Comparison of four methods for the estimation of intracranial volume: A gold standard study

被引:53
|
作者
Sahin, B. [1 ]
Acer, N.
Sonmez, O. F.
Emirzeoglu, M.
Basaloglu, H.
Uzun, A.
Bilgic, S.
机构
[1] Ondokuz Mayis Univ, Sch Med, Dept Anat, TR-55139 Samsun, Turkey
[2] Univ Mugla, Allied Hlth Sch, Dept Nursing, Mugla, Turkey
[3] Gazi Govt Hosp, Neurosurg Clin, Samsun, Turkey
[4] Adnan Menderes Univ, Sch Med, Dept Anat, Aydin, Turkey
关键词
intracranial volume; water-filling; cephalometry; point-counting; planimetry; stereology;
D O I
10.1002/ca.20520
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Investigators can infer how much reduction in volume has occurred since brain volume was at its peak, by combining measures of brain volume with measures of intracranial volume (ICV). Several methodologies have been proposed to asses the ICV. However, we have not seen a gold-standard study evaluating the results of the methodologies for the assessment of ICV. In the present study, the actual intracranial volume of 20 dry skulls was measured using the water-filling method, using this as a gold standard. Anthropometry, cephalometry, point-counting, and planimetry techniques were applied to the same skulls to estimate the ICV. Anthropometric and cephalometric measurements were carried out directly on skulls and roentgenograms, respectively. Consecutive computed tomography sections at a thickness of 10 mm were used to estimate the ICV of the skulls by means of the point-counting and planimetry methods. The mean (+/- SD) of the actual ICV measured by the water-filling method was 1,262.0 +/- 160.4 cm(3) (1,389.5 +/- 96.5 cm(3) for males and 1,134.5 +/- 94.3 cm 3 for females, respectively). Our results showed that the estimated values obtained by all four methods differed from the actual volumes of the skulls (P < 0.05). The data obtained by anthropometry resulted in overestimation. However, cephalometry, point-counting, and planimetry methods produced underestimation. After calibration, there were no significant differences between the actual volumes and the results of the four methods (P > 0.05). While the anthropometric method is easy and quick to apply, its result may deviate from the actual values. The optimized stereological techniques of point-counting and planimetry methods may provide unbiased ICV results since they take the third dimension of the structures into account.
引用
收藏
页码:766 / 773
页数:8
相关论文
共 50 条
  • [41] Comparison of three methods for the estimation of the pituitary gland volume using magnetic resonance imaging: a stereological study
    Ertekin, Tolga
    Acer, Niyazi
    Turgut, Ahmet T.
    Aycan, Kenan
    Ozcelik, Ozlem
    Turgut, Mehmet
    PITUITARY, 2011, 14 (01) : 31 - 38
  • [42] Comparison Study on methods of software cost estimation
    Ma Junhai
    Mu Lingling
    2010 2ND INTERNATIONAL CONFERENCE ON E-BUSINESS AND INFORMATION SYSTEM SECURITY (EBISS 2010), 2010, : 194 - 197
  • [43] Comparison of two methods for the estimation of subcortical volume and asymmetry using magnetic resonance imaging: a methodological study
    Ertekin, Tolga
    Acer, Niyazi
    Icer, Semra
    Ilica, Ahmet T.
    SURGICAL AND RADIOLOGIC ANATOMY, 2013, 35 (04) : 301 - 309
  • [44] Comparison of two methods for the estimation of subcortical volume and asymmetry using magnetic resonance imaging: a methodological study
    Tolga Ertekin
    Niyazi Acer
    Semra Içer
    Ahmet T. Ilıca
    Surgical and Radiologic Anatomy, 2013, 35 : 301 - 309
  • [45] Comparison of three methods for the estimation of the pituitary gland volume using magnetic resonance imaging: a stereological study
    Tolga Ertekin
    Niyazi Acer
    Ahmet T. Turgut
    Kenan Aycan
    Özlem Özçelik
    Mehmet Turgut
    Pituitary, 2011, 14 : 31 - 38
  • [46] A questionable gold standard for Hippocampus volume and asymmetry
    Hasan, Khader M.
    NEURORADIOLOGY, 2009, 51 (03) : 201 - 202
  • [47] A questionable gold standard for Hippocampus volume and asymmetry
    Khader M. Hasan
    Neuroradiology, 2009, 51 : 201 - 202
  • [48] Estimation of in vivo noise in clinical CT images: comparison and validation of three different methods against ensemble noise gold-standard
    Ria, Francesco
    Smith, Taylor B.
    Abadi, Ehsan
    Solomon, Justin B.
    Samei, Ehsan
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [49] Bayesian estimation of asthma prevalence, and comparison of exercise and questionnaire diagnostics in the absence of a gold standard
    Demissie, K
    White, N
    Joseph, L
    Ernst, P
    ANNALS OF EPIDEMIOLOGY, 1998, 8 (03) : 201 - 208
  • [50] Comparison of four confirmatory tests for the diagnosis of primary aldosteronism: Bayesian analysis in the absence of a gold standard
    Shen, Hang
    Luo, Wenjin
    Hu, Jinbo
    Yang, Jun
    Song, Ying
    Chen, Xiangjun
    Yang, Yi
    Ma, Linqiang
    Cheng, Qingfeng
    Wang, Zhihong
    Li, Qifu
    Yang, Shumin
    ENDOCRINE, 2024, 85 (03) : 1417 - 1424