The role of ultra-low-dose computed tomography in the detection of pulmonary pathologies: a prospective observational study

被引:3
|
作者
Gobi, K. [1 ]
Arunachalam, Venkatesh Kasi [1 ]
Varatharajaperumal, Rajesh Kumar [1 ]
Cherian, Mathew [1 ]
Periaswamy, Gopinath [1 ]
Rajesh, S. [1 ]
机构
[1] Kovai Med Ctr & Hosp, Coimbatore, India
关键词
ultra-low-dose CT; pulmonary nodules; radiation dose; third generation; dual source; dual energy; DUAL-SOURCE CT; ITERATIVE RECONSTRUCTION; IMAGE QUALITY; CHEST CT; NODULE DETECTION; PERFORMANCE; PROTOCOLS; SCANNER;
D O I
10.5114/pjr.2022.121433
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of the study was to compare the image noise, radiation dose, and image quality of ultra-low-dose computed tomography (CT) and standard CT in the imaging of pulmonary pathologies.Material and methods: This observational study was performed between July 2020 and August 2021. All enrolled patients underwent both ultra-low-dose and standard CTs. The image noise, image quality for normal pulmonary structures, presence or absence of various pulmonary lesions, and radiation dose were recorded for each of the scans. The findings of standard-dose CT were regarded as the gold standard and compared with that of ultra-low-dose CT. Results: A total of 124 patients were included in the study. The image noise was higher in the ultra-low-dose CT compared to standard-dose CT. The overall image quality was determined to be diagnostic in 100% of standard CT images and in 96.77% of ultra-low-dose CT images with proportional worsening of the image quality as the body mass index (BMI) range was increased. Ultra-low-dose CT offered higher (> 90%) sensitivity for lesions like consoli-dation (97%), pleural effusion (95%), fibrosis (92%), and solid pulmonary nodules (91%). The effective radiation dose (mSv) was many times lower in ultra-low-dose CT when compared to standard-dose CT (mean +/- SD: 0.50 +/- 0.005 vs. 3.99 +/- 1.57).Conclusions: The radiation dose of ultra-low-dose chest CT was almost equal to that of a chest X-ray. It could be used for the screening and/or follow-up of patients with solid pulmonary nodules (> 3 mm) and consolidation.
引用
收藏
页码:597 / 605
页数:9
相关论文
共 50 条
  • [1] Detection of pulmonary nodules with scoutless fixed-dose ultra-low-dose CT: a prospective study
    Gerald Gheysens
    Walter De Wever
    Lesley Cockmartin
    Hilde Bosmans
    Walter Coudyzer
    Sofie De Vuysere
    Mathieu Lefere
    [J]. European Radiology, 2022, 32 : 4437 - 4445
  • [2] Detection of pulmonary nodules with scoutless fixed-dose ultra-low-dose CT: a prospective study
    Gheysens, Gerald
    De Wever, Walter
    Cockmartin, Lesley
    Bosmans, Hilde
    Coudyzer, Walter
    De Vuysere, Sofie
    Lefere, Mathieu
    [J]. EUROPEAN RADIOLOGY, 2022, 32 (07) : 4437 - 4445
  • [3] Ultra-low-dose Computed Tomography in Management of Pulmonary Abscess Caused by Cystic Fibrosis
    Nandurkar, R.
    Lau, K. K.
    [J]. HONG KONG JOURNAL OF RADIOLOGY, 2018, 21 (04): : 271 - 273
  • [4] Ultra-low-dose chest computed tomography without anesthesia in the assessment of pediatric pulmonary diseases
    Dorneles, Cristina Manera
    Pacini, Gabriel Sartori
    Zanon, Matheus
    Altmayer, Stephan
    Watte, Guilherme
    Barros, Marcelo C.
    Marchiori, Edson
    Baldisserotto, Matteo
    Hochhegger, Bruno
    [J]. JORNAL DE PEDIATRIA, 2020, 96 (01) : 92 - 99
  • [5] softMip: A novel projection algorithm for ultra-low-dose computed tomography
    Meyer, Henning
    Juran, Ralf
    Rogalla, Patrik
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (03) : 480 - 484
  • [6] Ultra-low-dose sequential computed tomography for quantitative lung aeration assessment—a translational study
    Ball L.
    Braune A.
    Corradi F.
    Brusasco C.
    Garlaschi A.
    Kiss T.
    Bluth T.
    Simonassi F.
    Bergamaschi A.
    Kotzerke J.
    Schultz M.J.
    de Abreu M.G.
    Pelosi P.
    [J]. Intensive Care Medicine Experimental, 5 (1)
  • [7] Diagnostic accuracy of ultra-low-dose chest computed tomography in an emergency department
    Taekker, Maria
    Kristjansdottir, Bjorg
    Andersen, Michael B.
    Fransen, Maja L.
    Greisen, Pernille W.
    Laursen, Christian B.
    Mussmann, Bo
    Posth, Stefan
    Graumann, Ole
    [J]. ACTA RADIOLOGICA, 2022, 63 (03) : 336 - 344
  • [8] The Emergence of Ultra-Low-Dose Computed Tomography and the Impending Obsolescence of the Plain Radiograph?
    McLaughlin, Patrick D.
    Ouellette, Hugue A.
    Louis, Luck J.
    Mallinson, Paul I.
    O'Connell, Timothy
    Mayo, John R.
    Munk, Peter L.
    Nicolaou, Savvas
    [J]. CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (04): : 314 - 318
  • [9] Ultra-low-dose spectral-detector computed tomography for the accurate quantification of pulmonary nodules: an anthropomorphic chest phantom study
    Zhou, Xiuxiu
    Zhang, Hanxiao
    Jin, Xiaoxing
    Zhang, Xiaohui
    Lu, Xiaomei
    Han, Qun
    Xiong, Xiaoge
    Liu, Tian
    Feng, Yan
    Tu, Wenting
    Zhou, Taohu
    Ge, Yanming
    Dong, Peng
    Liu, Shiyuan
    Fan, Li
    [J]. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (05): : 691 - 703
  • [10] ULTRA-LOW-DOSE 70-KV CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY USING DUALSOURCE COMPUTED TOMOGRAPHY
    Komatsu, Sei
    Takahashi, Satoru
    Takewa, Mitsuhiko
    Ohara, Tomoki
    Yutani, Chikao
    Kodama, Kazuhisa
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1468 - 1468