A comparison of the Macintosh laryngoscope, McGrath video laryngoscope, and Pentax Airway Scope in paediatric nasotracheal intubation

被引:11
|
作者
Yoo, Ji Young [1 ]
Chae, Yun Jeong [1 ]
Lee, Young Bok [2 ]
Kim, Sujin [2 ]
Lee, Jaemoon [2 ]
Kim, Dae Hee [1 ]
机构
[1] Ajou Univ, Sch Med, Dept Anesthesiol & Pain Med, Suwon, South Korea
[2] Yonsei Univ, Wonju Coll Med, Dept Anesthesiol & Pain Med, Wonju, South Korea
来源
SCIENTIFIC REPORTS | 2018年 / 8卷
关键词
TRACHEAL TUBE; GLIDESCOPE(R) VIDEOLARYNGOSCOPY; NASAL INTUBATION; CUFF INFLATION;
D O I
10.1038/s41598-018-35857-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We evaluated the performance of the McGrath video laryngoscope and Pentax Airway Scope in comparison with the Macintosh laryngoscope for nasotracheal intubation in paediatric patients. For this, 108 patients were enrolled in an open-label, randomized controlled trial. Patients were randomly allocated to one of three groups based on use of the Macintosh laryngoscope, McGrath video laryngoscope, or Pentax Airway Scope. Time to intubation, the intubation difficulty, and the quality of navigation were compared among groups. The median nasotracheal intubation time [interquartile range] in the Macintosh group (33.5 [28.3-39.8] s) was significantly shorter than those of the McGrath (39.0 [32.0-43.0] s) and Pentax groups (43.0 [35.0-52.0] s). The difficulty of nasotracheal intubation was similar among all groups. When navigating and aligning the tube from the oropharynx into the glottic inlet, the cuff inflation method was required in significantly fewer patients for the Macintosh group (11.1%) than for the McGrath (48.6%) and Pentax (51.4%) groups. Thus, compared to the McGrath video laryngoscope and Pentax Airway Scope, the Macintosh laryngoscope allowed shorter nasotracheal intubation times and better facilitated tracheal navigation, requiring less use of the cuff inflation method to navigate the tracheal tube into the glottic inlet.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A comparison of the Macintosh laryngoscope, McGrath video laryngoscope, and Pentax Airway Scope in paediatric nasotracheal intubation
    Ji Young Yoo
    Yun Jeong Chae
    Young Bok Lee
    Sujin Kim
    Jaemoon Lee
    Dae Hee Kim
    Scientific Reports, 8
  • [2] A comparison of McGrath video laryngoscope and Macintosh laryngoscope during nasotracheal intubation: A randomised controlled study
    Gangishetty, Alekhya
    Jonnavithula, Nirmala
    Geetha, Singam
    Muthyala, Harshini
    Peetha, Hareesh
    JOURNAL OF PERIOPERATIVE PRACTICE, 2024, 34 (12) : 378 - 383
  • [3] Comparison of the Pentax-AWS Airway Scope with the Macintosh laryngoscope for nasotracheal intubation: a randomized, prospective study
    Suzuki, Akihiro
    Onodera, Yoshiko
    Mitamura, Sayuri M.
    Mamiya, Keiko
    Kunisawa, Takayuki
    Takahata, Osamu
    Henderson, John J.
    Iwasaki, Hiroshi
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (07) : 561 - 565
  • [4] Randomized comparison of McGrath MAC videolaryngoscope, Pentax Airway Scope, and Macintosh direct laryngoscope for nasotracheal intubation in patients with manual in-line stabilization
    Roh, Go Un
    Kwak, Hyun Jeong
    Lee, Kyung Cheon
    Lee, Sun Young
    Kim, Jong Yeop
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2019, 66 (10): : 1213 - 1220
  • [5] A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope
    Choi, Hyun Young
    Oh, Young Min
    Kang, Gu Hyun
    Kang, Hyunggoo
    Jang, Yong Soo
    Kim, Wonhee
    Kim, Euichung
    Cho, Young Soon
    Choi, Hyukjoong
    Kim, Hyunjong
    Kim, Gyoung Yong
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [6] Comparison of the Pentax Airway Scope® and McGrath® Videolaryngoscope with the Macintosh laryngoscope in tracheal intubation by anaesthetists unfamiliar with videolaryngoscopes: a manikin study
    Sharma, D. -J.
    Weightman, W. M.
    Travis, A.
    ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (01) : 39 - 42
  • [7] Tracheal intubation with restricted access: a randomised comparison of the Pentax-Airway Scope and Macintosh laryngoscope in a manikin
    Asai, T.
    ANAESTHESIA, 2009, 64 (10) : 1114 - 1117
  • [8] Performance of a Pentax-Airway scope and a Macintosh laryngoscope for difficult intubation in a manikin study
    Xue, F. S.
    Liao, X.
    Yuan, Y. J.
    Liu, J. H.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (07) : 900 - 901
  • [9] Randomized comparison of the Pentax AirWay Scope and Macintosh laryngoscope for tracheal intubation in patients with obstructive sleep apnoea
    Kim, M. K.
    Park, S. W.
    Lee, J. W.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (04) : 662 - 666
  • [10] The usefulness of the McGrath MAC laryngoscope in comparison with Airwayscope and Macintosh laryngoscope during routine nasotracheal intubation: a randomaized controlled trial
    Aiji Sato (Boku)
    Kazuya Sobue
    Eisuke Kako
    Naoko Tachi
    Yoko Okumura
    Mayuko Kanazawa
    Mayumi Hashimoto
    Jun Harada
    BMC Anesthesiology, 17