Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia

被引:67
|
作者
Lourenco, Pedro D. M. [1 ]
Rawski, Ryan [2 ]
Mohammed, Mohammed F. [1 ,3 ]
Khosa, Faisal [1 ]
Nicolaou, Savvas [1 ]
McLaughlin, Patrick [1 ]
机构
[1] Univ British Columbia, Vancouver Gen Hosp, Dept Radiol, 3350-950 W 10th Ave, Vancouver, BC V5Z 1M9, Canada
[2] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[3] King Saud bin Abdulaziz Univ Hlth Sci, Abdominal Imaging Sect, Med Imaging Dept, King Abdullah Int Med Res Ctr,Minist Natl Guard,H, Riyadh, Saudi Arabia
关键词
acute intestinal ischemia; bowel ischemia; dual-energy CT; iodine mapping; virtual monoenergetic; ACUTE MESENTERIC ISCHEMIA; MDCT; MANAGEMENT;
D O I
10.2214/AJR.18.19554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Sensitivity of CT of the abdomen for detection of acute bowel ischemia (ABI) can be as low as 60%. In this study, we assessed the diagnostic performance of iodinemap and monoenergetic (40-keV) images in patients with suspected ABI. MATERIALS AND METHODS. This retrospective study included 60 consecutive patients with suspected ABI who underwent a standardized imaging protocol dual-source dualenergy CT (DECT) over a 26-month period. Clinical and operative outcomes were recorded as the reference standard. Two abdominal radiologists who were unaware of clinical and surgical information independently assessed conventional CT images for ABI. After a time interval designed to reduce recall, readers reassessed conventional images with supplementary iodine-map and 40-keV postprocessed images. Quantitative ROI analysis was also performed. RESULTS. ABI was observed in 11 patients. For reader A, sensitivity was 63.6% (95% CI, 30.8-89.1%) when interpreting conventional images alone. Sensitivity for detection of ABI increased to 81.8% (95% CI, 48.2-97.7%) and 100% (95% CI, 71.5-100%) when iodine-map and 40-keV images were assessed, respectively. For reader B, no change in sensitivity was seen with either technique, but the number of false-positives were reduced with supplementary iodinemap and 40-keV postprocessed images. Interobserver agreement was fair with conventional images (lc = 0.29) but improved to moderate (x = 0.45) and substantial (x = 0.63) with iodinemap and 40-keV images, respectively. Quantitative assessment found significant differences in iodine uptake (1.01 +/- 0.55 mg/mL vs 3.04 +/- 1.19 mg/mL) and mean attenuation (75.2 +/- 38.4 HU vs 163.5 +/- 48.9 HU) between nonischemic and ischemic segments, respectively. CONCLUSION. Iodine-map and 40-keV monoenergetic images increase conspicuity of ABI, resulting in improved diagnostic accuracy compared with review of conventional CT images alone.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 50 条
  • [41] Dual-energy CT in early acute pancreatitis: improved detection using iodine quantification
    Simon S. Martin
    Franziska Trapp
    Julian L. Wichmann
    Moritz H. Albrecht
    Lukas Lenga
    James Durden
    Christian Booz
    Thomas J. Vogl
    Tommaso D’Angelo
    [J]. European Radiology, 2019, 29 : 2226 - 2232
  • [42] Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn’s disease
    Sang Min Lee
    Se Hyung Kim
    Su Joa Ahn
    Hyo-Jin Kang
    Ji Hee Kang
    Joon Koo Han
    [J]. European Radiology, 2018, 28 : 2525 - 2534
  • [43] Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
    Hongwei Liang
    Yang Zhou
    Qiao Zheng
    Gaowu Yan
    Hongfan Liao
    Silin Du
    Xiaohui Zhang
    Fajin Lv
    Zhiwei Zhang
    Yong-mei Li
    [J]. Insights into Imaging, 13
  • [44] Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn's disease
    Lee, Sang Min
    Kim, Se Hyung
    Ahn, Su Joa
    Kang, Hyo-Jin
    Kang, Ji Hee
    Han, Joon Koo
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (06) : 2525 - 2534
  • [45] Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging
    Sudarski, Sonja
    Apfaltrer, Paul
    Nance, John W., Jr.
    Schneider, David
    Meyer, Mathias
    Schoenberg, Stefan O.
    Fink, Christian
    Henzler, Thomas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (10) : E574 - E581
  • [46] Advantages and disadvantages of single-source dual-energy whole-body CT angiography with 50% reduced iodine dose at 40 keV reconstruction
    Noda, Yoshifumi
    Nakamura, Fumihiko
    Yasuda, Noriyuki
    Miyoshi, Toshiharu
    Kawai, Nobuyuki
    Kawada, Hiroshi
    Hyodo, Fuminori
    Matsuo, Masayuki
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1121):
  • [47] Value of low-keV virtual monoenergetic plus dual-energy computed tomographic imaging for detection of acute pulmonary embolism
    Wannasopha, Yutthaphan
    Leesmidt, Kantheera
    Srisuwan, Tanop
    Euathrongchit, Juntima
    Tantraworasin, Apichat
    [J]. PLOS ONE, 2022, 17 (11):
  • [48] Evaluation of optimal monoenergetic images acquired by dual-energy CT in the diagnosis of T staging of thoracic esophageal cancer
    Fanrong Cheng
    Yan Liu
    Lihong Du
    Lei Wang
    Lan Li
    Jinfang Shi
    Xiaoxia Wang
    Jiuquan Zhang
    [J]. Insights into Imaging, 14
  • [49] Evaluation of optimal monoenergetic images acquired by dual-energy CT in the diagnosis of T staging of thoracic esophageal cancer
    Cheng, Fanrong
    Liu, Yan
    Du, Lihong
    Wang, Lei
    Li, Lan
    Shi, Jinfang
    Wang, Xiaoxia
    Zhang, Jiuquan
    [J]. INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [50] Applications of dual-energy CT in acute musculoskeletal and trauma imaging-a review
    Singla, Nehal
    Joshi, Madhuvanti
    Amerasekera, Steve
    Choudhary, Surabhi
    [J]. SKELETAL RADIOLOGY, 2024, 53 (11) : 2333 - 2345