Comparison of four methods for the estimation of intracranial volume: A gold standard study

被引:53
|
作者
Sahin, B. [1 ]
Acer, N.
Sonmez, O. F.
Emirzeoglu, M.
Basaloglu, H.
Uzun, A.
Bilgic, S.
机构
[1] Ondokuz Mayis Univ, Sch Med, Dept Anat, TR-55139 Samsun, Turkey
[2] Univ Mugla, Allied Hlth Sch, Dept Nursing, Mugla, Turkey
[3] Gazi Govt Hosp, Neurosurg Clin, Samsun, Turkey
[4] Adnan Menderes Univ, Sch Med, Dept Anat, Aydin, Turkey
关键词
intracranial volume; water-filling; cephalometry; point-counting; planimetry; stereology;
D O I
10.1002/ca.20520
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Investigators can infer how much reduction in volume has occurred since brain volume was at its peak, by combining measures of brain volume with measures of intracranial volume (ICV). Several methodologies have been proposed to asses the ICV. However, we have not seen a gold-standard study evaluating the results of the methodologies for the assessment of ICV. In the present study, the actual intracranial volume of 20 dry skulls was measured using the water-filling method, using this as a gold standard. Anthropometry, cephalometry, point-counting, and planimetry techniques were applied to the same skulls to estimate the ICV. Anthropometric and cephalometric measurements were carried out directly on skulls and roentgenograms, respectively. Consecutive computed tomography sections at a thickness of 10 mm were used to estimate the ICV of the skulls by means of the point-counting and planimetry methods. The mean (+/- SD) of the actual ICV measured by the water-filling method was 1,262.0 +/- 160.4 cm(3) (1,389.5 +/- 96.5 cm(3) for males and 1,134.5 +/- 94.3 cm 3 for females, respectively). Our results showed that the estimated values obtained by all four methods differed from the actual volumes of the skulls (P < 0.05). The data obtained by anthropometry resulted in overestimation. However, cephalometry, point-counting, and planimetry methods produced underestimation. After calibration, there were no significant differences between the actual volumes and the results of the four methods (P > 0.05). While the anthropometric method is easy and quick to apply, its result may deviate from the actual values. The optimized stereological techniques of point-counting and planimetry methods may provide unbiased ICV results since they take the third dimension of the structures into account.
引用
收藏
页码:766 / 773
页数:8
相关论文
共 50 条
  • [21] Comparison of methods for thyroid volume estimation in patients with Graves' disease
    van Isselt, JW
    de Klerk, JMH
    van Rijk, PP
    van Gils, APG
    Polman, LJ
    Kamphuis, C
    Meijer, R
    Beekman, FJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) : 525 - 531
  • [22] Comparison of methods for thyroid volume estimation in patients with Graves' disease
    Johannes W. van Isselt
    John M. H. de Klerk
    Peter P. van Rijk
    Adrianus P. G. van Gils
    Lambertus J. Polman
    Chris Kamphuis
    Rudy Meijer
    Freek J. Beekman
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 525 - 531
  • [23] A Comparison of Gradient Estimation Methods for Volume Rendering on Unstructured Meshes
    Correa, Carlos D.
    Hero, Robert
    Ma, Kwan-Liu
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2011, 17 (03) : 305 - 319
  • [24] A comparison study of four SNP selection methods
    Butler, JM
    Bishop, DT
    Barrett, JH
    ANNALS OF HUMAN GENETICS, 2005, 69 : 765 - 766
  • [25] Prospective Study on Noninvasive Assessment of Intracranial Pressure in Traumatic Brain-Injured Patients: Comparison of Four Methods
    Cardim, Danilo
    Robba, Chiara
    Donnelly, Joseph
    Bohdanowicz, Michal
    Schmidt, Bernhard
    Damian, Maxwell
    Varsos, Georgios V.
    Liu, Xiuyun
    Cabeleira, Manuel
    Frigieri, Gustavo
    Cabella, Brenno
    Smielewski, Peter
    Mascarenhas, Sergio
    Czosnyka, Marek
    JOURNAL OF NEUROTRAUMA, 2016, 33 (08) : 792 - 802
  • [26] Comparison of Standard- and Low-Tube Voltage 320-Detector Row Volume CT Angiography in Detection of Intracranial Aneurysms with Digital Subtraction Angiography as Gold Standard
    Sun, Gang
    Ding, Juan
    Lu, Yang
    Li, Min
    Li, Li
    Li, Guo-ying
    Zhang, Xu-ping
    ACADEMIC RADIOLOGY, 2012, 19 (03) : 281 - 288
  • [27] Assessment of the optimum section thickness for the estimation of liver volume using magnetic resonance images: A stereological gold standard study
    Sahin, B
    Ergur, H
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (01) : 96 - 101
  • [28] Comparison of four different techniques to evaluate the elastic properties of phantom in elastography: is there a gold standard?
    Oudry, Jennifer
    Lynch, Ted
    Vappou, Jonathan
    Sandrin, Laurent
    Miette, Veronique
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19): : 5775 - 5793
  • [29] Evaluation and Comparison of Automatic Brain Segmentation Methods Based On the Gold Standard Method
    Zamanpour S.A.
    Ganji Z.
    Bigham B.
    Zemorshidi F.
    Zare H.
    Iranian Journal of Medical Physics, 2023, 20 (04) : 233 - 245
  • [30] Comparison of Two Bayesian Methods in Evaluation of the Absence of the Gold Standard Diagnostic Tests
    Li, Taishun
    Liu, Pei
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019