Hydrophilic Interaction Liquid Chromatography-Electrospray Ionization Mass Spectrometry for Therapeutic Drug Monitoring of Metformin and Rosuvastatin in Human Plasma

被引:12
|
作者
Antonopoulos, Nikolaos [1 ]
Machairas, Giorgos [1 ]
Migias, George [2 ]
Vonaparti, Ariadni [3 ]
Brakoulia, Vasiliki [1 ]
Pistos, Constantinos [4 ]
Gennimata, Dimitra [5 ]
Panderi, Irene [1 ]
机构
[1] Univ Athens, Sch Pharm, Div Pharmaceut Chem, Lab Pharmaceut Anal, Athens 15771, Greece
[2] Gen Hosp Athens Alexandra, 80 Vas Sofias Ave, Athens 11528, Greece
[3] Qatar Doping Anal Lab, Sports City Rd,POB 27775, Doha, Qatar
[4] West Chester Univ, Dept Chem, W Chester, PA 19383 USA
[5] Gen Hosp Korgialenio Benakio Natl Red Cross, Erithrou Stavrou 1, Athens 11526, Greece
来源
MOLECULES | 2018年 / 23卷 / 07期
关键词
rosuvastatin; metformin; HILIC; LC-MS; therapeutic drug monitoring; N-DESMETHYL ROSUVASTATIN; SOLID-PHASE EXTRACTION; QUANTITATIVE-DETERMINATION; LC-MS/MS; HEALTHY-VOLUNTEERS; ANTIDIABETIC DRUGS; BIOLOGICAL-FLUIDS; QUANTIFICATION; VALIDATION; HYDROCHLORIDE;
D O I
10.3390/molecules23071548
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this work a hydrophilic interaction liquid chromatography/positive ion electrospray mass spectrometric assay (HILIC/ESI-MS) has been developed and fully validated for the quantitation of metformin and rosuvastatin in human plasma. Sample preparation involved the use of 100 mu L of human plasma, following protein precipitation and filtration. Metformin, rosuvastatin and 4-[2-(propylamino) ethyl] indoline 2 one hydrochloride (internal standard) were separated by using an X-Bridge-HILIC BEH analytical column (150.0 x 2.1 mm i.d., particle size 3.5 mu m) with isocratic elution. A mobile phase consisting of 12% (v/v) 15 mM ammonium formate water solution in acetonitrile was used for the separation and pumped at a flow rate of 0.25 mL min(-1). The linear range of the assay was 100 to 5000 ng mL(-1) and 2 to 100 ng mL(-1) for metformin and rosuvastatin, respectively. The current HILIC-ESI/MS method allows for the accurate and precise quantitation of metformin and rosuvastatin in human plasma with a simple sample preparation and a short a chromatographic run time (less than 15 min). Plasma samples from eight patients were further analysed proving the capability of the proposed method to support a wide range of clinical studies.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [21] Determination of cymipristone in human plasma by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Jiang, Bo
    Ruan, Zourong
    Lou, Honggang
    Yuan, Hong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (7-8): : 719 - 723
  • [22] Determination of ranolazine in rat plasma by liquid chromatography-electrospray ionization mass spectrometry
    Zhong, J
    Liu, XQ
    Chen, Y
    Zhao, XP
    Wang, YS
    Wang, GJ
    CHROMATOGRAPHIA, 2006, 63 (3-4) : 123 - 127
  • [23] Determination of alliin in rat plasma by liquid chromatography-electrospray ionization mass spectrometry
    Shin, YG
    Matsuura, H
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (09) : 1331 - 1338
  • [24] Simultaneous quantification of selective serotonin reuptake inhibitors and metabolites in human plasma by liquid chromatography-electrospray mass spectrometry for therapeutic drug monitoring
    Ansermot, Nicolas
    Brawand-Amey, Marlyse
    Eap, Chin B.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 885 : 117 - 130
  • [25] Quantitation of salbutamol in human urine by liquid chromatography-electrospray ionization mass spectrometry
    Zhang, JL
    Xu, YX
    Di, X
    Wu, MT
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2): : 328 - 332
  • [26] Plasma lipid analysis by hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Sonomura, Kazuhiro
    Kudoh, Shinobu
    Sato, Taka-Aki
    Matsuda, Fumihiko
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (12) : 2033 - 2037
  • [27] Quantification of cardiolipin by liquid chromatography-electrospray ionization mass spectrometry
    Garrett, Teresa A.
    Kordestani, Reza
    Raetz, Christian R. H.
    LIPIDOMICS AND BIOACTIVE LIPIDS: SPECIALIZED ANALYTICAL METHODS AND LIPIDS IN DISEASE, 2007, 433 : 213 - 230
  • [28] Hydrophilic interaction liquid chromatography-electrospray ionization-tandem mass spectrometry of a complex mixture of native and oxidized phospholipids
    Losito, I.
    Facchini, L.
    Diomede, S.
    Conte, E.
    Megli, F. M.
    Cataldi, T. R. I.
    Palmisano, F.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1422 : 194 - 205
  • [29] Determination of raltitrexed in human plasma by high performance liquid chromatography-electrospray ionization-mass spectrometry
    Hu, Jingjing
    Ding, Li
    Song, Qinxin
    Gao, Ying
    Qing, Shukui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 147 - 153
  • [30] Determination of the carboxylic acid metabolite of clopidogrel in human plasma by liquid chromatography-electrospray ionization mass spectrometry
    Mitakos, A
    Panderi, I
    ANALYTICA CHIMICA ACTA, 2004, 505 (01) : 107 - 114