Randomized comparison of the Pentax AirWay Scope and Macintosh laryngoscope for tracheal intubation in patients with obstructive sleep apnoea

被引:10
|
作者
Kim, M. K. [1 ]
Park, S. W. [1 ]
Lee, J. W. [2 ,3 ]
机构
[1] Kyung Hee Univ, Sch Med, Dept Anesthesiol & Pain Med, Seoul 130872, South Korea
[2] Cardiovasc Hosp, Div Anesthesiol & Pain Med, Seoul, South Korea
[3] Yonsei Univ, Coll Med, Dept Anesthesiol & Pain Med, Seoul 120752, South Korea
关键词
intubation; intratracheal; laryngoscopes; sleep apnoea; obstructive; CERVICAL-SPINE IMMOBILIZATION; DIFFICULT INTUBATION; ENDOTRACHEAL INTUBATION; VIDEO LARYNGOSCOPE; GLIDESCOPE(R); PENTAX-AWS(R); VIDEOLARYNGOSCOPE; AIRWAYSCOPE(R); AWS;
D O I
10.1093/bja/aet201
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Patients with obstructive sleep apnoea (OSA) can often present difficulties in intubation. This study aimed to compare the efficacy of the Pentax AirWay Scope (AWS) with that of the Macintosh laryngoscope for tracheal intubation in patients with OSA. Methods. Forty-six patients undergoing uvulopalatopharyngoplasty were randomly allocated to tracheal intubation with either the Macintosh laryngoscope or the Pentax AWS. In all patients, intubation was performed by one of two anaesthetists experienced with both devices. The primary and secondary endpoints of this study were the intubation difficulty scale (IDS) score and success/failure and duration of the first successful intubation attempt. Results. With the Pentax AWS, tracheal intubation was successful on the first attempt in all patients whereas four patients required repeated attempts at intubation with the Macintosh laryngoscope. The IDS score was significantly lower using the Pentax AWS and glottic exposure was better (the Cormack and Lehane grade 1 in all patients vs grade 2 or higher in all patients, P<0.0001). Average duration of successful intubation was shorter (12.9 vs 29.9 s, P=0.0002), and fewer manoeuvres were needed to improve the glottic exposure (0 in all patients vs 1 or more in 16 patients, P<0.0001) with the Pentax AWS, compared with the Macintosh laryngoscope. Conclusions. In this study of patients with OSA, tracheal intubation by experienced anaesthetists was facilitated using the Pentax AWS compared with the Macintosh laryngoscope.
引用
收藏
页码:662 / 666
页数:5
相关论文
共 50 条
  • [1] Randomized comparison of the airway scope and the macintosh laryngoscope for the tracheal intubation in manikin study
    Yuasa, Haruyuki
    Yokoyama, Hiroyuki
    Yonemoto, Naohiro
    Kada, Akiko
    Kasahara, Yoichiro
    Koga, Yoshihisa
    Nonogi, Hiroshi
    [J]. CIRCULATION, 2007, 116 (16) : 944 - 944
  • [2] Tracheal intubation with restricted access: a randomised comparison of the Pentax-Airway Scope and Macintosh laryngoscope in a manikin
    Asai, T.
    [J]. ANAESTHESIA, 2009, 64 (10) : 1114 - 1117
  • [3] A comparison of the Macintosh laryngoscope, McGrath video laryngoscope, and Pentax Airway Scope in paediatric nasotracheal intubation
    Ji Young Yoo
    Yun Jeong Chae
    Young Bok Lee
    Sujin Kim
    Jaemoon Lee
    Dae Hee Kim
    [J]. Scientific Reports, 8
  • [4] A comparison of the Macintosh laryngoscope, McGrath video laryngoscope, and Pentax Airway Scope in paediatric nasotracheal intubation
    Yoo, Ji Young
    Chae, Yun Jeong
    Lee, Young Bok
    Kim, Sujin
    Lee, Jaemoon
    Kim, Dae Hee
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [6] Comparison of the Pentax-AWS Airway Scope with the Macintosh laryngoscope for nasotracheal intubation: a randomized, prospective study
    Suzuki, Akihiro
    Onodera, Yoshiko
    Mitamura, Sayuri M.
    Mamiya, Keiko
    Kunisawa, Takayuki
    Takahata, Osamu
    Henderson, John J.
    Iwasaki, Hiroshi
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (07) : 561 - 565
  • [7] Comparison of tracheal intubation with the Airway Scope and Macintosh laryngoscope in the lateral position
    Xue, Fu-Shan
    Liao, Xu
    Wang, Qiang
    Yuan, Yu-Jing
    Xiong, Jun
    Liu, Jian-Hua
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (06) : 464 - 465
  • [8] Airway Scope and Macintosh Laryngoscope for Tracheal Intubation in Patients Lying on the Ground
    Komatsu, Ryu
    Kamata, Kotoe
    Sessler, Daniel I.
    Ozaki, Makoto
    [J]. ANESTHESIA AND ANALGESIA, 2010, 111 (02): : 427 - 431
  • [9] Comparison of three videolaryngoscopes: Pentax Airway Scope, C-MAC™, Glidescope® vs the Macintosh laryngoscope for tracheal intubation
    Teoh, W. H. L.
    Saxena, S.
    Shah, M. K.
    Sia, A. T. H.
    [J]. ANAESTHESIA, 2010, 65 (11) : 1126 - 1132
  • [10] Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin study
    Nobuyasu Komasawa
    Ryusuke Ueki
    Hajime Nomura
    Motoi Itani
    Yoshiroh Kaminoh
    [J]. Journal of Anesthesia, 2010, 24 : 306 - 308