Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia

被引:67
|
作者
Lourenco, Pedro D. M. [1 ]
Rawski, Ryan [2 ]
Mohammed, Mohammed F. [1 ,3 ]
Khosa, Faisal [1 ]
Nicolaou, Savvas [1 ]
McLaughlin, Patrick [1 ]
机构
[1] Univ British Columbia, Vancouver Gen Hosp, Dept Radiol, 3350-950 W 10th Ave, Vancouver, BC V5Z 1M9, Canada
[2] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[3] King Saud bin Abdulaziz Univ Hlth Sci, Abdominal Imaging Sect, Med Imaging Dept, King Abdullah Int Med Res Ctr,Minist Natl Guard,H, Riyadh, Saudi Arabia
关键词
acute intestinal ischemia; bowel ischemia; dual-energy CT; iodine mapping; virtual monoenergetic; ACUTE MESENTERIC ISCHEMIA; MDCT; MANAGEMENT;
D O I
10.2214/AJR.18.19554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Sensitivity of CT of the abdomen for detection of acute bowel ischemia (ABI) can be as low as 60%. In this study, we assessed the diagnostic performance of iodinemap and monoenergetic (40-keV) images in patients with suspected ABI. MATERIALS AND METHODS. This retrospective study included 60 consecutive patients with suspected ABI who underwent a standardized imaging protocol dual-source dualenergy CT (DECT) over a 26-month period. Clinical and operative outcomes were recorded as the reference standard. Two abdominal radiologists who were unaware of clinical and surgical information independently assessed conventional CT images for ABI. After a time interval designed to reduce recall, readers reassessed conventional images with supplementary iodine-map and 40-keV postprocessed images. Quantitative ROI analysis was also performed. RESULTS. ABI was observed in 11 patients. For reader A, sensitivity was 63.6% (95% CI, 30.8-89.1%) when interpreting conventional images alone. Sensitivity for detection of ABI increased to 81.8% (95% CI, 48.2-97.7%) and 100% (95% CI, 71.5-100%) when iodine-map and 40-keV images were assessed, respectively. For reader B, no change in sensitivity was seen with either technique, but the number of false-positives were reduced with supplementary iodinemap and 40-keV postprocessed images. Interobserver agreement was fair with conventional images (lc = 0.29) but improved to moderate (x = 0.45) and substantial (x = 0.63) with iodinemap and 40-keV images, respectively. Quantitative assessment found significant differences in iodine uptake (1.01 +/- 0.55 mg/mL vs 3.04 +/- 1.19 mg/mL) and mean attenuation (75.2 +/- 38.4 HU vs 163.5 +/- 48.9 HU) between nonischemic and ischemic segments, respectively. CONCLUSION. Iodine-map and 40-keV monoenergetic images increase conspicuity of ABI, resulting in improved diagnostic accuracy compared with review of conventional CT images alone.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 50 条
  • [31] Accuracy of 190-keV Virtual Monoenergetic Dual-Energy CT for Determining the Presence or Absence of Intravitreal Silicone Oil
    Bunch, Paul M.
    Lack, Christopher M.
    West, Thomas G.
    Tan, Josh
    Sachs, Jeffrey R.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 216 (04) : 1040 - 1045
  • [32] Quantitative and qualitative assessments of deep learning image reconstruction in low-keV virtual monoenergetic dual-energy CT
    Xu, Jack Junchi
    Lonn, Lars
    Budtz-Jorgensen, Esben
    Hansen, Kristoffer L.
    Ulriksen, Peter S.
    [J]. EUROPEAN RADIOLOGY, 2022, 32 (10) : 7098 - 7107
  • [33] Virtual monoenergetic dual-energy CT reconstructions at 80 keV are optimal non-contrast CT technique for early stroke detection
    Dodig, Doris
    Kastelan, Zrinka Matana
    Bartolovic, Nina
    Jurkovic, Slaven
    Miletic, Damir
    Rumboldt, Zoran
    [J]. NEURORADIOLOGY JOURNAL, 2022, 35 (03): : 337 - 345
  • [34] Virtual monoenergetic reconstruction of contrast-enhanced dual energy CT at 70 keV maximizes mural enhancement in acute small bowel obstruction
    Darras, Kathryn E.
    McLaughlin, Patrick D.
    Kang, Heejun
    Black, Brian
    Walshe, Triona
    Chang, Silvia D.
    Harris, Alison C.
    Nicolaou, Savvas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) : 950 - 956
  • [35] Influence of beam hardening in dual-energy CT imaging: phantom study for iodine mapping, virtual monoenergetic imaging, and virtual non-contrast imaging
    Risa Kanatani
    Takashi Shirasaka
    Tsukasa Kojima
    Toyoyuki Kato
    Masateru Kawakubo
    [J]. European Radiology Experimental, 5
  • [36] Influence of beam hardening in dual-energy CT imaging: phantom study for iodine mapping, virtual monoenergetic imaging, and virtual non-contrast imaging
    Kanatani, Risa
    Shirasaka, Takashi
    Kojima, Tsukasa
    Kato, Toyoyuki
    Kawakubo, Masateru
    [J]. EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
  • [37] Radiation and iodine dose reduced thoraco-abdomino-pelvic dual-energy CT at 40 keV reconstructed with deep learning image reconstruction
    Noda, Yoshifumi
    Kawai, Nobuyuki
    Kawamura, Tomotaka
    Kobori, Akikazu
    Miyase, Rena
    Iwashima, Ken
    Kaga, Tetsuro
    Miyoshi, Toshiharu
    Hyodo, Fuminori
    Kato, Hiroki
    Matsuo, Masayuki
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1134):
  • [38] Dual-energy (MV/kV) CT with probabilistic attenuation mapping for IGRT applications
    Pearson, Erik
    Pan, Xiaochuan
    Pelizzari, Charles
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [39] Dual-energy CT in early acute pancreatitis: improved detection using iodine quantification
    Martin, Simon S.
    Trapp, Franziska
    Wichmann, Julian L.
    Albrecht, Moritz H.
    Lenga, Lukas
    Durden, James
    Booz, Christian
    Vogl, Thomas J.
    D'Angelo, Tommaso
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (05) : 2226 - 2232
  • [40] Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
    Liang, Hongwei
    Zhou, Yang
    Zheng, Qiao
    Yan, Gaowu
    Liao, Hongfan
    Du, Silin
    Zhang, Xiaohui
    Lv, Fajin
    Zhang, Zhiwei
    Li, Yong-mei
    [J]. INSIGHTS INTO IMAGING, 2022, 13 (01)