Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn's disease

被引:47
|
作者
Lee, Sang Min [1 ]
Kim, Se Hyung [2 ,3 ]
Ahn, Su Joa [2 ,3 ]
Kang, Hyo-Jin [2 ,3 ]
Kang, Ji Hee [2 ]
Han, Joon Koo [2 ,3 ,4 ]
机构
[1] Hallym Univ, Dept Radiol, Sacred Heart Hosp, Anyang, South Korea
[2] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehangno, Seoul 03080, South Korea
[3] Seoul Natl Univ, Coll Med, Dept Radiol, 101 Daehangno, Seoul 03080, South Korea
[4] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Small bowel; Crohn's disease; Diagnostic performance; Dual-energy CT enterography; Spectral CT; STATISTICAL ITERATIVE RECONSTRUCTION; MAGNETIC-RESONANCE ENTEROGRAPHY; TOMOGRAPHY ENTEROGRAPHY; IMAGE QUALITY; ABDOMEN; ENTEROCLYSIS; KVP;
D O I
10.1007/s00330-017-5215-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine the optimal keV on dual-layer, dual-energy CT enterography (dlDE-CTE) and to investigate the added value of virtual monoenergetic images (VMIs) for the diagnosis of active Crohn's disease (CD). We collected 76 patients (including 45 CD patients) who underwent dlDE-CTE. CD was diagnosed using ileocolonoscopy. Conventional polychromatic images (PCI) were reconstructed using an iterative reconstruction algorithm at 120 kVp, and VMI at 40 keV (VMI40), 55 keV (VMI55), and 70 keV (VMI70). Contrast-to-noise ratio (CNR) was compared using Kruskal-Wallis test. Three radiologists independently reviewed PCI and subsequently combined PCI and the optimized VMI for the diagnosis of active CD using a 5-point scale. Multi-reader multi-case receiver operating characteristic analysis was performed. Mean +/- standard deviation of CNRs for both normal (13.6 +/- 6.5, 6.1 +/- 3.2, 2.0 +/- 2.1, 1.9 +/- 1.6; P < 0.001) and abnormal (9.4 +/- 7.3, 6.5 +/- 4.8, 4.9 +/- 3.1, 3.7 +/- 2.3; P < 0.001) bowels were significantly greatest on VMI40, followed by VMI55, VMI70, and PCI. When VMI40 were added to PCI, overall area-under-the-curve of the three radiologists was significantly improved from 0.891 to 0.951 for diagnosing active CD (P=0.009). The lowest monoenergetic images (VMI40) provided the best CNR on dlDE-CTE. Furthermore, the diagnostic performance for diagnosing active CD can be significantly improved with the addition of VMI40. aEuro cent CNR for both normal and abnormal bowel walls is greatest on VMI (40) . aEuro cent Subjective image quality on VMI (40) is better than those on PCI. aEuro cent When VMI (40) images are added to PCI, radiologists' diagnostic performance can be improved.
引用
收藏
页码:2525 / 2534
页数:10
相关论文
共 50 条
  • [1] Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn’s disease
    Sang Min Lee
    Se Hyung Kim
    Su Joa Ahn
    Hyo-Jin Kang
    Ji Hee Kang
    Joon Koo Han
    [J]. European Radiology, 2018, 28 : 2525 - 2534
  • [2] Value of the virtual monoenergetic image from dual-layer dual-energy computed tomography enterography in the preoperative assessment of the internal penetrating complication of Crohn's disease
    Gong, Meilin
    Liu, Lili
    Ren, Huanhuan
    He, Peipei
    Ran, Xiong
    Xu, Yu
    Zou, Ya
    Wu, Jingsong
    Li, Zan
    Tan, Wei
    Zhang, Zhengying
    Li, Kang
    [J]. ABDOMINAL RADIOLOGY, 2024, 49 (03) : 814 - 822
  • [3] Value of the virtual monoenergetic image from dual-layer dual-energy computed tomography enterography in the preoperative assessment of the internal penetrating complication of Crohn’s disease
    Meilin Gong
    Lili Liu
    Huanhuan Ren
    Peipei He
    Xiong Ran
    Yu Xu
    Ya Zou
    Jingsong Wu
    Zan Li
    Wei Tan
    Zhengying Zhang
    Kang Li
    [J]. Abdominal Radiology, 2024, 49 : 814 - 822
  • [4] Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
    Arico, Francesco Marcello
    Trimarchi, Renato
    Portaluri, Antonio
    Barilla, Claudia
    Migliaccio, Nicola
    Bucolo, Giuseppe Mauro
    Cicero, Giuseppe
    Sofia, Carmelo
    Booz, Christian
    Vogl, Thomas J. J.
    Marino, Maria Adele
    Ascenti, Velio
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Ascenti, Giorgio
    [J]. RADIOLOGIA MEDICA, 2023, 128 (08): : 891 - 899
  • [5] Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
    Francesco Marcello Arico’
    Renato Trimarchi
    Antonio Portaluri
    Claudia Barilla’
    Nicola Migliaccio
    Giuseppe Mauro Bucolo
    Giuseppe Cicero
    Carmelo Sofia
    Christian Booz
    Thomas J. Vogl
    Maria Adele Marino
    Velio Ascenti
    Tommaso D’Angelo
    Silvio Mazziotti
    Giorgio Ascenti
    [J]. La radiologia medica, 2023, 128 : 891 - 899
  • [6] Dual-energy CT enterography in evaluation of Crohn’s disease: the role of virtual monochromatic images
    Ezgi Guler
    Nalan Gulsen Unal
    Ilhan Hekimsoy
    Timur Kose
    Mustafa Harman
    Ahmet Omer Ozutemiz
    Nevra Zehra Elmas
    [J]. Japanese Journal of Radiology, 2021, 39 : 341 - 348
  • [7] Dual-energy CT enterography in evaluation of Crohn's disease: the role of virtual monochromatic images
    Guler, Ezgi
    Unal, Nalan Gulsen
    Hekimsoy, Ilhan
    Kose, Timur
    Harman, Mustafa
    Ozutemiz, Ahmet Omer
    Elmas, Nevra Zehra
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2021, 39 (04) : 341 - 348
  • [8] Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging
    Sudarski, Sonja
    Apfaltrer, Paul
    Nance, John W., Jr.
    Schneider, David
    Meyer, Mathias
    Schoenberg, Stefan O.
    Fink, Christian
    Henzler, Thomas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (10) : E574 - E581
  • [9] Value of dual-energy CT enterography in the analysis of pathological bowel segments in patients with Crohn's disease
    Villanueva Campos, A. M.
    Tardaguila de la Fuente, G.
    Utrera Perez, E.
    Jurado Basildo, C.
    Mera Fernandez, D.
    Martinez Rodriguez, C.
    [J]. RADIOLOGIA, 2018, 60 (03): : 223 - 229
  • [10] Prediction of pathological activity in Crohn's disease based on dual-energy CT enterography
    Zhou, Hai-fei
    Chen, Wei
    Li, Jing-qi
    Bai, Gen-ji
    Guo, Li-li
    [J]. ABDOMINAL RADIOLOGY, 2024, 49 (06) : 1829 - 1838