  • [37] ACTIVITY STANDARD OF DONOR ENDOTHELIAL CELLS IN PENETRATING KERATOPLASTY
    Xie Li-xin
    Kang Feng-ying
    Dong Xiao-guang
    CHINESEMEDICALJOURNAL, 1988, (01)
  • [38] Donor Infection After Endothelial Keratoplasty: Potential Issues
    Jhanji, Vishal
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2012, 1 (04): : 250 - 250
  • [39] Influence of Donor Characteristics on Descemet Membrane Endothelial Keratoplasty
    Heinzelmann, Sonja
    Huether, Silja
    Boehringer, Daniel
    Eberwein, Philipp
    Reinhard, Thomas
    Maier, Philip
    CORNEA, 2014, 33 (06) : 644 - 648
  • [40] Preconditioned Donor Corneal Thickness for Microthin Endothelial Keratoplasty
    Thomas, Peter B. M.
    Mukherjee, Achyut N.
    O'Donovan, Dominic
    Rajan, Madhavan S.
    CORNEA, 2013, 32 (07) : E173 - E178