摘要
Objectives To evaluate the influence of model-based iterative reconstruction (MBIR) with lung setting and conventional setting on pulmonary emphysema quantification by ultra-low-dose computed tomography (ULDCT) compared with standard-dose CT (SDCT). Methods Forty-five patients who underwent ULDCT (0.18 0.02 mSv) and SDCT (6.66 2.69 mSv) were analyzed in this retrospective study. Images were reconstructed using filtered back projection (FBP) with smooth and sharp kernels and MBIR with conventional and lung settings. Extent of emphysema was evaluated using fully automated software. Correlation between ULDCT and SDCT was assessed by interclass correlation coefficiency (ICC) and Bland-Altman analysis. Results Excellent correlation was seen between MBIR with conventional setting on ULDCT and FBP with smooth kernel on SDCT (ICC, 0.97; bias, -0.31%) and between MBIR with lung setting on ULDCT and FBP with sharp kernel on SDCT (ICC, 0.82; bias, -2.10%). Conclusion Model-based iterative reconstruction improved the agreement between ULDCT and SDCT on emphysema quantification.
引用
收藏
页码:760 / 766
页数:7
相关论文
共 50 条
  • [41] Ultra-low-dose sequential computed tomography for quantitative lung aeration assessment—a translational study
    Ball L.
    Braune A.
    Corradi F.
    Brusasco C.
    Garlaschi A.
    Kiss T.
    Bluth T.
    Simonassi F.
    Bergamaschi A.
    Kotzerke J.
    Schultz M.J.
    de Abreu M.G.
    Pelosi P.
    Intensive Care Medicine Experimental, 5 (1)
  • [42] A comparison of Model-Based Iterative Reconstruction (MBIR) technique with standard Dose Computed Tomography of Thorax in the follow up of lung nodules
    O'Mahony, A. M.
    James, K.
    Chawke, L.
    Moore, N.
    Maher, M. M.
    Kennedy, P.
    Murphy, K. P.
    Khan, K. A. Ali
    Murphy, D.
    Henry, M. T.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2017, 186 : S414 - S415
  • [43] A comparison of Model-Based Iterative Reconstruction (MBIR) technique with standard Dose Computed Tomography of Thorax in the follow up of lung nodules
    O'Mahony, Ann
    James, Karl
    Chawke, Liam
    Moore, Niamh
    Maher, Michael M.
    Murphy, Kevin P.
    Khan, Kashif Ali
    Kennedy, Marcus P.
    Murphy, Desmond
    Henry, Michael T.
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [44] A comparison of Model-Based Iterative Reconstruction (MBIR) technique with standard Dose Computed Tomography of Thorax in the follow up of lung nodules
    O'Mahony, A. M.
    James, K.
    Chawke, L.
    Moore, N.
    Maher, M. M.
    Kennedy, M. P.
    Murphy, K. P.
    Khan, K. A. Ali
    Murphy, D.
    Henry, M. T.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2017, 186 (SUPPL 10) : S414 - S415
  • [45] Detection of Pulmonary Embolism on Computed Tomography Improvement Using a Model-based Iterative Reconstruction Algorithm Compared With Filtered Back Projection and Iterative Reconstruction Algorithms
    Kligerman, Seth
    Lahiji, Kian
    Weihe, Elizabeth
    Lin, Cheng Tin
    Terpenning, Silanath
    Jeudy, Jean
    Frazier, Annie
    Pugatch, Robert
    Galvin, Jeffrey R.
    Mittal, Deepika
    Kothari, Kunal
    White, Charles S.
    JOURNAL OF THORACIC IMAGING, 2015, 30 (01) : 60 - 68
  • [46] Emphysema quantification using hybrid versus model-based generations of iterative reconstruction SAFIRE versus ADMIRE
    Martin, Steve P.
    Gariani, Joanna
    Feutry, Gregoire
    Adler, Dan
    Karenovics, Wolfram
    Becker, Christoph D.
    Montet, Xavier
    MEDICINE, 2019, 98 (07)
  • [47] Application of a full model-based iterative reconstruction (MBIR) in 80 kVp ultra-low-dose paranasal sinus CT imaging of pediatric patients
    Jihang Sun
    Qifeng Zhang
    Xiaomin Duan
    Chengyue Zhang
    Pengpeng Wang
    Chenguang Jia
    Yong Liu
    Yun Peng
    La radiologia medica, 2018, 123 : 117 - 124
  • [48] QUANTIFICATION OF EMPHYSEMA USING LOW-DOSE CHEST CT: EFFECT OF ITERATIVE RECONSTRUCTION
    Park, K. J.
    Cho, J. Y.
    RESPIRATORY MEDICINE, 2017, 132 : 274 - 274
  • [49] Application of a full model-based iterative reconstruction (MBIR) in 80 kVp ultra-low-dose paranasal sinus CT imaging of pediatric patients
    Sun, Jihang
    Zhang, Qifeng
    Duan, Xiaomin
    Zhang, Chengyue
    Wang, Pengpeng
    Jia, Chenguang
    Liu, Yong
    Peng, Yun
    RADIOLOGIA MEDICA, 2018, 123 (02): : 117 - 124
  • [50] EVALUATION OF MODEL-BASED ITERATIVE RECONSTRUCTION IN ABDOMINAL COMPUTED TOMOGRAPHY IMAGING AT TWO DIFFERENT DOSE LEVELS
    Hettinger, E.
    Aurumskjold, M-L
    Sartor, H.
    Holmquist, F.
    Svard, D.
    Timberg, P.
    RADIATION PROTECTION DOSIMETRY, 2021, 195 (3-4) : 205 - 211