Pulmonary Emphysema Quantification on Ultra-Low-Dose Computed Tomography Using Model-Based Iterative Reconstruction With or Without Lung Setting

被引:5
|
作者
Hata, Akinori [1 ]
Yanagawa, Masahiro [1 ]
Kikuchi, Noriko [1 ]
Honda, Osamu [1 ]
Tomiyama, Noriyuki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Diagnost & Intervent Radiol, Suita, Osaka, Japan
关键词
computed tomography; pulmonary emphysema; computer-assisted image analysis; radiation dosage; image reconstruction; HIGH-RESOLUTION CT; IMAGE-QUALITY; DENSITOMETRY; MBIR; PHANTOM; MORPHOMETRY; ALGORITHM; AGREEMENT; DISEASE;
D O I
10.1097/RCT.0000000000000755
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate the influence of model-based iterative reconstruction (MBIR) with lung setting and conventional setting on pulmonary emphysema quantification by ultra-low-dose computed tomography (ULDCT) compared with standard-dose CT (SDCT). Methods Forty-five patients who underwent ULDCT (0.18 0.02 mSv) and SDCT (6.66 2.69 mSv) were analyzed in this retrospective study. Images were reconstructed using filtered back projection (FBP) with smooth and sharp kernels and MBIR with conventional and lung settings. Extent of emphysema was evaluated using fully automated software. Correlation between ULDCT and SDCT was assessed by interclass correlation coefficiency (ICC) and Bland-Altman analysis. Results Excellent correlation was seen between MBIR with conventional setting on ULDCT and FBP with smooth kernel on SDCT (ICC, 0.97; bias, -0.31%) and between MBIR with lung setting on ULDCT and FBP with sharp kernel on SDCT (ICC, 0.82; bias, -2.10%). Conclusion Model-based iterative reconstruction improved the agreement between ULDCT and SDCT on emphysema quantification.
引用
收藏
页码:760 / 766
页数:7
相关论文
共 50 条
  • [31] Pulmonary Nodule Volumetry at Different Low Computed Tomography Radiation Dose Levels With Hybrid and Model-Based Iterative Reconstruction: A Within Patient Analysis
    den Harder, Annemarie M.
    Willemink, Martin J.
    van Hamersvelt, Robbert W.
    Vonken, Evertjan P. A.
    Schilham, Arnold M. R.
    Lammers, Jan-Willem J.
    Luijk, Bart
    Budde, Ricardo P. J.
    Leiner, Tim
    de Jong, Pim A.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (04) : 578 - 583
  • [32] Impact of Model-Based Iterative Reconstruction on the Correlation between Computed Tomography Quantification of a Low Lung Attenuation Area and Airway Measurements and Pulmonary Function Test Results in Normal Subjects
    Kim, Da Jung
    Kim, Cherry
    Shin, Chol
    Lee, Seung Ku
    Ko, Chang Sub
    Lee, Ki Yeol
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (06) : 1187 - 1195
  • [33] Ultra-low-dose CT with model-based iterative reconstruction (MBIR): detection of ground-glass nodules in an anthropomorphic phantom study
    Cristiano Rampinelli
    Daniela Origgi
    Vittoria Vecchi
    Luigi Funicelli
    Sara Raimondi
    Paul Deak
    Massimo Bellomi
    La radiologia medica, 2015, 120 : 611 - 617
  • [34] Ultra-low-dose CT with model-based iterative reconstruction (MBIR): detection of ground-glass nodules in an anthropomorphic phantom study
    Rampinelli, Cristiano
    Origgi, Daniela
    Vecchi, Vittoria
    Funicelli, Luigi
    Raimondi, Sara
    Deak, Paul
    Bellomi, Massimo
    RADIOLOGIA MEDICA, 2015, 120 (07): : 611 - 617
  • [35] ULTRA-LOW-DOSE 70-KV CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY USING DUALSOURCE COMPUTED TOMOGRAPHY
    Komatsu, Sei
    Takahashi, Satoru
    Takewa, Mitsuhiko
    Ohara, Tomoki
    Yutani, Chikao
    Kodama, Kazuhisa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1468 - 1468
  • [36] Ultra-low-dose spectral-detector computed tomography for the accurate quantification of pulmonary nodules: an anthropomorphic chest phantom study
    Zhou, Xiuxiu
    Zhang, Hanxiao
    Jin, Xiaoxing
    Zhang, Xiaohui
    Lu, Xiaomei
    Han, Qun
    Xiong, Xiaoge
    Liu, Tian
    Feng, Yan
    Tu, Wenting
    Zhou, Taohu
    Ge, Yanming
    Dong, Peng
    Liu, Shiyuan
    Fan, Li
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (05): : 691 - 703
  • [37] On the Simulation of Ultra-Sparse-View and Ultra-Low-Dose Computed Tomography with Maximum a Posteriori Reconstruction Using a Progressive Flow-Based Deep Generative Model
    Shibata, Hisaichi
    Hanaoka, Shouhei
    Nomura, Yukihiro
    Nakao, Takahiro
    Takenaga, Tomomi
    Hayashi, Naoto
    Abe, Osamu
    TOMOGRAPHY, 2022, 8 (05) : 2129 - 2152
  • [38] The role of ultra-low-dose computed tomography in the detection of pulmonary pathologies: a prospective observational study
    Gobi, K.
    Arunachalam, Venkatesh Kasi
    Varatharajaperumal, Rajesh Kumar
    Cherian, Mathew
    Periaswamy, Gopinath
    Rajesh, S.
    POLISH JOURNAL OF RADIOLOGY, 2022, 87 : 597 - 605
  • [39] Effect of Model-Based Iterative Reconstruction in Chest Computed Tomography on Lymphangioleiomyomatosis (LAM) Cyst Score Quantification
    Hu-Wang, E.
    Schuzer, J. L.
    Rollison, S.
    Gopalakrishnan, V.
    Machado, T.
    Jones, A.
    Julien-Williams, P.
    Moss, J.
    Chen, M. Y.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [40] Ultra-low-dose lung multidetector computed tomography in children-Approaching 0.2 millisievert
    Tschauner, Sebastian
    Zellner, Michael
    Pistorius, Sarah
    Gnannt, Ralph
    Schraner, Thomas
    Kellenberger, Christian J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 139