Hydrophilic Interaction Liquid Chromatography-Electrospray Ionization Mass Spectrometry for Therapeutic Drug Monitoring of Metformin and Rosuvastatin in Human Plasma

被引:12
|
作者
Antonopoulos, Nikolaos [1 ]
Machairas, Giorgos [1 ]
Migias, George [2 ]
Vonaparti, Ariadni [3 ]
Brakoulia, Vasiliki [1 ]
Pistos, Constantinos [4 ]
Gennimata, Dimitra [5 ]
Panderi, Irene [1 ]
机构
[1] Univ Athens, Sch Pharm, Div Pharmaceut Chem, Lab Pharmaceut Anal, Athens 15771, Greece
[2] Gen Hosp Athens Alexandra, 80 Vas Sofias Ave, Athens 11528, Greece
[3] Qatar Doping Anal Lab, Sports City Rd,POB 27775, Doha, Qatar
[4] West Chester Univ, Dept Chem, W Chester, PA 19383 USA
[5] Gen Hosp Korgialenio Benakio Natl Red Cross, Erithrou Stavrou 1, Athens 11526, Greece
来源
MOLECULES | 2018年 / 23卷 / 07期
关键词
rosuvastatin; metformin; HILIC; LC-MS; therapeutic drug monitoring; N-DESMETHYL ROSUVASTATIN; SOLID-PHASE EXTRACTION; QUANTITATIVE-DETERMINATION; LC-MS/MS; HEALTHY-VOLUNTEERS; ANTIDIABETIC DRUGS; BIOLOGICAL-FLUIDS; QUANTIFICATION; VALIDATION; HYDROCHLORIDE;
D O I
10.3390/molecules23071548
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this work a hydrophilic interaction liquid chromatography/positive ion electrospray mass spectrometric assay (HILIC/ESI-MS) has been developed and fully validated for the quantitation of metformin and rosuvastatin in human plasma. Sample preparation involved the use of 100 mu L of human plasma, following protein precipitation and filtration. Metformin, rosuvastatin and 4-[2-(propylamino) ethyl] indoline 2 one hydrochloride (internal standard) were separated by using an X-Bridge-HILIC BEH analytical column (150.0 x 2.1 mm i.d., particle size 3.5 mu m) with isocratic elution. A mobile phase consisting of 12% (v/v) 15 mM ammonium formate water solution in acetonitrile was used for the separation and pumped at a flow rate of 0.25 mL min(-1). The linear range of the assay was 100 to 5000 ng mL(-1) and 2 to 100 ng mL(-1) for metformin and rosuvastatin, respectively. The current HILIC-ESI/MS method allows for the accurate and precise quantitation of metformin and rosuvastatin in human plasma with a simple sample preparation and a short a chromatographic run time (less than 15 min). Plasma samples from eight patients were further analysed proving the capability of the proposed method to support a wide range of clinical studies.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [41] Lansoprazole quantification in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Oliveira, CH
    Barrientos-Astigarraga, RE
    Abib, E
    Mendes, GD
    da Silva, DR
    de Nucci, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (02): : 453 - 459
  • [42] Determination of tetrabromobisphenol A in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry
    Hayama, T
    Yoshida, H
    Onimaru, S
    Yonekura, S
    Kuroki, H
    Todoroki, K
    Nohta, H
    Yamaguchi, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01): : 131 - 136
  • [43] Quantitation of Armillarisin A in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Wang, Yan
    Wang, Yingwu
    Li, Pengfei
    Tang, Yunbiao
    Fawcett, J. Paul
    Gu, Jingkai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) : 1860 - 1863
  • [44] Quantification of acarbose in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Raut, BB
    Kolte, BL
    Deo, AA
    Bagool, MA
    Shinde, DB
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2004, 27 (11) : 1759 - 1768
  • [45] Determination of herbicides and a metabolite in human urine by liquid chromatography-electrospray ionization mass spectrometry
    Pozzebon, JM
    Vilegas, W
    Jardim, ICSF
    JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) : 375 - 380
  • [46] Optimization strategy for liquid chromatography-electrospray ionization mass spectrometry methods
    Moberg, M
    Bylund, D
    Danielsson, R
    Markides, K
    ANALYST, 2000, 125 (11) : 1970 - 1976
  • [47] Analysis of corticosteroids in hair by Liquid chromatography-electrospray ionization mass spectrometry
    Bévalot, F
    Gaillard, Y
    Lhermitte, MA
    Pépin, G
    JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02): : 227 - 236
  • [48] Therapeutic monitoring of tacrolimus concentrations in blood: Semi-automated extraction and liquid chromatography-electrospray ionization mass spectrometry
    Lensmeyer, GL
    Poquette, MA
    THERAPEUTIC DRUG MONITORING, 2001, 23 (03) : 239 - 249
  • [49] High-performance liquid chromatography-electrospray ionization mass spectrometry determination of sodium ferulate in human plasma
    Yang, Cheng
    Tian, Yuan
    Zhang, Zunjian
    Xu, Fengguo
    Chen, Yun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (03) : 945 - 950
  • [50] Determination of finasteride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry with flow rate gradient
    Yuan, Lihua
    Ding, Meijuan
    Ma, Jing
    Xu, Jinhui
    Wu, Xiaoli
    Feng, Jing
    Shen, Fei
    Zhou, Xuemin
    EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 2011, 35 (3-4) : 137 - 146