Hydrophilic Interaction Liquid Chromatography-Electrospray Ionization Mass Spectrometry for Therapeutic Drug Monitoring of Metformin and Rosuvastatin in Human Plasma

被引:12
|
作者
Antonopoulos, Nikolaos [1 ]
Machairas, Giorgos [1 ]
Migias, George [2 ]
Vonaparti, Ariadni [3 ]
Brakoulia, Vasiliki [1 ]
Pistos, Constantinos [4 ]
Gennimata, Dimitra [5 ]
Panderi, Irene [1 ]
机构
[1] Univ Athens, Sch Pharm, Div Pharmaceut Chem, Lab Pharmaceut Anal, Athens 15771, Greece
[2] Gen Hosp Athens Alexandra, 80 Vas Sofias Ave, Athens 11528, Greece
[3] Qatar Doping Anal Lab, Sports City Rd,POB 27775, Doha, Qatar
[4] West Chester Univ, Dept Chem, W Chester, PA 19383 USA
[5] Gen Hosp Korgialenio Benakio Natl Red Cross, Erithrou Stavrou 1, Athens 11526, Greece
来源
MOLECULES | 2018年 / 23卷 / 07期
关键词
rosuvastatin; metformin; HILIC; LC-MS; therapeutic drug monitoring; N-DESMETHYL ROSUVASTATIN; SOLID-PHASE EXTRACTION; QUANTITATIVE-DETERMINATION; LC-MS/MS; HEALTHY-VOLUNTEERS; ANTIDIABETIC DRUGS; BIOLOGICAL-FLUIDS; QUANTIFICATION; VALIDATION; HYDROCHLORIDE;
D O I
10.3390/molecules23071548
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this work a hydrophilic interaction liquid chromatography/positive ion electrospray mass spectrometric assay (HILIC/ESI-MS) has been developed and fully validated for the quantitation of metformin and rosuvastatin in human plasma. Sample preparation involved the use of 100 mu L of human plasma, following protein precipitation and filtration. Metformin, rosuvastatin and 4-[2-(propylamino) ethyl] indoline 2 one hydrochloride (internal standard) were separated by using an X-Bridge-HILIC BEH analytical column (150.0 x 2.1 mm i.d., particle size 3.5 mu m) with isocratic elution. A mobile phase consisting of 12% (v/v) 15 mM ammonium formate water solution in acetonitrile was used for the separation and pumped at a flow rate of 0.25 mL min(-1). The linear range of the assay was 100 to 5000 ng mL(-1) and 2 to 100 ng mL(-1) for metformin and rosuvastatin, respectively. The current HILIC-ESI/MS method allows for the accurate and precise quantitation of metformin and rosuvastatin in human plasma with a simple sample preparation and a short a chromatographic run time (less than 15 min). Plasma samples from eight patients were further analysed proving the capability of the proposed method to support a wide range of clinical studies.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [31] Determination of green tea catechins in human plasma using liquid chromatography-electrospray ionization mass spectrometry
    Masukawa, Y
    Matsui, Y
    Shimizu, N
    Kondou, N
    Endou, H
    Kuzukawa, M
    Hase, T
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 834 (1-2): : 26 - 34
  • [32] Measurement of the novel decapeptide cetrorelix in human plasma and urine by liquid chromatography-electrospray ionization mass spectrometry
    Niwa, M
    Enomoto, K
    Yamashita, K
    JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2): : 245 - 253
  • [33] A Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry Method for Quantitation of Aripiprazole in Human Plasma
    Lin, Shen-Nan
    Lamm, Lolita
    Newton, Thomas F.
    Reid, Malcolm S.
    Moody, David E.
    Foltz, Rodger L.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2009, 33 (05) : 237 - 242
  • [34] Determination of oxatomide in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry
    She, Xiaodong
    Wu, Lili
    Wei, Huilin
    Liu, Weida
    Chen, Yun
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 746 - 752
  • [35] Liquid chromatography-electrospray ionization tandem mass spectrometry for the quantification of styraxlignolide A in rat plasma
    Ji, Hye Y.
    Oh, Sei-Ryang
    Lee, Hyeong-Kyu
    Na, Dong H.
    Lee, Hye S.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (15) : 1828 - 1833
  • [36] Liquid Chromatography-Electrospray Ionization Mass Spectrometry Method for Determination of Protopanaxadiol in Rat Plasma
    WU Yi1
    2. College of Life Science
    3. School of Chemistry and Life Science
    4. Jilin Provincial Corps Hospital
    Chemical Research in Chinese Universities, 2009, 25 (05) : 673 - 676
  • [37] Liquid Chromatography-Electrospray Ionization Mass Spectrometry Method for Determination of Protopanaxadiol in Rat Plasma
    Wu Yi
    Teng Guo-sheng
    Liang Yong-tao
    Zhong Da-fang
    Liu Bing
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2009, 25 (05) : 673 - 676
  • [38] Determination of metformin and other biguanides in forensic whole blood samples by hydrophilic interaction liquid chromatography-electrospray tandem mass spectrometry
    Sorensen, Lambert K.
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (01) : 1 - 5
  • [39] Simultaneous determination of melamine and related compounds by hydrophilic interaction liquid chromatography-electrospray mass spectrometry
    Xia, Jingen
    Zhou, Naiyuan
    Zhou, Cong
    Chen, Bo
    Wu, Yongning
    Yao, Shouzhuo
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (17-18) : 2688 - 2697
  • [40] Lisinopril quantification in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Padua, AAF
    Barrientos-Astigarraga, RE
    Rezende, VM
    Mendes, GD
    De Nucci, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 211 - 216