Endothelial Keratoplasty The Relationship between Donor Tissue Storage Time and Donor Endothelial Survival

被引:35
|
作者
Terry, Mark A. [1 ]
Shamie, Neda [1 ]
Straiko, Michael D. [1 ]
Friend, Daniel J. [2 ]
Davis-Boozer, David [2 ]
机构
[1] Devers Eye Inst, Portland, OR 97210 USA
[2] Oregon Vis Res Lab, Lions Eye Bank, Portland, OR USA
关键词
PRECUT TISSUE; GRAFT FAILURE; DISLOCATION;
D O I
10.1016/j.ophtha.2010.04.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the relationship between storage time in Optisol GS (Bausch & Lomb, St. Louis, MO) and postoperative cell loss after Descemet's stripping automated endothelial keratoplasty (DSAEK) surgery. Design: Retrospective analysis of a noncomparative, interventional case series. Participants: Three hundred sixty-two eyes of 265 patients undergoing DSAEK surgery for Fuchs' endothelial dystrophy. Methods: Storage times (death to surgery) of donor tissue were recorded for 362 eyes undergoing DSAEK surgery. Donor cell loss at 6, 12, and 24 months was recorded. Analysis of storage times with endothelial cell loss was performed using a Pearson correlation coefficient and an independent samples Student t test. Main Outcome Measures: Percentage of donor endothelial cell loss as measured by specular microscopy of central endothelial cell density (ECD). Results: The mean storage time was 98.95 +/- 33 hours (range, 20.65-186.02 hours). The mean percent endothelial cell loss from before to after surgery was 29 +/- 16% at 6 months (n = 362), 31 +/- 16% at 12 months (n = 263), and 32 +/- 20% at 24 months (n = 98). Storage time did not correlate significantly with endothelial cell loss at any postoperative time point (6 months: r = -0.047, P = 0.373; 12 months: r = -0.023, P = 0.709; 24 months: r = -0.14, P = 0.169). The mean cell loss for corneas stored 0 to 4 days (n = 55) was 32 +/- 17% at 2 years and the mean cell loss for corneas stored for more than 4 days (n = 43) was 30 +/- 18% at 2 years (P = 0.57). At the extremes of storage time, 10 corneas stored for the shortest time (1.5 days) had a 1-year cell loss of 33% and 10 corneas stored for the longest time (7 days) had a 1-year cell loss of 30% (P = 0.45). Conclusions: No correlation was found between the characteristic of storage time and the decline of ECD. Surgeons should not make special requests to the eye bank for short storage times with the hope of improving donor endothelial survival. The upper limit of donor storage time as it relates to acceptable postoperative endothelial cell loss is not known.
引用
收藏
页码:36 / 40
页数:5
相关论文
共 50 条
  • [21] ENDOTHELIAL-CELL DENSITIES IN DONOR AND RECIPIENT TISSUE AFTER KERATOPLASTY
    RUUSUVAARA, P
    ACTA OPHTHALMOLOGICA, 1980, 58 (02): : 267 - 277
  • [22] Descemet-stripping automated endothelial keratoplasty with a donor tissue injector
    Khor, Wei-Boon
    Kim, Terry
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (11): : 1768 - 1772
  • [23] Comment on donor tissue preparation for Descemet membrane endothelial keratoplasty REPLY
    Lie, Jessica
    Birbal, Renuka
    Ham, Lisanne
    Dapena, Isabel
    van der Wees, Jacqueline
    Melles, Gerrit R. J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (03): : 408 - 408
  • [24] A Surgical Technique for Donor Tissue Harvesting for Descemet Membrane Endothelial Keratoplasty
    Sikder, Shameema
    Ward, Donald
    Jun, Albert S.
    CORNEA, 2011, 30 (01) : 91 - 94
  • [25] Endothelial keratoplasty - Improvement of vision after healthy donor tissue exchange
    Chen, Edwin S.
    Shamie, Neda
    Terry, Mark A.
    Hoar, Karen L.
    CORNEA, 2008, 27 (03) : 279 - 282
  • [26] Descemet Stripping Automated Endothelial Keratoplasty Using Infant Donor Tissue
    Kim, Peter
    Yeung, Sonia N.
    Lichtinger, Alejandro
    Amiran, Maoz D.
    Rootman, David S.
    CORNEA, 2012, 31 (01) : 52 - 54
  • [27] Impact of donor tissue diameter on postoperative central endothelial cell density in Descemet Membrane Endothelial Keratoplasty
    Schrittenlocher, Silvia
    Bachmann, Bjoern
    Cursiefen, Claus
    ACTA OPHTHALMOLOGICA, 2019, 97 (04) : E618 - E622
  • [28] PENETRATING KERATOPLASTY WITH FRESH AND CRYOPRESERVED CORNEAS - DONOR ENDOTHELIAL CELL SURVIVAL IN PRIMATES
    BOURNE, WM
    ARCHIVES OF OPHTHALMOLOGY, 1978, 96 (06) : 1073 - 1074
  • [29] Younger Donor Tissue in Descemet Membrane Endothelial Keratoplasty Surgery: Clinical Outcomes
    Hill, Jordan R.
    Chen, Shin-Yi
    Bauer, Alex J.
    Straiko, Megan M. W.
    Sanchez, Philip James
    Straiko, Michael D.
    Terry, Mark A.
    CORNEA, 2021, 40 (08) : 1024 - 1030
  • [30] Donor Tissue Culture Conditions and Outcome after Descemet Membrane Endothelial Keratoplasty
    Laaser, Kathrin
    Bachmann, Bjoern O.
    Horn, Folkert K.
    Schloetzer-Schrehardt, Ursula
    Cursiefen, Claus
    Kruse, Friedrich E.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (06) : 1007 - 1018